Meredith Hubbard
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Meredith Hubbard has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Luigi Bruno
Dipartimento di Ingegneria Meccanica, Energetica e Gestionale, Università della Calabria, 87036 Rende, Italy
2 shared publications - Massimo A. Fazio
Department of Ophthalmology and Vision Science, School of Medicine, The University of Alabama at Birmingham, Birmingham, AL, United States
2 shared publications Christopher A. Girkin
Univ Alabama, Dept Ophthalmol & Visual Sci, Birmingham, CA 35294 USA
1 shared publication- Christopher A. Girkin
From the Hamilton Glaucoma Center, Shiley Eye Institute, Viterbi Family Department of Ophthalmology (G.G., S.M., T.N., L.M.Z., R.N.W.), University of California San Diego, La Jolla, California, USA
1 shared publication Gianfranco Bianco
Univ Alabama, Dept Ophthalmol & Visual Sci, Birmingham, CA 35294 USA
1 shared publication- Gianfranco Bianco
Department of Ophthalmology and Visual Sciences, University of Alabama at Birmingham, Birmingham AL, USA
1 shared publication
Latest Publications
- Open Access
The Effect of Negative Pressure on IOP in the Living Human Eye
To quantify the effect of negative pressure applied to the anterior surface of the eye on absolute IOP. Subjects Participants, and/or Controls. Three eyes from three research-consented brain-dead organ donors. Methods Air-tight goggles connected to a negative pressure (NP) pump (Mercury Multi-pressure Dial (MPD); Equinox Ophthalmic, Inc., CA) were tested on three research consented brain-dead organ donors. The MPD was set to generate a vacuum of -20mmHg. A baseline IOP of 10, 20, and 30mmHg was sequentially set by adjusting the height of a balanced salt solution bottle connected to the cornea through a 20G needle. IOP was manually annotated at time = 0s, right before turning on the vacuum pump; after a few seconds with the vacuum pump ON; at 60s; at 120s, right before turning the pump OFF; at 240s with the pump OFF (recovery). Three repetitions per each test at varying baseline IOP were taken for a total of nine series of measures per eye. Main Outcome Measures IOP change with exposure to NP. Results Eye1 and 3 showed an immediate reduction in IOP at all baselines immediately following activation of the MPD NP pump; Eye2 showed an opposite response to NP. Eye1 and 3 showed a reduction in IOP at all baselines with NP pump ON for 60s and 120s, while Eye 2 showed a consistent increase in IOP. After 120s from turning NP OFF (time=240s), IOP partially recovered to its baseline in all eyes. Conclusions This study is the first to evaluate changes in manometrically-measured intracameral IOP due to NP applied to the ocular surface in living conditions. The inconsistent response of IOP following exposure to negative pressure warrants further investigations on the mechanism underlaying IOP lowering by NP.
Open AccessThe Effect of Negative Pressure on IOP in the Living Human Eye
To quantify the effect of negative pressure applied to the anterior surface of the eye on absolute IOP. Subjects Participants, and/or Controls. Three eyes from three research-consented brain-dead organ donors. Methods Air-tight goggles connected to a negative pressure (NP) pump (Mercury Multi-pressure Dial (MPD); Equinox Ophthalmic, Inc., CA) were tested on three research consented brain-dead organ donors. The MPD was set to generate a vacuum of -20mmHg. A baseline IOP of 10, 20, and 30mmHg was sequentially set by adjusting the height of a balanced salt solution bottle connected to the cornea through a 20G needle. IOP was manually annotated at time = 0s, right before turning on the vacuum pump; after a few seconds with the vacuum pump ON; at 60s; at 120s, right before turning the pump OFF; at 240s with the pump OFF (recovery). Three repetitions per each test at varying baseline IOP were taken for a total of nine series of measures per eye. Main Outcome Measures IOP change with exposure to NP. Results Eye1 and 3 showed an immediate reduction in IOP at all baselines immediately following activation of the MPD NP pump; Eye2 showed an opposite response to NP. Eye1 and 3 showed a reduction in IOP at all baselines with NP pump ON for 60s and 120s, while Eye 2 showed a consistent increase in IOP. After 120s from turning NP OFF (time=240s), IOP partially recovered to its baseline in all eyes. Conclusions This study is the first to evaluate changes in manometrically-measured intracameral IOP due to NP applied to the ocular surface in living conditions. The inconsistent response of IOP following exposure to negative pressure warrants further investigations on the mechanism underlaying IOP lowering by NP.