Gholamhossein Shirkoohi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Gholamhossein Shirkoohi has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Mohammad Osman Tokhi
London South Bank University
6 shared publications - Fang Duan
School of Engineering, London South Bank University, London, U.K
3 shared publications - Faris Nafiah
School of Engineering, London South Bank University, London, U.K
3 shared publications - Zhanfang Zhao
School of Engineering, London South Bank University, London, U.K
3 shared publications - John Rudlin
TWI Ltd., Cambridge CB21 6AL, UK
2 shared publications Owen Rees-Lloyd
TWI Ltd., Cambridge, U.K
2 shared publications
Latest Publications
- Open Access
Reliability Improvement of Magnetic Corrosion Monitor for Long-Term Applications
Electromagnetic techniques are widely employed for corrosion detection, and their performance for inspection of corrosion is well established. However, limited work is carried out on the development and reliability of smart corrosion monitoring devices for tracking internal or buried thickness loss due to corrosion remotely. A novel smart magnetic corrosion transducer is developed for long-term monitoring of thickness loss due to corrosion at critical locations. The reliability of the transducer is enhanced by using a dissimilar active redundancy approach. The improved corrosion monitor has been tested in the ambient environment for seven months to evaluate the stability against environmental factors and degradation. The monitor is found to show great sensitivity to detect defects due to corrosion. Detection of anomalous patterns in the time series data received from the monitors is accomplished by using Pearson’s correlation coefficient. The critical component of the monitor is identified at the end of the test. Research findings reveal that, compared to the existing corrosion monitoring techniques in the industry, the detection and isolation of faulty sensor features introduced in this study can contribute to reliable monitoring of thickness loss due to corrosion in ferromagnetic structures over an extended period of time.
Open AccessReliability Improvement of Magnetic Corrosion Monitor for Long-Term Applications
Electromagnetic techniques are widely employed for corrosion detection, and their performance for inspection of corrosion is well established. However, limited work is carried out on the development and reliability of smart corrosion monitoring devices for tracking internal or buried thickness loss due to corrosion remotely. A novel smart magnetic corrosion transducer is developed for long-term monitoring of thickness loss due to corrosion at critical locations. The reliability of the transducer is enhanced by using a dissimilar active redundancy approach. The improved corrosion monitor has been tested in the ambient environment for seven months to evaluate the stability against environmental factors and degradation. The monitor is found to show great sensitivity to detect defects due to corrosion. Detection of anomalous patterns in the time series data received from the monitors is accomplished by using Pearson’s correlation coefficient. The critical component of the monitor is identified at the end of the test. Research findings reveal that, compared to the existing corrosion monitoring techniques in the industry, the detection and isolation of faulty sensor features introduced in this study can contribute to reliable monitoring of thickness loss due to corrosion in ferromagnetic structures over an extended period of time.
- Open Access
- 20 January 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (3) , 1037
Development of Permanently Installed Magnetic Eddy Current Sensor for Corrosion Monitoring of Ferromagnetic Pipelines
Permanently installed sensors are a cost-effective solution for corrosion monitoring due to their advantages, such as less human interference and continuous data acquisition. Some of the most widely used permanently installed corrosion sensors are ultrasonic thickness (UT) gauges. However, UT sensors are limited by the need for coupling agents between pipe surfaces and sensors. The magnetic eddy current (MEC) method, on the other hand, does not require couplant and can be used over insulations. With the development of powerful rare earth magnets, MEC sensors with low power consumption are possible, and there is the prospect of using them as permanently installed sensors. A novel wireless magnetic eddy current sensor has been designed and optimized using finite element simulation. Sensitivity studies of the sensors reveal that the excitation frequency is a critical parameter for the detection of corrosion defects. An in-depth explanation of the relationship between the sensitivity of the sensor and the excitation frequency is presented in this paper. The results of an accelerated corrosion test, conducted to simulate the service environment of the sensor, are also discussed. It was observed that the sensor signals are very sensitive to corrosion defects and show no subtle differences due to temperature and humidity changes.
