Jing Jia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jing Jia has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Fei Ding
School of Aerospace Science and Technology, Xidian University 1 , Xi'an 710071, China
2 shared publications Yanming Liu
School of Aerospace Science and Technology, Xidian University 1 , Xi'an 710071, China
2 shared publications- Bin Zhou
CAS CEMCS-CUHK Joint Laboratory, New Cornerstone Science Laboratory, Key Laboratory of Multi-Cell Systems, Shanghai Institute of Biochemistry and Cell Biology, Center for Excellence in Molecular Cell Science, Chinese Academy of Sciences, University of Chinese Academy of Sciences, Shanghai, China
1 shared publication - Jia Zhang
School of Aerospace Science and Technology, Xidian University, Xian, China
1 shared publication - Jiaxin Li
School of Aerospace Science and Technology, Xidian University 1 , Xi'an 710071, China
1 shared publication Leiqin He
School of Aerospace Science and Technology, Xidian University 1 , Xi'an 710071, China
1 shared publication
Latest Publications
- Open Access
- 1 August 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (8)
Analysis of three-dimensional time-varying characteristics of subsonic plasma jet
The plasma jet wind tunnel, as a ground simulation device for studying the electromagnetic properties of near-space vehicle sheaths, can help people conduct several studies, such as communications and electronic parameter diagnostics. The plasma produced by a plasma generator has time-dependent variations due to the influence of power supply oscillations, turbulence, and other aspects of the device. To accurately define the experimental state of plasma, it is necessary to carefully analyze the three-dimensional (3D) time-varying characteristics of the plasma jet accurately since the distribution is non-uniform. This paper uses volume tomography technology to reconstruct the time series of the 3D emission field of the plasma jet with high-speed cameras. Then, the time–frequency characteristics, overall instability of the emission intensity, central axis position, and shape of the plasma jet are analyzed. The following characteristics are mainly observed: First, the plasma generator ejects plasma intermittently, which then spirals forward away from the nozzle. Second, the intensity, the radius of central axis movement, and the shape of the plasma jet vary with time at the same low frequency. The magnitude of this frequency is mainly related to the rate of change of the jet's air pressure difference with the vacuum chamber. Third, the overall instability of the plasma jet increases along the axial direction away from the nozzle and radially away from the center of the jet.
- 1 August 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (8)
Open AccessAnalysis of three-dimensional time-varying characteristics of subsonic plasma jet
The plasma jet wind tunnel, as a ground simulation device for studying the electromagnetic properties of near-space vehicle sheaths, can help people conduct several studies, such as communications and electronic parameter diagnostics. The plasma produced by a plasma generator has time-dependent variations due to the influence of power supply oscillations, turbulence, and other aspects of the device. To accurately define the experimental state of plasma, it is necessary to carefully analyze the three-dimensional (3D) time-varying characteristics of the plasma jet accurately since the distribution is non-uniform. This paper uses volume tomography technology to reconstruct the time series of the 3D emission field of the plasma jet with high-speed cameras. Then, the time–frequency characteristics, overall instability of the emission intensity, central axis position, and shape of the plasma jet are analyzed. The following characteristics are mainly observed: First, the plasma generator ejects plasma intermittently, which then spirals forward away from the nozzle. Second, the intensity, the radius of central axis movement, and the shape of the plasma jet vary with time at the same low frequency. The magnitude of this frequency is mainly related to the rate of change of the jet's air pressure difference with the vacuum chamber. Third, the overall instability of the plasma jet increases along the axial direction away from the nozzle and radially away from the center of the jet.
- Open Access
- 1 August 2023
- Published by AIP Publishing in Physics of Plasmas
- Vol. 30 (8)
Three-dimensional reconstruction of the emission field of the inductively coupled plasma jet
Three-dimensional plasma diagnosis is crucial for understanding the distribution of the physical parameters of inhomogeneous plasma. Optical emission spectroscopy (OES) can obtain the electron temperature and density by spectrum lines. The premise of the 3D diagnosis by OES is to obtain the 3D emission field of plasma at different wavelengths. In this paper, we studied how to reconstruct the 3D emission field of the inductively coupled plasma (ICP) jet. The purpose of this work is to provide an imaging basis for the future 3D diagnosis of plasma. Volume tomography can directly reconstruct the 3D emission field by two-dimensional images from multiple perspectives, so it is used to reconstruct the 3D emission field of the ICP jet. During the reconstruction, the Monte Carlo method is used to calculate the weight coefficient. In order to solve the ill-posed linear equations involving a large-size weight matrix fast, we first compared the performance of three inversion algorithms in terms of different aspects and then proposed the multiscale calculation method to reduce the size of the weight matrix. We eventually established a 3D reconstruction system to obtain the 3D emission field of the ICP jets at different powers with 5 mm spatial resolution, based upon which we demonstrated the non-uniform structure of the ICP jet. The re-projection error of the ICP jet reconstructed verifies the high reconstruction accuracy of the proposed method.
