Saman Azhari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Saman Azhari has a total of 152 co-authors. Here are the top co-authors by number of shared publications:
- Hirofumi Tanaka
Department of Human Intelligence Systems Graduate School of Life Science and Systems Engineering Kyushu Institute of Technology Kitakyushu Japan
15 shared publications - Intan Helina Hasan
Universiti Putra Malaysia
12 shared publications - Yuki Usami
Department of Human Intelligence Systems Graduate School of Life Science and Systems Engineering Kyushu Institute of Technology Kitakyushu Japan
12 shared publications - Ismayadi Ismail
Universiti Putra Malaysia
11 shared publications - Mohd Nizar Hamidon
Universiti Putra Malaysia
9 shared publications - Takeo Miyake
Waseda University
9 shared publications
Latest Publications
- 13 November 2026
- Published by Wiley in Advanced Materials Technologies
Stretchable Wrinkled‐Gold Antenna for High‐Sensitivity Intraocular Pressure Monitoring Smart Contact Lens
Glaucoma is the main cause of irreversible blindness worldwide, and it is closely related to intraocular pressure (IOP). However, single or short‐term IOP measurements cannot fully reflect the biomechanical environment in the eye and the risk of disease progression. Therefore, continuous daily IOP monitoring is very important for the early diagnosis and long‐term treatment of glaucoma. To solve this problem, this study proposes a smart contact lens sensor that combines the Inductor‐Capacitor resonant circuit principle with a sandwich‐structured, wrinkled gold antenna for wireless IOP monitoring. By structurally modifying conventional materials, the device can flexibly adapt to eyeball deformation while maintaining excellent electrical stability. The results show that the sensor's sensitivity is 0.54 MHz·mmHg −1 in the balloon model and 0.25 MHz·mmHg −1 in the ex vivo porcine eye, with a good linear relationship between IOP changes and resonance frequency shifts. IOP was also successfully monitored in vivo using a live rabbit. Cytotoxicity experiments show that cell survival exceeds 99%, indicating good biocompatibility of the device at the cellular level. This study provides a new technical direction for integrating contact lens sensors with wearable devices, such as smart glasses, to enable continuous, non‐invasive IOP monitoring in daily life.
- 13 November 2026
- Published by Wiley in Advanced Materials Technologies
Stretchable Wrinkled‐Gold Antenna for High‐Sensitivity Intraocular Pressure Monitoring Smart Contact Lens
Glaucoma is the main cause of irreversible blindness worldwide, and it is closely related to intraocular pressure (IOP). However, single or short‐term IOP measurements cannot fully reflect the biomechanical environment in the eye and the risk of disease progression. Therefore, continuous daily IOP monitoring is very important for the early diagnosis and long‐term treatment of glaucoma. To solve this problem, this study proposes a smart contact lens sensor that combines the Inductor‐Capacitor resonant circuit principle with a sandwich‐structured, wrinkled gold antenna for wireless IOP monitoring. By structurally modifying conventional materials, the device can flexibly adapt to eyeball deformation while maintaining excellent electrical stability. The results show that the sensor's sensitivity is 0.54 MHz·mmHg −1 in the balloon model and 0.25 MHz·mmHg −1 in the ex vivo porcine eye, with a good linear relationship between IOP changes and resonance frequency shifts. IOP was also successfully monitored in vivo using a live rabbit. Cytotoxicity experiments show that cell survival exceeds 99%, indicating good biocompatibility of the device at the cellular level. This study provides a new technical direction for integrating contact lens sensors with wearable devices, such as smart glasses, to enable continuous, non‐invasive IOP monitoring in daily life.
