Zhifeng Li
Zhifeng Li has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Sheng Wang
2 shared publicationsBo Rong
1 shared publicationChang-Li Ruan
1 shared publication- Dajun Fan
Institute of Modern Physics
1 shared publication Haoxian Yang
1 shared publicationHong-Bing Song
1 shared publication
Latest Publications
- Open Access
- 11 August 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1)
Assessment of cross-section library impact on neutron beam quality in AB-BNCT monte carlo studies
This study investigated the impact of nuclear reaction cross-sections data from various nuclear data libraries on neutron parameters in Monte Carlo simulations using the PHITS code for accelerator-based BNCT (AB-BNCT). Specifically, it evaluated the effect of different proton data libraries-ENDF/B VII.1, ENDF/B VIII.1, CP2020, and JENDL-5.0-on the neutron yields from the 7Li(p, n)7Be reaction in a natural lithium target. The results showed that the calculated target neutron yields differed by up to 16.86%, with notable variations in the target neutron energy spectra. Furthermore, the study assessed the impact of neutron libraries-ENDF/B VII.1, ENDF/B VIII.0, ENDF/B VIII.1, JEFF-3.3, CENDL-3.2, and JENDL-5.0-on neutron beam parameters at the BSA exit, based on the neutron spectrum at the lithium target. It was found that the epithermal neutron intensity and fast neutron component calculated with the ENDF/B VIII.1 neutron library were 5.51%-8.61% and 19.04%-63.94% higher, respectively, than that obtained with the other neutron libraries, due to a more prominent neutron flux peak. The fast neutron component, calculated using the JENDL-5.0 neutron library, was 23.42%-63.94% lower compared to other libraries, while the gamma-ray component derived from the JEFF-3.3, CENDL-3.2, and JENDL-5.0 neutron libraries was 6.79%-10.08% higher than that from the ENDF/B series. Further analysis revealed that the discrepancies were primarily caused by differences in the neutron cross-section data of F, Pb, Mg, Cu, and H in specific neutron libraries. In particular, the differences in the neutron cross-sections of F and Pb accounted for the variations in the obtained BSA outlet spectra and neutron parameters when using the ENDF/B VIII.1 and JENDL-5.0 neutron libraries. The elevated gamma-ray component observed in the JEFF-3.3 and CENDL-3.2 neutron libraries, compared to the ENDF/B series, was largely due to the different cross-sections of Mg, Cu, and H. These findings underscored the considerable discrepancies arising from variations in nuclear data libraries and emphasized the critical importance of appropriate selection of nuclear data libraries for BNCT applications.
- 11 August 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1)
Open AccessAssessment of cross-section library impact on neutron beam quality in AB-BNCT monte carlo studies
This study investigated the impact of nuclear reaction cross-sections data from various nuclear data libraries on neutron parameters in Monte Carlo simulations using the PHITS code for accelerator-based BNCT (AB-BNCT). Specifically, it evaluated the effect of different proton data libraries-ENDF/B VII.1, ENDF/B VIII.1, CP2020, and JENDL-5.0-on the neutron yields from the 7Li(p, n)7Be reaction in a natural lithium target. The results showed that the calculated target neutron yields differed by up to 16.86%, with notable variations in the target neutron energy spectra. Furthermore, the study assessed the impact of neutron libraries-ENDF/B VII.1, ENDF/B VIII.0, ENDF/B VIII.1, JEFF-3.3, CENDL-3.2, and JENDL-5.0-on neutron beam parameters at the BSA exit, based on the neutron spectrum at the lithium target. It was found that the epithermal neutron intensity and fast neutron component calculated with the ENDF/B VIII.1 neutron library were 5.51%-8.61% and 19.04%-63.94% higher, respectively, than that obtained with the other neutron libraries, due to a more prominent neutron flux peak. The fast neutron component, calculated using the JENDL-5.0 neutron library, was 23.42%-63.94% lower compared to other libraries, while the gamma-ray component derived from the JEFF-3.3, CENDL-3.2, and JENDL-5.0 neutron libraries was 6.79%-10.08% higher than that from the ENDF/B series. Further analysis revealed that the discrepancies were primarily caused by differences in the neutron cross-section data of F, Pb, Mg, Cu, and H in specific neutron libraries. In particular, the differences in the neutron cross-sections of F and Pb accounted for the variations in the obtained BSA outlet spectra and neutron parameters when using the ENDF/B VIII.1 and JENDL-5.0 neutron libraries. The elevated gamma-ray component observed in the JEFF-3.3 and CENDL-3.2 neutron libraries, compared to the ENDF/B series, was largely due to the different cross-sections of Mg, Cu, and H. These findings underscored the considerable discrepancies arising from variations in nuclear data libraries and emphasized the critical importance of appropriate selection of nuclear data libraries for BNCT applications.
