Corrado Vassanelli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Corrado Vassanelli has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Alberto Marini
University of Verona School of Medicine, University Hospital
1 shared publicationFederico Beltrame
University of Verona School of Medicine, University Hospital
1 shared publicationGaudenzio Sacchetti
Ufficio Tecnico, Azienda Ospedaliera Maggiore della Carita', Novara, Italy
1 shared publicationGiampaolo Trevi
Divisione Clinicizzata di Cardiologia, Universita ‘degli Studi di Torino, 2a Facolta’ di Medicina e Chirurgia, Sede di Novara
1 shared publicationGiuliana Menegatti
University of Verona School of Medicine, University Hospital
1 shared publicationJonata Molinari
University of Verona School of Medicine, University Hospital
1 shared publication
Latest Publications
- 1 July 1999
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 22 (7) , 983-989
Implantable Cardioverter Defibrillators and Cellular Telephones: Is There Any Interference?
The aim of our study was to consider cellular telephone interference using different cellular telephones and implantable cardioverter defibrillator (ICD) models. Thirty (26 men, 4 women) patients with ICDs were considered during follow‐up. The ICD models were: Telectronics (7), CPI (7), Medtronic (7), Ventritex (5), and Ela Medical (4). All patients were monitored with surface ECG; permanent telemetric endo‐ECG monitoring was activated. Then, the effect of two different European telephone systems were tested: TACS system (Sony CM‐R111, 2 W power) and GSM system (Motorola MG1–4A11, 2 W power). For both systems, the effect during call, reception, active conversation (dialogue), and passive conversation (listening) were observed. Cellular telephones were located first in contact with the programming head, then near the leads system, and lastly, in the hands of the patient. At the end of the evaluations, memories were interrogated again to check for false arrhythmia detections. In five of these patients during arrhythmia induction at device implant (first implant or ICD replacement), we also evaluated possible interference between cellular telephones in the reception phase and the ventricular fibrillation detection phase of the ICD. All evaluated models showed significant noise in the telemetric transmission when the cellular telephone (both TACS and GSM) was located near the ICD and the programming head; noise was particularly significant during call and reception, in most cases leading to loss of telemetry. No false arrhythmia detections have been observed during tests with cellular telephones located on the ICDs. During tests performed with cellular telephones located near the leads or in the hands of patients, no telemetric noises or false arrhythmia detections were observed. During induced ventricular fibrillation and cellular telephones in reception mode near the device, the arrhythmia recognition was always correct and not delayed. In conclusion, present ICD models seem to be well protected from electromagnetic interference caused by European cellular telephones (TACS and GSM), without under‐/oversensing of ventricular arrhythmias. However, cellular telephones disturb telemetry when located near the programming head. ICD patients should not be advised against the use of cellular telephones, but it has to be avoided during ICD interrogation and programming.
- 1 July 1999
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 22 (7) , 983-989
Implantable Cardioverter Defibrillators and Cellular Telephones: Is There Any Interference?
The aim of our study was to consider cellular telephone interference using different cellular telephones and implantable cardioverter defibrillator (ICD) models. Thirty (26 men, 4 women) patients with ICDs were considered during follow‐up. The ICD models were: Telectronics (7), CPI (7), Medtronic (7), Ventritex (5), and Ela Medical (4). All patients were monitored with surface ECG; permanent telemetric endo‐ECG monitoring was activated. Then, the effect of two different European telephone systems were tested: TACS system (Sony CM‐R111, 2 W power) and GSM system (Motorola MG1–4A11, 2 W power). For both systems, the effect during call, reception, active conversation (dialogue), and passive conversation (listening) were observed. Cellular telephones were located first in contact with the programming head, then near the leads system, and lastly, in the hands of the patient. At the end of the evaluations, memories were interrogated again to check for false arrhythmia detections. In five of these patients during arrhythmia induction at device implant (first implant or ICD replacement), we also evaluated possible interference between cellular telephones in the reception phase and the ventricular fibrillation detection phase of the ICD. All evaluated models showed significant noise in the telemetric transmission when the cellular telephone (both TACS and GSM) was located near the ICD and the programming head; noise was particularly significant during call and reception, in most cases leading to loss of telemetry. No false arrhythmia detections have been observed during tests with cellular telephones located on the ICDs. During tests performed with cellular telephones located near the leads or in the hands of patients, no telemetric noises or false arrhythmia detections were observed. During induced ventricular fibrillation and cellular telephones in reception mode near the device, the arrhythmia recognition was always correct and not delayed. In conclusion, present ICD models seem to be well protected from electromagnetic interference caused by European cellular telephones (TACS and GSM), without under‐/oversensing of ventricular arrhythmias. However, cellular telephones disturb telemetry when located near the programming head. ICD patients should not be advised against the use of cellular telephones, but it has to be avoided during ICD interrogation and programming.