- 20 January 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (3) , 1037
Open AccessDevelopment of Permanently Installed Magnetic Eddy Current Sensor for Corrosion Monitoring of Ferromagnetic Pipelines
Permanently installed sensors are a cost-effective solution for corrosion monitoring due to their advantages, such as less human interference and continuous data acquisition. Some of the most widely used permanently installed corrosion sensors are ultrasonic thickness (UT) gauges. However, UT sensors are limited by the need for coupling agents between pipe surfaces and sensors. The magnetic eddy current (MEC) method, on the other hand, does not require couplant and can be used over insulations. With the development of powerful rare earth magnets, MEC sensors with low power consumption are possible, and there is the prospect of using them as permanently installed sensors. A novel wireless magnetic eddy current sensor has been designed and optimized using finite element simulation. Sensitivity studies of the sensors reveal that the excitation frequency is a critical parameter for the detection of corrosion defects. An in-depth explanation of the relationship between the sensitivity of the sensor and the excitation frequency is presented in this paper. The results of an accelerated corrosion test, conducted to simulate the service environment of the sensor, are also discussed. It was observed that the sensor signals are very sensitive to corrosion defects and show no subtle differences due to temperature and humidity changes.
- 11 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (22) , 26124-26131
Determining Feature Extraction Parameters for Pulsed Eddy Current Sensor: A Minimisation Problem Approach
Pulsed eddy current (PEC) is an electromagnetic non-destructive testing (NDT) technique mainly used to inspect corrosion in pipelines. Like many other NDT techniques, to quantify pipe wall thickness, a signal feature has to be extracted from the PEC response. The authors’ previous work has exploited the linear relationship of the time-derivative feature to propose an in-situ calibration routine. However, to extract the time-derivative feature, two configuration parameters need to be determined prior to feature extraction. To the authors’ knowledge, none of the previous works explores the determining factors of this configuration parameters, where the current technique is still limited to using brute force method or trial-and-error. This paper brings novelty by formulating the aforementioned problem as a minimisation problem, and solving it using a particle swarm optimisation (PSO) algorithm. The obtained results, compared against brute force method, demonstrate the feasibility and performance improvement of using PSO in determining the configuration parameters. The approach thus presented is validated and the results obtained are justified by analysing the underlying physical system theory.
- 11 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (22) , 26124-26131
Determining Feature Extraction Parameters for Pulsed Eddy Current Sensor: A Minimisation Problem Approach
Pulsed eddy current (PEC) is an electromagnetic non-destructive testing (NDT) technique mainly used to inspect corrosion in pipelines. Like many other NDT techniques, to quantify pipe wall thickness, a signal feature has to be extracted from the PEC response. The authors’ previous work has exploited the linear relationship of the time-derivative feature to propose an in-situ calibration routine. However, to extract the time-derivative feature, two configuration parameters need to be determined prior to feature extraction. To the authors’ knowledge, none of the previous works explores the determining factors of this configuration parameters, where the current technique is still limited to using brute force method or trial-and-error. This paper brings novelty by formulating the aforementioned problem as a minimisation problem, and solving it using a particle swarm optimisation (PSO) algorithm. The obtained results, compared against brute force method, demonstrate the feasibility and performance improvement of using PSO in determining the configuration parameters. The approach thus presented is validated and the results obtained are justified by analysing the underlying physical system theory.
- 27 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (19) , 22011-22018
Decoupling the Influence of Wall Thinning and Cladding Thickness Variations in Pulsed Eddy Current Using Principal Component Analysis
Corrosion may develop and grow on steel pipes under layers of insulation and cladding. Inspection of the pipes through these protective layers is of paramount importance. Pulsed eddy current (PEC) is a primary non-destructive testing (NDT) technique candidate for this type of inspection as it requires no contact with the inspection material. To overcome the variability in PEC signals due to variations in the cladding thickness, a large measurement set is analysed in this paper using principal component analysis (PCA). The PCA approach decomposes the signal set into a number of uncorrelated variables that explain the maximum amount of the variance in the data set, in which, in this respect, efficiently separate the influences contributed by the difference in the material properties of cladding and pipe wall. The feasibility of using PCA to quantify simulated steel pipe wall independent of confounding cladding thickness variations is investigated. It is found that, with sufficient amount of data, the approach can effectively separate the influences contributed by the wall thickness variations from the cladding thickness variations.
