THThomas Heisser

Thomas Heisser

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Thomas Heisser has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Consistent Major Differences in Sex- and Age-Specific Diagnostic Performance among Nine Faecal Immunochemical Tests Used for Colorectal Cancer Screening

    by Anton Gies, Tobias Niedermaier, Elizabeth Alwers, Thomas Hielscher, Korbinian Weigl, Thomas Heisser, Petra Schrotz-King, Michael Hoffmeister, Hermann Brenner

    Evidence on diagnostic performance of faecal immunochemical tests (FITs) by sex and age is scarce. We aimed to evaluate FIT performance for detection of advanced colorectal neoplasia (AN) by sex and age across nine different FIT brands in a colonoscopy-controlled setting. The faecal samples were obtained from 2042 participants of colonoscopy screening. All eligible cases with AN (n = 216) and 300 randomly selected participants without AN were included. Diagnostic performance for detection of AN was assessed by sex and age (50–64 vs. 65–79 years for each of the nine FITs individually and for all FITs combined. Sensitivity was consistently lower, and specificity was consistently higher for females as compared with males (pooled values at original FIT cutoffs, 25.7% vs. 34.6%, p = 0.12 and 96.2% vs. 90.8%, p < 0.01, respectively). Positive predictive values (PPVs) were similar between both sexes, but negative predictive values (NPVs) were consistently higher for females (pooled values, 91.8% vs. 86.6%, p < 0.01). Sex-specific cutoffs attenuated differences in sensitivities but increased differences in predictive values. According to age, sensitivities and specificities were similar, whereas PPVs were consistently lower and NPVs were consistently higher for the younger participants. A negative FIT is less reliable in ruling out AN among men than among women and among older than among younger participants. Comparisons of measures of diagnostic performance among studies with different sex or age distributions should be interpreted with caution.


  • Open Access

    The Effects of Different Invitation Schemes on the Use of Fecal Occult Blood Tests for Colorectal Cancer Screening: Systematic Review of Randomized Controlled Trials

    by Laura F. Gruner, Efrat L. Amitay, Thomas Heisser, Feng Guo, Tobias Niedermaier, Anton Gies, Michael Hoffmeister, Hermann Brenner

    Personal invitations for fecal occult blood tests (nowadays mostly fecal immunochemical tests) are increasingly used to raise their usage for colorectal cancer screening. However, there is a large heterogeneity in applied invitation schemes. We aimed to review evidence for the effectiveness of various invitation schemes. The main outcome was the fecal occult blood test usage rate. A systematic search was performed in Medline and Web of Science (up to 9 July 2020). Randomized controlled trials or cluster-randomized controlled trials were eligible, which reported on general invitations for fecal occult blood test-based colorectal cancer screening sent to the general population at average colorectal cancer risk. (PROSPERO 2020 CRD42020169409). Overall, 34 studies were included. Invitations with an attached, i.e., mailed fecal occult blood test consistently increased test usage by 4–19.7% points, compared to other methods of test provision. Likewise, the introduction of advance notification consistently led to a higher usage rate, with an increase of 3.3–10.8% points. Reminders showed positive but varying effects by method. With an increase of 8.5–15.8% points, letter or email reminders were more effective than reminders by phone call or text message (0.6–6.5% points). Inconsistent results were found for financial incentives ((−8.4)–20% points) and for added or changed invitation material ((−3.5)–11.8% points). With 3.5–24.7% points, the strongest increases in use were achieved by multifaceted invitation, implementing multiple components. Any invitation scheme was superior over no invitation. Advance notification, mailing of fecal occult blood test, and reminders were consistently shown to have major, complementary potential to increase participation in fecal occult blood test-based colorectal cancer screening settings.


  • Open Access

    Fecal Immunochemical Tests Detect Screening Participants with Multiple Advanced Adenomas Better than T1 Colorectal Cancers

    by Anton Gies, Tobias Niedermaier, Laura Fiona Gruner, Thomas Heisser, Petra Schrotz-King, Hermann Brenner

    Background: Fecal immunochemical tests (FITs) are widely used for colorectal cancer (CRC) screening. The detection of early-stage cancer and advanced adenoma (AA), the most important premalignant lesion, is highly relevant to reducing CRC-related deaths. We aimed to assess sensitivity for the detection of CRC and AA stratified by tumor stage; number; size; histology of AA; and by location, age, sex, and body mass index (BMI). Methods: Participants of screening colonoscopy (n = 2043) and newly diagnosed CRC patients (n = 184) provided a stool sample before bowel preparation or CRC surgery. Fecal hemoglobin concentration was determined in parallel by nine different quantitative FITs among 94 CRC patients, 200 AA cases, and 300 participants free of advanced neoplasm. Sensitivities were calculated at original cutoffs and at adjusted cutoffs, yielding 93% specificity among all FITs. Results: At adjusted cutoffs, UICC stage I cancers yielded consistently lower sensitivities (range: 62–68%) compared to stage II–IV cancers (range: 73–89%). An even stronger gradient was observed according to T status, with substantially lower sensitivities for T1 (range: 39–57%) than for T2–T4 cancers (range: 71–100%). Sensitivities for the detection of participants with multiple AAs ranged from 55% to 64% and were by up to 25% points higher than sensitivities for T1 cancers. Conclusions: FITs detect stage I cancers and especially T1 cancers at substantially lower sensitivities than more advanced cancer stages. Participants with multiple AAs were detected with slightly lower sensitivities than stage I cancers and with even higher sensitivities than T1 cancers. Further research should focus on improving the detection of early-stage cancers.