- 1 January 1999
- Published by Springer Nature in Drugs
- Vol. 57 (Supplement) , 19-26
Coronary Artery Vasomotion and Post-Stenotic Coronary Artery Blood Flow after Intracoronary Lacidipine in Patients with Ischaemic Heart Disease
Background: The calcium antagonist lacidipine has been shown to be highly vasoselective and to improve myocardial perfusion in hypertensive patients. However, its effects on coronary artery vasomotility and on post-stenotic coronary flow reserve in patients with atherosclerotic heart disease are unknown. Objectives: This study was designed to investigate the acute direct effects of repeated infusions of lacidipine on epicardial coronary artery vasomotion and on post-stenotic coronary artery blood flow in patients with stable angina pectoris and angiographic evidence of coronary heart disease. Methods: In 8 patients with stable angina and moderate to severe stenosis of the left coronary artery, measurements of epicardial dimensions (quantitative angiography) and of coronary blood flow (Doppler guidewire) distal to a stenosis were performed at baseline and after 3 repeated intracoronary boluses of 12μg of lacidipine. Results were compared with those obtained after 10mg of intracoronary papaverine. Results: The intracoronary administration of lacidipine was well tolerated, without any adverse effects. Lacidipine significantly increased the minimal luminal diameter of the lesion (peak relative increase of 43.7%), without significant changes in heart rate and systolic aortic pressure. Intracoronary lacidipine caused a dose-dependent increase in coronary flow reserve. Maximal vasodilatory effects were equivalent to those obtained with intracoronary papaverine. Conclusions: These results suggest that lacidipine acts directly as a potent vasodilator in stenotic epicardial vessels and improves myocardial perfusion distal to a moderately severe stenosis in patients with stable angina.
- 1 January 1999
- Published by Springer Nature in Drugs
- Vol. 57 (Supplement) , 19-26
Coronary Artery Vasomotion and Post-Stenotic Coronary Artery Blood Flow after Intracoronary Lacidipine in Patients with Ischaemic Heart Disease
Background: The calcium antagonist lacidipine has been shown to be highly vasoselective and to improve myocardial perfusion in hypertensive patients. However, its effects on coronary artery vasomotility and on post-stenotic coronary flow reserve in patients with atherosclerotic heart disease are unknown. Objectives: This study was designed to investigate the acute direct effects of repeated infusions of lacidipine on epicardial coronary artery vasomotion and on post-stenotic coronary artery blood flow in patients with stable angina pectoris and angiographic evidence of coronary heart disease. Methods: In 8 patients with stable angina and moderate to severe stenosis of the left coronary artery, measurements of epicardial dimensions (quantitative angiography) and of coronary blood flow (Doppler guidewire) distal to a stenosis were performed at baseline and after 3 repeated intracoronary boluses of 12μg of lacidipine. Results were compared with those obtained after 10mg of intracoronary papaverine. Results: The intracoronary administration of lacidipine was well tolerated, without any adverse effects. Lacidipine significantly increased the minimal luminal diameter of the lesion (peak relative increase of 43.7%), without significant changes in heart rate and systolic aortic pressure. Intracoronary lacidipine caused a dose-dependent increase in coronary flow reserve. Maximal vasodilatory effects were equivalent to those obtained with intracoronary papaverine. Conclusions: These results suggest that lacidipine acts directly as a potent vasodilator in stenotic epicardial vessels and improves myocardial perfusion distal to a moderately severe stenosis in patients with stable angina.