Kenneth W. Chow
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kenneth W. Chow has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Sammy Saab
Department of Medicine and Surgery, David Geffen School of Medicine at UCLA, Los Angeles, USA
2 shared publications - Sofiya Reicher
Department of Medicine, Harbor-UCLA Medical Center, Torrance, CA 90502, USA
2 shared publications - Viktor Eysselein
Department of Medicine, Harbor-UCLA Medical Center, Torrance, CA 90502, USA
2 shared publications - Aiden Hoyle
Department of Psychology, University of Amsterdam, The Netherlands
1 shared publication - Brandon Gisi
Division of Gastroenterology & Hepatology, Harbor-UCLA Medical Center, Torrance, CA
1 shared publication - Brittney Bs Ibrahim
Department of Medicine, University of California at Los Angeles, Los Angeles, California, USA
1 shared publication
Latest Publications
- Open Access
- 18 December 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (24) , 2854
Lumen-Apposing Metal Stents in the Management of Complex Pelvic Abscesses
Background: Lumen-apposing metal stents (LAMS) are utilized in a wide range of therapeutic gastrointestinal applications. We present our experience with LAMS-assisted drainage of complex pelvic abscesses at a large safety-net hospital. Methods: EUS-guided LAMS placements for pelvic abscesses from July 2020 to June 2024 were analyzed. Data were collected on patient demographics, procedure indications, fluid collection size, stent characteristics, stent dwell time, and complications. All cases underwent multidisciplinary review with Surgery and Interventional Radiology (IR) prior to LAMS-assisted drainage; all were deemed not amenable to drainage by IR. Results: Eleven patients underwent EUS-guided drainage of complex pelvic abscesses with cautery-enhanced LAMS. Diverticulitis was the most common cause of abscesses (n = 6; 55%). The average time from presentation to drainage was 7 days (1–18). The average abscess size was 7.2 cm (3.9–12.0 cm). The most common LAMS size was 15 mm × 10 mm; each was placed through the left colon and rectum with both technical and clinical success. All abscesses completely resolved with a mean stent dwell time of 28 days (17–42 days). After stent removal, the fistula was not routinely closed. No complications such as stent migration, bleeding, or perforation occurred. There were no recurrences and no patients required additional surgical or IR procedures with a mean follow-up of 25 weeks (SD 35.6). Conclusions: Adequate drainage is the cornerstone of pelvic abscess management, but IR or surgical access can be challenging, with inadequate drainage and prolonged hospitalization leading to significant morbidity. In our experience, EUS-guided, LAMS-assisted drainage provides a safe and effective alternative for managing pelvic abscesses.
- 18 December 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (24) , 2854
Open AccessLumen-Apposing Metal Stents in the Management of Complex Pelvic Abscesses
Background: Lumen-apposing metal stents (LAMS) are utilized in a wide range of therapeutic gastrointestinal applications. We present our experience with LAMS-assisted drainage of complex pelvic abscesses at a large safety-net hospital. Methods: EUS-guided LAMS placements for pelvic abscesses from July 2020 to June 2024 were analyzed. Data were collected on patient demographics, procedure indications, fluid collection size, stent characteristics, stent dwell time, and complications. All cases underwent multidisciplinary review with Surgery and Interventional Radiology (IR) prior to LAMS-assisted drainage; all were deemed not amenable to drainage by IR. Results: Eleven patients underwent EUS-guided drainage of complex pelvic abscesses with cautery-enhanced LAMS. Diverticulitis was the most common cause of abscesses (n = 6; 55%). The average time from presentation to drainage was 7 days (1–18). The average abscess size was 7.2 cm (3.9–12.0 cm). The most common LAMS size was 15 mm × 10 mm; each was placed through the left colon and rectum with both technical and clinical success. All abscesses completely resolved with a mean stent dwell time of 28 days (17–42 days). After stent removal, the fistula was not routinely closed. No complications such as stent migration, bleeding, or perforation occurred. There were no recurrences and no patients required additional surgical or IR procedures with a mean follow-up of 25 weeks (SD 35.6). Conclusions: Adequate drainage is the cornerstone of pelvic abscess management, but IR or surgical access can be challenging, with inadequate drainage and prolonged hospitalization leading to significant morbidity. In our experience, EUS-guided, LAMS-assisted drainage provides a safe and effective alternative for managing pelvic abscesses.