- 1 August 2023
- Published by AIP Publishing in Physics of Plasmas
- Vol. 30 (8)
Open AccessThree-dimensional reconstruction of the emission field of the inductively coupled plasma jet
Three-dimensional plasma diagnosis is crucial for understanding the distribution of the physical parameters of inhomogeneous plasma. Optical emission spectroscopy (OES) can obtain the electron temperature and density by spectrum lines. The premise of the 3D diagnosis by OES is to obtain the 3D emission field of plasma at different wavelengths. In this paper, we studied how to reconstruct the 3D emission field of the inductively coupled plasma (ICP) jet. The purpose of this work is to provide an imaging basis for the future 3D diagnosis of plasma. Volume tomography can directly reconstruct the 3D emission field by two-dimensional images from multiple perspectives, so it is used to reconstruct the 3D emission field of the ICP jet. During the reconstruction, the Monte Carlo method is used to calculate the weight coefficient. In order to solve the ill-posed linear equations involving a large-size weight matrix fast, we first compared the performance of three inversion algorithms in terms of different aspects and then proposed the multiscale calculation method to reduce the size of the weight matrix. We eventually established a 3D reconstruction system to obtain the 3D emission field of the ICP jets at different powers with 5 mm spatial resolution, based upon which we demonstrated the non-uniform structure of the ICP jet. The re-projection error of the ICP jet reconstructed verifies the high reconstruction accuracy of the proposed method.
- 1 February 2021
- Published by AIP Publishing in Physics of Plasmas
- Vol. 28 (2) , 023503
Simulation of pulsed electron-beam emission from a triggered multi-gap pseudospark device
Results simulating time-resolved pulsed electron-beam emission from a triggered four-gap pseudospark device are presented. It is important for many applications to explore the mechanisms of the pulsed electron-beam current generated in the multi-gap pseudospark discharge devices. From experiments, it is known that the pulsed emitted electron pulse is principally at the beginning, characterized by a rather short part of high energetic electrons followed by a broad pulse of electrons with an average energy of half of applied voltage. These characteristics of the electron-beam current have been simulated for a four-gap pseudospark discharge device with anode voltages from 20 to 50 kV, and with Ar as working gas in a pressure range from 20 to 60 Pa. According to the results, when the pressure becomes higher than a specific threshold, the two peaks are found to merge together. When the anode voltage is 20 kV, the pressure threshold is about 30 Pa. When the anode voltage is above 30 kV, the pressure threshold is about 40 Pa. It is observed that the energy spectrum of the high-energetic part of pulsed electron-beam contains a large peak corresponding to several keVs in the initial stage, and then it shifts toward lower energies. From the simulation, this specific characteristic is verified that the time duration of the high-energetic part of the pulsed electron-beam current grows with increasing anode voltage and decreasing pressure.
- 1 February 2021
- Published by AIP Publishing in Physics of Plasmas
- Vol. 28 (2) , 023503
Simulation of pulsed electron-beam emission from a triggered multi-gap pseudospark device
Results simulating time-resolved pulsed electron-beam emission from a triggered four-gap pseudospark device are presented. It is important for many applications to explore the mechanisms of the pulsed electron-beam current generated in the multi-gap pseudospark discharge devices. From experiments, it is known that the pulsed emitted electron pulse is principally at the beginning, characterized by a rather short part of high energetic electrons followed by a broad pulse of electrons with an average energy of half of applied voltage. These characteristics of the electron-beam current have been simulated for a four-gap pseudospark discharge device with anode voltages from 20 to 50 kV, and with Ar as working gas in a pressure range from 20 to 60 Pa. According to the results, when the pressure becomes higher than a specific threshold, the two peaks are found to merge together. When the anode voltage is 20 kV, the pressure threshold is about 30 Pa. When the anode voltage is above 30 kV, the pressure threshold is about 40 Pa. It is observed that the energy spectrum of the high-energetic part of pulsed electron-beam contains a large peak corresponding to several keVs in the initial stage, and then it shifts toward lower energies. From the simulation, this specific characteristic is verified that the time duration of the high-energetic part of the pulsed electron-beam current grows with increasing anode voltage and decreasing pressure.
- Open Access
- 1 January 2015
- Published by Sociedad Espanola de Patologia Digestiva (SEPD) in Revista Española de Enfermedades Digestivas
- Vol. 108 (5) , 283-4
Primary squamous cell carcinoma of the stomach presenting as a huge retroperitoneal tumor: A case report
A man complained of upper abdominal pain and early satiety for one month. An upper gastrointestinal endoscopy showed nothing specia. A CT scan of the abdomen was perfromed, which demonstrated a huge heterogeneous retroperitoneal mass close to the dorsal wall of the stomach and surrounding the abdominal aortic and celiac trunk. The resected specimen suggested that an un-regular tumor invaded to the dorsal wall of the stomach. Postoperative histological examination confirmed that it was a gastric squamous cell carcinoma.
- 1 January 2015
- Published by Sociedad Espanola de Patologia Digestiva (SEPD) in Revista Española de Enfermedades Digestivas
- Vol. 108 (5) , 283-4
Open AccessPrimary squamous cell carcinoma of the stomach presenting as a huge retroperitoneal tumor: A case report
A man complained of upper abdominal pain and early satiety for one month. An upper gastrointestinal endoscopy showed nothing specia. A CT scan of the abdomen was perfromed, which demonstrated a huge heterogeneous retroperitoneal mass close to the dorsal wall of the stomach and surrounding the abdominal aortic and celiac trunk. The resected specimen suggested that an un-regular tumor invaded to the dorsal wall of the stomach. Postoperative histological examination confirmed that it was a gastric squamous cell carcinoma.