- Open Access
- 21 August 2026
- Published by Wiley in Advanced Functional Materials
- Vol. 36 (76) , e77779
Dual‐Layer Conducting and Redox Polymer Bioanodes for Synergistic Enhancement of Microbial Extracellular Electron Transfer
Microbial electrochemical systems (MESs) offer a sustainable platform for energy conversion and biosensing, but their performance is limited by total low extracellular electron transfer (EET) and insufficient electrode interface engineering. Existing studies tend to improve ether the electrochemically active surface area (EASA) of bioelectrodes by conducting coatings or the bio‐electrochemical interfacial electron transfer by redox mediation, but rarely both. To address this limitation, a functionally integrated bioanode was developed by combing a conductive poly(3,4‐ethylenedioxythiophene) (PEDOT) layer with a ferrocene‐modified linear polyethyleneimine (Fc‐LPEI) redox polymer (RP) on carbon felt. This dual‐layer architecture integrates high conductivity and large EASA with efficient redox mediation. Utilizing Shewanella oneidensis MR‐1, the resulting CF‐PEDOT‐RP electrode achieved a maximum current of 1.8 ± 0.1 mA (720 ± 20 µA cm − 2 ), outperforming electrodes modified with PEDOT alone (224 µA cm − 2 ) or Fc‐LPEI alone (480 µA cm − 2 ), demonstrating clear synergistic enhancement. Electrochemical analysis revealed that PEDOT improves conductivity and promotes bacterial attachment, while Fc‐LPEI facilitates reversible electron transfer at the biointerface. The composite electrode also exhibited improved stability and enabled both bioenergy generation and sensitive biosensing. These results establish a versatile strategy for engineering high‐performance bioelectrodes through functional integration of conductive and redox‐active polymers.
- 21 August 2026
- Published by Wiley in Advanced Functional Materials
- Vol. 36 (76) , e77779
Open AccessDual‐Layer Conducting and Redox Polymer Bioanodes for Synergistic Enhancement of Microbial Extracellular Electron Transfer
Microbial electrochemical systems (MESs) offer a sustainable platform for energy conversion and biosensing, but their performance is limited by total low extracellular electron transfer (EET) and insufficient electrode interface engineering. Existing studies tend to improve ether the electrochemically active surface area (EASA) of bioelectrodes by conducting coatings or the bio‐electrochemical interfacial electron transfer by redox mediation, but rarely both. To address this limitation, a functionally integrated bioanode was developed by combing a conductive poly(3,4‐ethylenedioxythiophene) (PEDOT) layer with a ferrocene‐modified linear polyethyleneimine (Fc‐LPEI) redox polymer (RP) on carbon felt. This dual‐layer architecture integrates high conductivity and large EASA with efficient redox mediation. Utilizing Shewanella oneidensis MR‐1, the resulting CF‐PEDOT‐RP electrode achieved a maximum current of 1.8 ± 0.1 mA (720 ± 20 µA cm − 2 ), outperforming electrodes modified with PEDOT alone (224 µA cm − 2 ) or Fc‐LPEI alone (480 µA cm − 2 ), demonstrating clear synergistic enhancement. Electrochemical analysis revealed that PEDOT improves conductivity and promotes bacterial attachment, while Fc‐LPEI facilitates reversible electron transfer at the biointerface. The composite electrode also exhibited improved stability and enabled both bioenergy generation and sensitive biosensing. These results establish a versatile strategy for engineering high‐performance bioelectrodes through functional integration of conductive and redox‐active polymers.
- 10 April 2026
- Published by American Chemical Society (ACS) in ACS Sensors
Enhanced Sensitivity of Real-Time Intraocular Pressure Monitoring by Integration of a Wrinkled Gold-Based Capacitive Sensor with Parity-Time Symmetry Wireless Technology
Glaucoma is an ophthalmic condition characterized by elevated intraocular pressure (IOP) due to the obstruction of aqueous humor flow in the anterior chamber of the eye. This condition can damage the optic nerve, ultimately leading to blindness. Therefore, real-time monitoring of IOP is essential for preventing glaucoma and other ophthalmic diseases. A smart soft contact lens with a capacitive sensor was developed to monitor IOP. The sensor employs a wrinkled gold-film electrode that can stretch by up to 50% of its initial length without a significant change in resistance. A soft dielectric layer composed of Ecoflex supports deformability, stability, and sensitivity. Compared to a flat gold film, the wrinkled type doubles the capacitance response, increasing sensitivity from 393 to 1057 ppm/mmHg. By incorporating a parallel parity-time (PT) symmetry setup for wireless detection and leveraging its near exceptional points characteristics, enhanced coupling and frequency change tracking caused by corneal deformation are achieved, boosting the sensitivity approximately 7.5 times that of the conventional system. The maximum negative impedance of -5000 Ω in the PT symmetry setup is 5 times that of the conventional and 2500 times that of the commercial inductive antenna, enabling clearer IOP detection and superior pressure sensing performance. Lastly, the human corneal epithelial (HCE) cell culture experiments indicate preliminary in vitro biocompatibility.
