Shuhao Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shuhao Zhao has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Niancai Peng
State Key Laboratory for Manufacturing Systems Engineering, Xi’an Jiaotong University, Xi’an 710054, Shaanxi, China
3 shared publications Fei Hu
State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University No. 99, Yanxiang Road, Xi'an, 710054, P. R. China
2 shared publicationsJunjun Wu
State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University No. 99, Yanxiang Road, Xi'an, 710054, P. R. China
2 shared publicationsZengming Zhang
State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University No. 99, Yanxiang Road, Xi'an, 710054, P. R. China
2 shared publications- Fei Hu
School of Instrument Science and Technology, State Key Laboratory for Manufacturing System Engineering, Xi'an Jiaotong University, Xi'an, 710049, Shaanxi, PR China; State Industry-Education Integration Center for Medical Innovations, Xi'an Jiaotong University, Xi'an, 710054, Shaanxi, PR China; Key Laboratory of Advanced Biological Detection Technologies and Instruments of Shaanxi Province, Xi'an Jiaotong University, Xi'an, 710054, Shaanxi, PR China
1 shared publication Lei Jiang
State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University No. 99, Yanxiang Road, Xi'an, 710054, P. R. China
1 shared publication
Latest Publications
- 7 June 2023
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 148 (13) , 3065-3073
A one-stage deep learning based method for automatic analysis of droplet-based digital PCR images
A novel method with high accuracy and lower resource consumption for droplets detection and can be used on mobile devices.
- 7 June 2023
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 148 (13) , 3065-3073
A one-stage deep learning based method for automatic analysis of droplet-based digital PCR images
A novel method with high accuracy and lower resource consumption for droplets detection and can be used on mobile devices.
- 20 September 2022
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 147 (21) , 4876-4887
A sample-to-answer DNA detection microfluidic system integrating sample pretreatment and smartphone-readable gradient plasmonic photothermal continuous-flow PCR
As the gold standard for nucleic acid detection, full-process polymerase chain reaction (PCR) analysis often falls into the dilemma of complex workflow, time-consuming, and high equipment costs. Therefore, we designed and optimized a DNA quantification microfluidic system by strategically integrating sample pretreatment and a smartphone-readable gradient plasmonic photothermal (GPPT) continuous-flow PCR (CF-PCR). Through preloading and sequential injection of immiscible extraction reagents, combined with magnetic bead (MB) manipulation, the microfluidic chip successfully purified and concentrated 100 μL of HBV-DNA spiked plasma into a 20-μL purified sample within 14 minutes. With a digital PCR platform, the optimized experiments showed that the DNA extraction efficiency can reach 69% at an immiscible reagent configuration ratio of 10 : 10 : 1 : 12 : 2 (sample : lysis/binding buffer : MB : silicone oil : eluent) and a flow rate of 25 μL min−1. For the first time, we used gold nanorod (AuNR)-doped PDMS to prepare a CF-PCR submodule for the amplification of a 40 μL PCR mixture. Due to the plasmonic photothermal effect of AuNRs and the gradient intensity of an expanded laser spot, the PCR thermal gradient was formed on a coin-sized area. The compact annular thermal-microfluidic layout, optimized DNA dye concentration, and chip transmittance synergistically enable a rarely reported smartphone-based fluorescence CF-PCR, greatly simplifying thermal control and detection setup. Prototype construction and validation experiments show that the microsystem can complete the sample-to-answer quantification of HBV-DNA with a dynamic linear range from 1.2 × 101 to 1.2 × 106 copies per μL in ∼37 minutes. This novel microfluidic solution effectively bridges the technical gap between the CF-PCR, sample pretreatment and result characterization, making the workflow standardized and rapid and requiring <15% of the commercial instrument cost. The simplicity, rapidity and low cost of this work make it promising for applications in decentralized laboratories and low-resource settings.
- 20 September 2022
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 147 (21) , 4876-4887
A sample-to-answer DNA detection microfluidic system integrating sample pretreatment and smartphone-readable gradient plasmonic photothermal continuous-flow PCR
As the gold standard for nucleic acid detection, full-process polymerase chain reaction (PCR) analysis often falls into the dilemma of complex workflow, time-consuming, and high equipment costs. Therefore, we designed and optimized a DNA quantification microfluidic system by strategically integrating sample pretreatment and a smartphone-readable gradient plasmonic photothermal (GPPT) continuous-flow PCR (CF-PCR). Through preloading and sequential injection of immiscible extraction reagents, combined with magnetic bead (MB) manipulation, the microfluidic chip successfully purified and concentrated 100 μL of HBV-DNA spiked plasma into a 20-μL purified sample within 14 minutes. With a digital PCR platform, the optimized experiments showed that the DNA extraction efficiency can reach 69% at an immiscible reagent configuration ratio of 10 : 10 : 1 : 12 : 2 (sample : lysis/binding buffer : MB : silicone oil : eluent) and a flow rate of 25 μL min−1. For the first time, we used gold nanorod (AuNR)-doped PDMS to prepare a CF-PCR submodule for the amplification of a 40 μL PCR mixture. Due to the plasmonic photothermal effect of AuNRs and the gradient intensity of an expanded laser spot, the PCR thermal gradient was formed on a coin-sized area. The compact annular thermal-microfluidic layout, optimized DNA dye concentration, and chip transmittance synergistically enable a rarely reported smartphone-based fluorescence CF-PCR, greatly simplifying thermal control and detection setup. Prototype construction and validation experiments show that the microsystem can complete the sample-to-answer quantification of HBV-DNA with a dynamic linear range from 1.2 × 101 to 1.2 × 106 copies per μL in ∼37 minutes. This novel microfluidic solution effectively bridges the technical gap between the CF-PCR, sample pretreatment and result characterization, making the workflow standardized and rapid and requiring <15% of the commercial instrument cost. The simplicity, rapidity and low cost of this work make it promising for applications in decentralized laboratories and low-resource settings.
- 23 December 2020
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 146 (5) , 1559-1568
Massive droplet generation for digital PCR via a smart step emulsification chip integrated in a reaction tube
A compact device integrating a smart chip with a reaction tube is used to prepare monodisperse droplets for ddPCR.
- 23 December 2020
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 146 (5) , 1559-1568
Massive droplet generation for digital PCR via a smart step emulsification chip integrated in a reaction tube
A compact device integrating a smart chip with a reaction tube is used to prepare monodisperse droplets for ddPCR.