Kyoung Yoon Shin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Kyoung Yoon Shin has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Dong Hui Lim
Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Republic of Korea
1 shared publication - Jaehyeong Chun
Department of Industrial and System Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
1 shared publication - Kyung-Ah Park
Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
1 shared publication - Sei Yeul Oh
Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
1 shared publication - Sun Hyup Han
Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
1 shared publication - Tae-Young Chung
Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea
1 shared publication
Latest Publications
- Open Access
- 5 May 2020
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 8 (5) , e16225
Deep Learning–Based Prediction of Refractive Error Using Photorefraction Images Captured by a Smartphone: Model Development and Validation Study
Background: Accurately predicting refractive error in children is crucial for detecting amblyopia, which can lead to permanent visual impairment, but is potentially curable if detected early. Various tools have been adopted to more easily screen a large number of patients for amblyopia risk. Objective: For efficient screening, easy access to screening tools and an accurate prediction algorithm are the most important factors. In this study, we developed an automated deep learning–based system to predict the range of refractive error in children (mean age 4.32 years, SD 1.87 years) using 305 eccentric photorefraction images captured with a smartphone. Methods: Photorefraction images were divided into seven classes according to their spherical values as measured by cycloplegic refraction. Results: The trained deep learning model had an overall accuracy of 81.6%, with the following accuracies for each refractive error class: 80.0% for ≤−5.0 diopters (D), 77.8% for >−5.0 D and ≤−3.0 D, 82.0% for >−3.0 D and ≤−0.5 D, 83.3% for >−0.5 D and <+0.5 D, 82.8% for ≥+0.5 D and <+3.0 D, 79.3% for ≥+3.0 D and <+5.0 D, and 75.0% for ≥+5.0 D. These results indicate that our deep learning–based system performed sufficiently accurately. Conclusions: This study demonstrated the potential of precise smartphone-based prediction systems for refractive error using deep learning and further yielded a robust collection of pediatric photorefraction images.
- 5 May 2020
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 8 (5) , e16225
Open AccessDeep Learning–Based Prediction of Refractive Error Using Photorefraction Images Captured by a Smartphone: Model Development and Validation Study
Background: Accurately predicting refractive error in children is crucial for detecting amblyopia, which can lead to permanent visual impairment, but is potentially curable if detected early. Various tools have been adopted to more easily screen a large number of patients for amblyopia risk. Objective: For efficient screening, easy access to screening tools and an accurate prediction algorithm are the most important factors. In this study, we developed an automated deep learning–based system to predict the range of refractive error in children (mean age 4.32 years, SD 1.87 years) using 305 eccentric photorefraction images captured with a smartphone. Methods: Photorefraction images were divided into seven classes according to their spherical values as measured by cycloplegic refraction. Results: The trained deep learning model had an overall accuracy of 81.6%, with the following accuracies for each refractive error class: 80.0% for ≤−5.0 diopters (D), 77.8% for >−5.0 D and ≤−3.0 D, 82.0% for >−3.0 D and ≤−0.5 D, 83.3% for >−0.5 D and <+0.5 D, 82.8% for ≥+0.5 D and <+3.0 D, 79.3% for ≥+3.0 D and <+5.0 D, and 75.0% for ≥+5.0 D. These results indicate that our deep learning–based system performed sufficiently accurately. Conclusions: This study demonstrated the potential of precise smartphone-based prediction systems for refractive error using deep learning and further yielded a robust collection of pediatric photorefraction images.