LXLiang Xian

Liang Xian

*This is an algorithmically generated author record based on publicly available information.

Liang Xian has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Universal Short-Circuit Detection and Protection Scheme for Series-Connected SiC MOSFETs

    by Ye Zhou, Liang Xian, Xu Wang, Dan Yang

    Stacking SiC mosfets in series is an effective approach to enhance voltage rating and simplify topologies of high-power converters. Beyond the dynamic voltage balancing during normal switching operations, short-circuit (SC) detection and protection are equally critical. Discrepancies in gate drive timing and inherent mismatches in the I–V characteristics among series-connected devices not only complicate SC detection but also induce imbalanced voltage sharing with elevated current, posing a significant challenge for conventional SC detection circuits and snubbers. To solve these issues, a novel SC detector (SCD) and soft turn-off (STO) circuit designed for series-connected SiC mosfets are proposed in this article. Based on the voltage slope of the entire power stack, the SCD is compatible with both hard switching fault and fault under load (FUL) conditions. The STO circuit can be directly integrated into conventional concentrated clamping snubber. It can actively limit the current through each series-stacked SiC mosfet during an SC event, while balancing the fault energy distribution among devices and mitigating the risk of excessive power dissipation. The design guidelines as well as detailed selection principles for the components of each sub-circuit are specified. Furthermore, the performance of the proposed SC detection and protection scheme is experimentally verified based on the established test platform.

  • Decentralized Active Disturbance Rejection Control for Hybrid Energy Storage System in DC Microgrid

    by Zhipeng Li, Benfei Wang, Liang Xian, Mengfan Zhang, Qianwen Xu

    Nowadays, hybrid energy storage system (HESS) is a popular option to compensate for renewable energy fluctuations in the microgrid. The main advantages of HESS are that it can eliminate bus voltage fluctuations and maximize the strength of multifarious energy storage systems with different characteristics. Therefore, power allocation between different ESSs is a major issue for HESS. Moreover, the high integration of constant power loads brings instability issues to the dc microgrid. To address the above concerns, this article proposes a decentralized power sharing and stabilization method based on active disturbance rejection control (ADRC). First, an ADRC controller is proposed for a single ESS, where the system disturbance is estimated and compensated through an extended state observer (ESO). Thus, the dc-bus voltage is maintained. Second, an ADRC-based decentralized method for HESS is developed. ESO can estimate the output current of converters. Thus, the current sensors of the local controller can be reduced. Furthermore, the proposed method is extended into HESS with multiple batteries and SCs, which verifies its scalability. Stability analysis is performed to guarantee the large-signal stability of the whole system. At last, simulation and experimental have been conducted to verify the feasibility of the proposed method.


  • Higher Order Sliding Mode Observer Based Fast Composite Backstepping Control for HESS in DC Microgrids

    by Benfei Wang, Zhipeng Li, Hongru Fan, Xinmao Wan, Liang Xian, Mengfan Zhang, Qianwen Xu

    Hybrid energy storage system (HESS) is effective to compensate for fluctuation power in renewables and fast fluctuation loads in DC microgrids. To regulate DC bus voltage, a power management strategy is an essential issue. In the meantime, the increasing integration of constant power loads (CPLs) in DC microgrids brings great challenges to stable operation due to their negative incremental impedance. In this paper, a fast composite backstepping control (FBC) method is proposed for the HESS to achieve faster dynamics, smaller voltage variations, and large-signal stabilization. In the FBC method, a higher order sliding mode observer (HOSMO) is adopted to estimate the coupled disturbances. Furthermore, the FBC method is integrated with the droop control; so that the FBC-based decentralized power allocation (FBC-DPA) strategy for HESS in DC microgrids is developed. The proposed FBC method is designed based on the Lyapunov function to ensure its stability. Moreover, the design guidelines are provided to facilitate the application of the proposed method. Both simulation and experimental studies under different operating scenarios show that the proposed method achieves faster voltage recovery and smaller voltage variations than the conventional backstepping control method.