- 10 April 2026
- Published by American Chemical Society (ACS) in ACS Sensors
Enhanced Sensitivity of Real-Time Intraocular Pressure Monitoring by Integration of a Wrinkled Gold-Based Capacitive Sensor with Parity-Time Symmetry Wireless Technology
Glaucoma is an ophthalmic condition characterized by elevated intraocular pressure (IOP) due to the obstruction of aqueous humor flow in the anterior chamber of the eye. This condition can damage the optic nerve, ultimately leading to blindness. Therefore, real-time monitoring of IOP is essential for preventing glaucoma and other ophthalmic diseases. A smart soft contact lens with a capacitive sensor was developed to monitor IOP. The sensor employs a wrinkled gold-film electrode that can stretch by up to 50% of its initial length without a significant change in resistance. A soft dielectric layer composed of Ecoflex supports deformability, stability, and sensitivity. Compared to a flat gold film, the wrinkled type doubles the capacitance response, increasing sensitivity from 393 to 1057 ppm/mmHg. By incorporating a parallel parity-time (PT) symmetry setup for wireless detection and leveraging its near exceptional points characteristics, enhanced coupling and frequency change tracking caused by corneal deformation are achieved, boosting the sensitivity approximately 7.5 times that of the conventional system. The maximum negative impedance of -5000 Ω in the PT symmetry setup is 5 times that of the conventional and 2500 times that of the commercial inductive antenna, enabling clearer IOP detection and superior pressure sensing performance. Lastly, the human corneal epithelial (HCE) cell culture experiments indicate preliminary in vitro biocompatibility.
- 2 April 2026
- Published by American Chemical Society (ACS) in ACS Applied Electronic Materials
- Vol. 8 (7) , 3045-3057
Passive Inductive Eye-Tracking via a Resonant Contact Lens
- 2 April 2026
- Published by American Chemical Society (ACS) in ACS Applied Electronic Materials
- Vol. 8 (7) , 3045-3057
Passive Inductive Eye-Tracking via a Resonant Contact Lens
- Open Access
- 10 January 2026
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 18 (10) , 5190-5204
MoSe 2 /SWNT core–shell hybrids with space-charge-limited conduction and nonlinear dynamics for in-materio physical reservoir computing
MoSe 2 /SWNT core–shell hybrids enable space-charge-limited conduction-based physical reservoir computing, achieving 90% NARMA2 accuracy and robust harmonic-rich waveform reconstruction.
- 10 January 2026
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 18 (10) , 5190-5204
Open AccessMoSe 2 /SWNT core–shell hybrids with space-charge-limited conduction and nonlinear dynamics for in-materio physical reservoir computing
MoSe 2 /SWNT core–shell hybrids enable space-charge-limited conduction-based physical reservoir computing, achieving 90% NARMA2 accuracy and robust harmonic-rich waveform reconstruction.
- Open Access
- 6 July 2025
- Published by Wiley in Advanced Materials Technologies
Self‐Sterilizing Face Mask Employing Enzymatic Power Generation
The coronavirus disease 2019 (COVID‐19) pandemic has raised awareness regarding the proper wearing and functionality of face masks to prevent viral and bacterial infections through the nasal and oral pathways. However, large‐scale daily use of disposable face masks introduces large volumes of waste. Reusable face masks will significantly reduce waste, but the lack of rapid sterilization prevents their use. To realize on‐the‐go sterilization, wearable biofuel cells are integrated into reusable conductive cloth face masks that generate electric current. To ensure softness and functionality, the face mask is modified with poly(3,4‐ethylenedioxythiophene) polystyrene sulfonate, a well‐known biocompatible conducting polymer. Meanwhile, fiber‐based bioanode and biocathode utilizing alcohol dehydrogenase for ethanol oxidation and bilirubin oxidase for oxygen reduction, respectively, are sewn on the conductive face mask. After assembling the “electric face mask”, modulation of current flow through its conductive region is demonstrated. In tests with two bacteria, Shewanella oneidensis MR‐1 and Escherichia coli, a minimum current flow of 20 µA significantly increases the bacteria's death rates. Therefore, this enzymatically powered mask provides necessary electric currents to kill bacteria on a conductive surface. Importantly, bacterial sterilization using the fabricated electric face masks is successfully demonstrated, adding a step to utilizing soft bioelectrical technology toward a more sustainable society.