- 17 March 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1063
Double-layered beam shaping assembly design based on intelligent optimization method coupling neural network and genetic algorithm for BNCT
- 17 March 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1063
Double-layered beam shaping assembly design based on intelligent optimization method coupling neural network and genetic algorithm for BNCT
- Open Access
- 6 February 2023
- Published by Wiley in International Journal of Energy Research
- Vol. 2023, 1-27
Review of Refractive Index-Matching Techniques of Polymethyl Methacrylate in Flow Field Visualization Experiments
The development of modern computational fluid dynamics (CFD) technology provides many preliminary references for experimental design. In addition, the CFD calculation results verified by experiments can display enormous microdata in areas that are difficult to measure through experiments, as an extension. This can make measurements more reasonable and effective, shorten measurement times, and save manpower and capital significantly. Therefore, it is vital to verify the accuracy of CFD calculation results, especially in cases of complex structures and multiphase flows. The results of model tests can be utilized in a prototype experiment by properly designing a test section and selecting a working fluid if the Reynolds similarity criterion is met. Optical measurement technology is a noninvasive measurement method, and the impact on the flow field can be almost negligible. It is advised to use transparent materials and prepare a refractive index-matching (RIM) fluid to obtain a good optical path. Polymethyl methacrylate (PMMA) is widely used in flow field visualization experiments because of its good light transmission and mechanical strength. This review is aimed at introducing the current status of different flow field measurement techniques; moreover, it is intended to help the readers to become more familiar with the principles of RIM, the characteristics, applications, and usage suggestions of various RIM fluid schemes of PMMA, providing references for researchers in the design, preparation, and conducting stages of flow field visualization measurement experiments. This review is divided into five sections. In the introduction section, Chapter 1, relevant research developments and related results of flow field measurements are presented, followed by the innovations and benefits of this paper. In Chapter 2, the flow field visualization measurements are presented and a derivation is shown. In Chapter 3, some RIM fluid schemes of PMMA and their applications are given, which are very valuable for peers. In Chapter 4, the measurement and analysis of some physical properties are described. In the RIM process, it is necessary to focus on the RI, density, dynamic viscosity, compatibility, stability, safety, and cost of RIM fluids. These factors greatly impact the accuracy of experimental results, experimental progress, and safety of the experimenters. Based on the analysis and our practical experience, some suggestions are given for preparing and using RIM fluids. In the conclusion section, Chapter 5, the results and practical implications of this paper are summarized.
- 6 February 2023
- Published by Wiley in International Journal of Energy Research
- Vol. 2023, 1-27
Open AccessReview of Refractive Index-Matching Techniques of Polymethyl Methacrylate in Flow Field Visualization Experiments
The development of modern computational fluid dynamics (CFD) technology provides many preliminary references for experimental design. In addition, the CFD calculation results verified by experiments can display enormous microdata in areas that are difficult to measure through experiments, as an extension. This can make measurements more reasonable and effective, shorten measurement times, and save manpower and capital significantly. Therefore, it is vital to verify the accuracy of CFD calculation results, especially in cases of complex structures and multiphase flows. The results of model tests can be utilized in a prototype experiment by properly designing a test section and selecting a working fluid if the Reynolds similarity criterion is met. Optical measurement technology is a noninvasive measurement method, and the impact on the flow field can be almost negligible. It is advised to use transparent materials and prepare a refractive index-matching (RIM) fluid to obtain a good optical path. Polymethyl methacrylate (PMMA) is widely used in flow field visualization experiments because of its good light transmission and mechanical strength. This review is aimed at introducing the current status of different flow field measurement techniques; moreover, it is intended to help the readers to become more familiar with the principles of RIM, the characteristics, applications, and usage suggestions of various RIM fluid schemes of PMMA, providing references for researchers in the design, preparation, and conducting stages of flow field visualization measurement experiments. This review is divided into five sections. In the introduction section, Chapter 1, relevant research developments and related results of flow field measurements are presented, followed by the innovations and benefits of this paper. In Chapter 2, the flow field visualization measurements are presented and a derivation is shown. In Chapter 3, some RIM fluid schemes of PMMA and their applications are given, which are very valuable for peers. In Chapter 4, the measurement and analysis of some physical properties are described. In the RIM process, it is necessary to focus on the RI, density, dynamic viscosity, compatibility, stability, safety, and cost of RIM fluids. These factors greatly impact the accuracy of experimental results, experimental progress, and safety of the experimenters. Based on the analysis and our practical experience, some suggestions are given for preparing and using RIM fluids. In the conclusion section, Chapter 5, the results and practical implications of this paper are summarized.
- Open Access
- 12 January 2023
- Published by Frontiers Media SA in Frontiers in Energy Research
- Vol. 10
Application of the improved quasi-static coupled probability theory method to transient safety analysis of an experimental facility
The accelerator-driven sub-critical system is driven by external neutron sources, which are generated by the spallation reaction and maintain the stable operation of the sub-critical core, while the external neutron source increases the complexity of reactor neutron kinetic processes. This article focuses on simulation analysis of neutron space–time kinetics with a dynamic analysis code, which is developed based on the improved quasi-static approximation and Monte Carlo neutron transport method. The amplitude function and shape functions are solved to achieve the dynamics simulation process. Then, the transient responses of beam interruptions and reactivity insertions are calculated and analyzed for an experimental facility. To further verify the correctness and reliability of dynamic behavior, the simulation results are compared with experimental values, and the results show that the normalized neutron fluxes varying with time are in good agreement with the corresponding values. It can be concluded that the improved quasi-static coupled probability theory method can be used to solve the neutron space–time kinetic problem of the experimental facility, and the results are reliable.
- 12 January 2023
- Published by Frontiers Media SA in Frontiers in Energy Research
- Vol. 10
Open AccessApplication of the improved quasi-static coupled probability theory method to transient safety analysis of an experimental facility
The accelerator-driven sub-critical system is driven by external neutron sources, which are generated by the spallation reaction and maintain the stable operation of the sub-critical core, while the external neutron source increases the complexity of reactor neutron kinetic processes. This article focuses on simulation analysis of neutron space–time kinetics with a dynamic analysis code, which is developed based on the improved quasi-static approximation and Monte Carlo neutron transport method. The amplitude function and shape functions are solved to achieve the dynamics simulation process. Then, the transient responses of beam interruptions and reactivity insertions are calculated and analyzed for an experimental facility. To further verify the correctness and reliability of dynamic behavior, the simulation results are compared with experimental values, and the results show that the normalized neutron fluxes varying with time are in good agreement with the corresponding values. It can be concluded that the improved quasi-static coupled probability theory method can be used to solve the neutron space–time kinetic problem of the experimental facility, and the results are reliable.