  • Variable Turn-OFF Gate Voltage Drive for Voltage Balancing of High-Speed SiC MOSFETs in Series-Connection

    by Ye Zhou, Liang Xian, Xu Wang

    Active gate drive with high accurate and self-adaptive closed-loop control is a promising approach to solving the imbalanced voltage problem of series-connected silicon carbide (SiC) mosfet s. However, due to the inherent time propagation mismatching between Si- and SiC-based devices, behavior adjustment through Si-based ICs during the switching transient takes at least tens of nanoseconds, which limits the minimum allowable turn- off time of each series unit. In this article, a novel active gate drive with a variable gate voltage regulator (GVR) is proposed. It uses a single P-channel mosfet to determine the connection timing of a precharged capacitor in series with the input capacitance in which way the switching transient of each device in the stack is adjustable. It is more advantageous when applied to the low-power SiC mosfet applications with relatively smaller external gate resistors. Two sampling and voltage balancing control circuits based on different processors are proposed for the GVR to adapt to different switching frequencies and costs. Its operational principle and design guidelines are specified and its performance on voltage balancing control is experimentally verified. Analytical assessment on switching losses and costs, compared with the previous work, is provided.


  • Active Gate Drive With Gate–Drain Discharge Compensation for Voltage Balancing in Series-Connected SiC MOSFETs

    by Ye Zhou, Xu Wang, Liang Xian, Dan Yang

    Imbalanced voltage sharing during the turn-off transient is a challenge for series-connected silicon carbide (SiC) MOSFET application. This article first discusses the influence of the gate-drain discharge deviation on the voltage imbalance ratio, and its primary causes are also presented and verified by LTspice simulation. Accordingly, a novel active gate drive, which aims to compensate the discharge difference between devices connected in series, is proposed and analyzed. By only using the original output of the driving IC, the proposed gate drive is realized by implementing an auxiliary circuit on the existing commercial gate drive. Therefore, unlike other active gate drives for balancing control, no extra isolations for power/signal are needed, and the number of the devices in series is unlimited. The auxiliary circuit includes three subcircuits as a high-bandwidth current sink for regulating switching performance, a relative low-frequency but reliable sampling and control circuit for closed-loop control, and a trigger combining the former and the latter. The operational principle and the design guideline for each part are presented in detail. Experimental results validate the performance of the proposed gate drive and its voltage balancing control algorithm.


  • 60 GHz Frequency Sharing Study between Fixed Service Systems and Small-Cell Systems with Modular Antenna Arrays

    by Joongheon Kim, Liang Xian, Reza Arefi, Ali S. Sadri

    This paper presents numerical simulation results in order to identify how much interference can be generated to a fixed service (FS) receiver from nearby small cell networks when the FS systems and small-cell systems are sharing a 60 GHz mmWave frequency band. For this 60 GHz frequency sharing study, two different scenarios are considered, i.e., the aggregation of interference into an FS receiver occurred by every transmission (i) from base stations (BSs) to their associated user elements (UEs); (ii) from UEs and their associated BSs. Moreover, 60 GHz mmWave specific propagation characteristics and attenuation factors are considered for more precise simulation study. The simulation results determine how much interference rejection is required to protect the operation of FS.


  • Open Access

    Exact steady‐state analysis in multiple‐input converters applied with diverse time‐sharing switching schemes

    by Liang Xian, Youyi Wang

    Time‐sharing switching (TSS) techniques are usually utilised in multiple‐input converters (MICs) to manage power sharing among inputs as well as output‐voltage regulation. The two most‐commonly‐used TSS schemes in practical MIC applications are trailing‐edge modulation (TEM) and interleaved dual‐edge modulation (IDEM), both of which containing abundant significant information on conduction sequence. Steady‐state analysis and computation help understand MICs' behaviour, being of high significance in both principal and practical researches. This study exhibits a general and exact methodology for computing and synthesising analytical expressions in a steady state of any kind of MIC topology, based upon analysis of segmented waveforms of common inductor current and output capacitor voltage. The derivation results are of high accuracy and generality, applicable for scenarios with arbitrary number of inputs in either continuous conduction mode or discontinuous conduction mode, and applied by either TEM‐based or IDEM‐based TSS schemes. Analytical and derivation details are addressed to the issues of multiple‐input buck converters, along with general procedures established for other MICs topologies, for example, multiple‐input buck–boost converters and multiple‐input single‐ended primary‐inductor converters. Case study on a dual‐input buck converter prototype, considering power dissipations and voltage drops on its components, is put forward for theoretical verification.