- 6 July 2025
- Published by Wiley in Advanced Materials Technologies
Open AccessSelf‐Sterilizing Face Mask Employing Enzymatic Power Generation
The coronavirus disease 2019 (COVID‐19) pandemic has raised awareness regarding the proper wearing and functionality of face masks to prevent viral and bacterial infections through the nasal and oral pathways. However, large‐scale daily use of disposable face masks introduces large volumes of waste. Reusable face masks will significantly reduce waste, but the lack of rapid sterilization prevents their use. To realize on‐the‐go sterilization, wearable biofuel cells are integrated into reusable conductive cloth face masks that generate electric current. To ensure softness and functionality, the face mask is modified with poly(3,4‐ethylenedioxythiophene) polystyrene sulfonate, a well‐known biocompatible conducting polymer. Meanwhile, fiber‐based bioanode and biocathode utilizing alcohol dehydrogenase for ethanol oxidation and bilirubin oxidase for oxygen reduction, respectively, are sewn on the conductive face mask. After assembling the “electric face mask”, modulation of current flow through its conductive region is demonstrated. In tests with two bacteria, Shewanella oneidensis MR‐1 and Escherichia coli, a minimum current flow of 20 µA significantly increases the bacteria's death rates. Therefore, this enzymatically powered mask provides necessary electric currents to kill bacteria on a conductive surface. Importantly, bacterial sterilization using the fabricated electric face masks is successfully demonstrated, adding a step to utilizing soft bioelectrical technology toward a more sustainable society.
- Open Access
- 29 June 2025
- Published by Wiley in Advanced Intelligent Systems
- Vol. 7 (12)
Integration of Cholesterol Oxidase‐Based Biosensors on a Smart Contact Lens for Wireless Cholesterol Monitoring from Tears
Cholesterol plays a critical role in physiological functions, but elevated levels increase the risk of cardiovascular disease. Regular cholesterol monitoring is essential for elderly or obese individuals. Current methods, such as blood tests, are invasive, inconvenient, and require a professional operator. In contrast, tears, as an accessible body fluid, offer a promising alternative for noninvasive monitoring due to their correlation with blood cholesterol levels. Herein, a noninvasive approach for monitoring cholesterol levels in tears using a biosensor integrated into a smart contact lens is reported. The biosensor employs cholesterol oxidases as the biocatalyst, coupled with an osmium‐based mediator, to detect cholesterol concentrations ranging from 0.1 mM to 1.2 mM in artificial tears. A key challenge is the extremely low cholesterol concentration in tears, which is addressed using a parity‐time (P‐T) symmetry‐based magnetic resonance coupling system. This system enables wireless signal reading and achieves high sensitivity due to its high‐quality (Q) factor, which can achieve a detection limit of 0.061 mM. This portable, high‐sensitivity smart contact lens demonstrates significant potential as a wearable device for continuous, noninvasive cholesterol monitoring. The findings contribute to advancing tear‐based diagnostic systems and highlight the scientific importance of utilizing tear biomarkers for health monitoring.
