SISima Baheri Islami

Sima Baheri Islami

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sima Baheri Islami has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Virtual Reality Visualization of CFD Simulated Blood Flow in Cerebral Aneurysms Treated with Flow Diverter Stents

    by Sima Baheri Islami, Mike Wesolowski, William Revell, Xiongbiao Chen

    Virtual reality (VR) has the potential to be a powerful tool for the visualization of simulated blood flow in cerebral aneurysms. This paper presents our study aimed at developing the VR visualization of computational fluid dynamics (CFD) simulations of cerebral aneurysms treated with flow-diverting (FD) stents. First, a spherical sidewall aneurysm located at a simplified internal carotid artery was considered for investigating the impact of stent deployment and positioning on the corresponding spatially time-varying blood flow behavior. The three-dimensional unsteady blood flow over a cardiac cycle was simulated numerically using the finite volume method, and the distributions of hemodynamic parameters inside the aneurysm sac, and on its wall, were presented with and without stent cases. Two stent positions, with and without a gap between the artery wall and stent, were considered to show the influence of correct stent position on aneurysm treatment. Second, a straightforward workflow was developed to import, process, and visualize the CFD analysis data in a VR environment by using open-source software with a high resolution. The Unity3D engine was used for displaying the processed animations in a VR environment operated on a head-mounted display (HMD). The refining process of each frame of time-varying CFD data was automated. The animated flow elements rendered in the VR environment were velocity vectors, velocity contours, streamlines, particle traces, and point clouds. CFD results showed that proper stenting facilitates thrombosis and occlusion of the aneurysm by modification of the flow patterns, which leads to lower inflow jet velocities into the aneurysm, longer turnover time, lower aneurysm-averaged kinetic energy, and lower wall shear stress. Additionally, the results indicated that a gap between the stent and the parent artery may lead to undesirable hemodynamic alterations. The VR visualization illustrated that the recognition of the potential in danger regions of aneurysms and the evaluation of the performance of FD stents in aneurysm treatment can be conducted without the need for several slices through the parent artery and aneurysm, as is required for traditional postprocessing methods. Through VR visualization, the details of the simulation results become readily available by navigating in the 3D animated flow elements using a high-degree-of-freedom headset.


  • A numerical study on tumor-on-chip performance and its optimization for nanodrug-based combination therapy

    by Mohammad Amin Hajari, Sima Baheri Islami, Xiongbiao Chen

    Microfluidic devices, such as the tumor-on-a-chip (ToC), allow for the delivery of multiple drugs as desired for various therapies such as cancer treatment. Due to the complexity involved, visualizing, and gaining knowledge of the performance of such devices through experimentation alone is difficult if not impossible. In this paper, we performed a numerical simulation study on ToC performance, which focuses on the ability to combine multiple nanodrugs and optimized ToC performance. The numerical simulations of the chip performance were performed based on the typical chip design and operating parameters, as well as the established governing equations, boundary conditions, and fluid–structure interaction. The effect of cell injection time and position, inlet flow rate, number of inlets, medium viscosity, and cell concentration on the chip performance in terms of shear stress and cell distribution were examined. The results illustrate the profound effect of operation parameters, thus allowing for rigorously determining operational parameters to prevent spheroids ejection from microwells and to restrict the shear stresses within a physiological range. Also, the results show that triple-inlets can increase the uniformity of cell distribution in comparison with single or double inlets. Based on the simulation results, the architecture of the primary ToC was further optimized, resulting in a novel design that enables applying multiple, yet simultaneous, nanodrugs with optimal drug combination as desired for an individual patient. Furthermore, our simulations on the optimized chip showed a uniform cell distribution required for uniform-sized tumor spheroids generation, and complete medium exchange. Taken together, this study not only illustrates that numerical simulations are effective to visualize the ToCs performance, but also develops a novel ToC design optimized for nanodrug-based combination therapy.