- Open Access
- 16 June 2024
- Published by Baishideng Publishing Group Inc. in World Journal of Gastrointestinal Endoscopy
- Vol. 16 (6) , 335-342
Long-term impact of artificial intelligence on colorectal adenoma detection in high-risk colonoscopy
BACKGROUND Improved adenoma detection rate (ADR) has been demonstrated with artificial intelligence (AI)-assisted colonoscopy. However, data on the real-world application of AI and its effect on colorectal cancer (CRC) screening outcomes is limited. AIM To analyze the long-term impact of AI on a diverse at-risk patient population undergoing diagnostic colonoscopy for positive CRC screening tests or symptoms. METHODS AI software (GI Genius, Medtronic) was implemented into the standard procedure protocol in November 2022. Data was collected on patient demographics, procedure indication, polyp size, location, and pathology. CRC screening outcomes were evaluated before and at different intervals after AI introduction with one year of follow-up. RESULTS We evaluated 1008 colonoscopies (278 pre-AI, 255 early post-AI, 285 established post-AI, and 190 late post-AI). The ADR was 38.1% pre-AI, 42.0% early post-AI (P = 0.77), 40.0% established post-AI (P = 0.44), and 39.5% late post-AI (P = 0.77). There were no significant differences in polyp detection rate (PDR, baseline 59.7%), advanced ADR (baseline 16.2%), and non-neoplastic PDR (baseline 30.0%) before and after AI introduction. CONCLUSION In patients with an increased pre-test probability of having an abnormal colonoscopy, the current generation of AI did not yield enhanced CRC screening metrics over high-quality colonoscopy. Although the potential of AI in colonoscopy is undisputed, current AI technology may not universally elevate screening metrics across all situations and patient populations. Future studies that analyze different AI systems across various patient populations are needed to determine the most effective role of AI in optimizing CRC screening in clinical practice.
- 16 June 2024
- Published by Baishideng Publishing Group Inc. in World Journal of Gastrointestinal Endoscopy
- Vol. 16 (6) , 335-342
Open AccessLong-term impact of artificial intelligence on colorectal adenoma detection in high-risk colonoscopy
BACKGROUND Improved adenoma detection rate (ADR) has been demonstrated with artificial intelligence (AI)-assisted colonoscopy. However, data on the real-world application of AI and its effect on colorectal cancer (CRC) screening outcomes is limited. AIM To analyze the long-term impact of AI on a diverse at-risk patient population undergoing diagnostic colonoscopy for positive CRC screening tests or symptoms. METHODS AI software (GI Genius, Medtronic) was implemented into the standard procedure protocol in November 2022. Data was collected on patient demographics, procedure indication, polyp size, location, and pathology. CRC screening outcomes were evaluated before and at different intervals after AI introduction with one year of follow-up. RESULTS We evaluated 1008 colonoscopies (278 pre-AI, 255 early post-AI, 285 established post-AI, and 190 late post-AI). The ADR was 38.1% pre-AI, 42.0% early post-AI (P = 0.77), 40.0% established post-AI (P = 0.44), and 39.5% late post-AI (P = 0.77). There were no significant differences in polyp detection rate (PDR, baseline 59.7%), advanced ADR (baseline 16.2%), and non-neoplastic PDR (baseline 30.0%) before and after AI introduction. CONCLUSION In patients with an increased pre-test probability of having an abnormal colonoscopy, the current generation of AI did not yield enhanced CRC screening metrics over high-quality colonoscopy. Although the potential of AI in colonoscopy is undisputed, current AI technology may not universally elevate screening metrics across all situations and patient populations. Future studies that analyze different AI systems across various patient populations are needed to determine the most effective role of AI in optimizing CRC screening in clinical practice.
- 29 August 2023
- Published by Wolters Kluwer Health in Liver Transplantation
- Vol. 30 (2) , 223-225
Semaglutide is effective in achieving weight loss in liver transplant recipients
An abstract is unavailable. This article is available as a PDF only.
- 29 August 2023
- Published by Wolters Kluwer Health in Liver Transplantation
- Vol. 30 (2) , 223-225
Semaglutide is effective in achieving weight loss in liver transplant recipients
An abstract is unavailable. This article is available as a PDF only.