- 29 June 2025
- Published by Wiley in Advanced Intelligent Systems
- Vol. 7 (12)
Open AccessIntegration of Cholesterol Oxidase‐Based Biosensors on a Smart Contact Lens for Wireless Cholesterol Monitoring from Tears
Cholesterol plays a critical role in physiological functions, but elevated levels increase the risk of cardiovascular disease. Regular cholesterol monitoring is essential for elderly or obese individuals. Current methods, such as blood tests, are invasive, inconvenient, and require a professional operator. In contrast, tears, as an accessible body fluid, offer a promising alternative for noninvasive monitoring due to their correlation with blood cholesterol levels. Herein, a noninvasive approach for monitoring cholesterol levels in tears using a biosensor integrated into a smart contact lens is reported. The biosensor employs cholesterol oxidases as the biocatalyst, coupled with an osmium‐based mediator, to detect cholesterol concentrations ranging from 0.1 mM to 1.2 mM in artificial tears. A key challenge is the extremely low cholesterol concentration in tears, which is addressed using a parity‐time (P‐T) symmetry‐based magnetic resonance coupling system. This system enables wireless signal reading and achieves high sensitivity due to its high‐quality (Q) factor, which can achieve a detection limit of 0.061 mM. This portable, high‐sensitivity smart contact lens demonstrates significant potential as a wearable device for continuous, noninvasive cholesterol monitoring. The findings contribute to advancing tear‐based diagnostic systems and highlight the scientific importance of utilizing tear biomarkers for health monitoring.
- Open Access
- 8 June 2025
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 287, 117674
A plant-insertable multi-enzyme biosensor for the real-time monitoring of stomatal sucrose uptake
- 8 June 2025
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 287, 117674
Open AccessA plant-insertable multi-enzyme biosensor for the real-time monitoring of stomatal sucrose uptake
- Open Access
- 3 June 2025
- Published by Wiley in Small Science
- Vol. 5 (7)
MXene‐Integrated Contact Lens: A Breakthrough in Wearable Eye Protection and Healthcare
Smart contact lenses with electronic circuits are rapidly advancing for health monitoring and sensing applications, but concerns over electromagnetic (EM) radiation exposure remain. As these devices are near commercialization, protecting the eyes from such radiation is crucial. MXenes (Mn+1XnTx, where M is a transition metal, X is carbon and/or nitrogen, and Tx denotes the functional groups [e.g., OH, F, O, etc.]), a class of 2D transition metal carbides/nitrides, offer exceptional properties such as high conductivity, biocompatibility, and strong EM shielding, making them ideal for preventing radiation‐induced eye diseases like cataracts. Herein, an MXene‐coated contact lens platform that effectively reduces EM radiation exposure while maintaining over 80% visible light transmission, 90% cell viability, and robust shielding capabilities is presented. This approach achieves stable integration of MXene nanosheets on soft contact lenses and mitigates their oxidation degradation. The lens also enhances dehydration protection and demonstrates safety by showing no signs of inflammation or adverse effects in rabbit eyes. These findings highlight MXene‐coated contact lenses as a promising solution for next‐generation wearable technologies and healthcare applications.
- 3 June 2025
- Published by Wiley in Small Science
- Vol. 5 (7)
Open AccessMXene‐Integrated Contact Lens: A Breakthrough in Wearable Eye Protection and Healthcare
Smart contact lenses with electronic circuits are rapidly advancing for health monitoring and sensing applications, but concerns over electromagnetic (EM) radiation exposure remain. As these devices are near commercialization, protecting the eyes from such radiation is crucial. MXenes (Mn+1XnTx, where M is a transition metal, X is carbon and/or nitrogen, and Tx denotes the functional groups [e.g., OH, F, O, etc.]), a class of 2D transition metal carbides/nitrides, offer exceptional properties such as high conductivity, biocompatibility, and strong EM shielding, making them ideal for preventing radiation‐induced eye diseases like cataracts. Herein, an MXene‐coated contact lens platform that effectively reduces EM radiation exposure while maintaining over 80% visible light transmission, 90% cell viability, and robust shielding capabilities is presented. This approach achieves stable integration of MXene nanosheets on soft contact lenses and mitigates their oxidation degradation. The lens also enhances dehydration protection and demonstrates safety by showing no signs of inflammation or adverse effects in rabbit eyes. These findings highlight MXene‐coated contact lenses as a promising solution for next‐generation wearable technologies and healthcare applications.
- 16 March 2025
- Published by Wiley in Advanced Intelligent Systems
- Vol. 7 (3)
Haptic In‐Sensor Computing Device Based on CNT/PDMS Nanocomposite Physical Reservoir
- 16 March 2025
- Published by Wiley in Advanced Intelligent Systems
- Vol. 7 (3)
Haptic In‐Sensor Computing Device Based on CNT/PDMS Nanocomposite Physical Reservoir