- 22 June 2023
- Published by Wolters Kluwer Health in Clinical Liver Disease
- Vol. Publish Ah (3) , 113-115
Epidemiology and outcomes of non-alcoholic fatty liver disease in African Americans
Export
- 22 June 2023
- Published by Wolters Kluwer Health in Clinical Liver Disease
- Vol. Publish Ah (3) , 113-115
Epidemiology and outcomes of non-alcoholic fatty liver disease in African Americans
Export
- Open Access
- 1 June 2023
- Published by Wolters Kluwer Health in ACG Case Reports Journal
- Vol. 10 (6) , e01070
Diffuse-Type Pancreatic Ductal Adenocarcinoma Mimicking Autoimmune Pancreatitis
Pancreatic ductal adenocarcinoma (PDAC) classically presents as a solitary mass on cross-sectional imaging. Diffuse-type PDAC is an unusual variant that accounts for 1%–5% of PDACs. Owing to its rarity, there are no established radiographic or endosonographic definitions. We report a unique case of diffuse-type PDAC presenting with imaging findings of 2 distinct masses in the pancreatic head and tail and with endoscopic ultrasound findings of diffuse gland enlargement mimicking autoimmune pancreatitis. The case illustrates the importance of sampling several areas of the pancreas when diffuse enlargement is present on endoscopic ultrasound and multiple masses are seen on cross-sectional imaging.
- 1 June 2023
- Published by Wolters Kluwer Health in ACG Case Reports Journal
- Vol. 10 (6) , e01070
Open AccessDiffuse-Type Pancreatic Ductal Adenocarcinoma Mimicking Autoimmune Pancreatitis
Pancreatic ductal adenocarcinoma (PDAC) classically presents as a solitary mass on cross-sectional imaging. Diffuse-type PDAC is an unusual variant that accounts for 1%–5% of PDACs. Owing to its rarity, there are no established radiographic or endosonographic definitions. We report a unique case of diffuse-type PDAC presenting with imaging findings of 2 distinct masses in the pancreatic head and tail and with endoscopic ultrasound findings of diffuse gland enlargement mimicking autoimmune pancreatitis. The case illustrates the importance of sampling several areas of the pancreas when diffuse enlargement is present on endoscopic ultrasound and multiple masses are seen on cross-sectional imaging.
- Open Access
- 21 October 2020
- Published by Wiley in Journal of Parenteral and Enteral Nutrition
- Vol. 45 (1) , 208-211
Use of Continuous Glucose Monitoring to Assess Parenteral Nutrition–Induced Hyperglycemia in an Adult Patient With Severe COVID‐19
Many patients admitted to the intensive care unit (ICU) are acutely malnourished and often require aggressive and early nutrition support with parenteral nutrition (PN). However, PN‐induced hyperglycemia is a predictor of hospital mortality and is associated with increased length of stay. Elevated blood glucose in hospitalized patients with coronavirus disease 2019 (COVID‐19) is also associated with increased mortality. Real‐time continuous glucose monitoring (rtCGM) is primarily used in the outpatient setting, but there is rapidly growing interest in its applicability to help treat dysglycemia in critically ill patients, especially during the ongoing COVID‐19 pandemic. We assessed the use of rtCGM data (Dexcom G6) in a 58‐year‐old male admitted to the ICU for severe COVID‐19 infection, who developed PN‐induced hyperglycemia with markedly elevated total daily insulin requirements as high as 128 units. rtCGM was used to safely titrate insulin infusion and monitor glucose levels. No episodes of hypoglycemia were observed, despite an extremely aggressive insulin regimen. This case demonstrates the potential utility of rtCGM in the critical care setting and highlights its potential to help conserve personal protective equipment and minimize unnecessary staff exposure in the setting of COVID‐19.
- 21 October 2020
- Published by Wiley in Journal of Parenteral and Enteral Nutrition
- Vol. 45 (1) , 208-211
Open AccessUse of Continuous Glucose Monitoring to Assess Parenteral Nutrition–Induced Hyperglycemia in an Adult Patient With Severe COVID‐19
Many patients admitted to the intensive care unit (ICU) are acutely malnourished and often require aggressive and early nutrition support with parenteral nutrition (PN). However, PN‐induced hyperglycemia is a predictor of hospital mortality and is associated with increased length of stay. Elevated blood glucose in hospitalized patients with coronavirus disease 2019 (COVID‐19) is also associated with increased mortality. Real‐time continuous glucose monitoring (rtCGM) is primarily used in the outpatient setting, but there is rapidly growing interest in its applicability to help treat dysglycemia in critically ill patients, especially during the ongoing COVID‐19 pandemic. We assessed the use of rtCGM data (Dexcom G6) in a 58‐year‐old male admitted to the ICU for severe COVID‐19 infection, who developed PN‐induced hyperglycemia with markedly elevated total daily insulin requirements as high as 128 units. rtCGM was used to safely titrate insulin infusion and monitor glucose levels. No episodes of hypoglycemia were observed, despite an extremely aggressive insulin regimen. This case demonstrates the potential utility of rtCGM in the critical care setting and highlights its potential to help conserve personal protective equipment and minimize unnecessary staff exposure in the setting of COVID‐19.