- 27 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (19) , 22011-22018
Decoupling the Influence of Wall Thinning and Cladding Thickness Variations in Pulsed Eddy Current Using Principal Component Analysis
Corrosion may develop and grow on steel pipes under layers of insulation and cladding. Inspection of the pipes through these protective layers is of paramount importance. Pulsed eddy current (PEC) is a primary non-destructive testing (NDT) technique candidate for this type of inspection as it requires no contact with the inspection material. To overcome the variability in PEC signals due to variations in the cladding thickness, a large measurement set is analysed in this paper using principal component analysis (PCA). The PCA approach decomposes the signal set into a number of uncorrelated variables that explain the maximum amount of the variance in the data set, in which, in this respect, efficiently separate the influences contributed by the difference in the material properties of cladding and pipe wall. The feasibility of using PCA to quantify simulated steel pipe wall independent of confounding cladding thickness variations is investigated. It is found that, with sufficient amount of data, the approach can effectively separate the influences contributed by the wall thickness variations from the cladding thickness variations.
- Open Access
Development of an MFL Coil Sensor for Testing Pipes in Extreme Temperature Conditions
This paper aims to design a coil sensor for corrosion monitoring of industrial pipes that could detect variations in thickness using the MFL (Magnetic Flux Leakage) technique. An MFL coil sensor is designed and tested with pipe sample thicknesses of 2, 4, 6, and 8 mm based on the magnetic field effect of ferrite cores. Moreover, a measurement setup for analysing pipe samples up to a temperature of 200° Celsius is suggested. Experimental results reveal that the MFL coil sensor can fulfil the requirements for MFL testing of pipes in high temperature conditions, and that the precision of MFL monitoring of pipes to detect corrosion at high temperatures can be improved significantly.
Open AccessDevelopment of an MFL Coil Sensor for Testing Pipes in Extreme Temperature Conditions
This paper aims to design a coil sensor for corrosion monitoring of industrial pipes that could detect variations in thickness using the MFL (Magnetic Flux Leakage) technique. An MFL coil sensor is designed and tested with pipe sample thicknesses of 2, 4, 6, and 8 mm based on the magnetic field effect of ferrite cores. Moreover, a measurement setup for analysing pipe samples up to a temperature of 200° Celsius is suggested. Experimental results reveal that the MFL coil sensor can fulfil the requirements for MFL testing of pipes in high temperature conditions, and that the precision of MFL monitoring of pipes to detect corrosion at high temperatures can be improved significantly.
- 9 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (5) , 6897-6903
Parameter Analysis of Pulsed Eddy Current Sensor Using Principal Component Analysis
Pulsed eddy current (PEC) technique provides a means to inspect structures without surface contact. It is particularly useful when the structure's surface is rough or inaccessible, such as insulated pipes in pipeline. Probe parameters of a PEC system, especially the sensing and excitation coil diameters, can significantly affect the PEC system's performance. Thus, detailed analysis of these parameters is paramount in developing a PEC system. Currently, this is accomplished by establishing the trend of features with respect to the analyzed variables, e.g. sample thicknesses. However, prior to extracting these features, a number of configuration parameters have to be determined. For this reason, analyzing PEC performance over a range of coil diameter values is rather time-consuming as both the sensing and excitation coil diameters significantly affect the received signals. Principal component analysis (PCA) is proposed as an alternative to the feature extraction. The work here analyzes the trends contributed by the PCA scores for different values of sensing and excitation coil parameters. Results from both numerical simulations and experiments suggest that the sensitivity of the PEC probe is highly correlated with the excitation coil diameter, while the excitation-sensing coil distance is not significant in determining the sensitivity of the PEC probe. These findings are consistent with those reported in the literature, suggesting the potential of adopting PCA for an automated PEC performance analysis process.
- 9 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (5) , 6897-6903
Parameter Analysis of Pulsed Eddy Current Sensor Using Principal Component Analysis
Pulsed eddy current (PEC) technique provides a means to inspect structures without surface contact. It is particularly useful when the structure's surface is rough or inaccessible, such as insulated pipes in pipeline. Probe parameters of a PEC system, especially the sensing and excitation coil diameters, can significantly affect the PEC system's performance. Thus, detailed analysis of these parameters is paramount in developing a PEC system. Currently, this is accomplished by establishing the trend of features with respect to the analyzed variables, e.g. sample thicknesses. However, prior to extracting these features, a number of configuration parameters have to be determined. For this reason, analyzing PEC performance over a range of coil diameter values is rather time-consuming as both the sensing and excitation coil diameters significantly affect the received signals. Principal component analysis (PCA) is proposed as an alternative to the feature extraction. The work here analyzes the trends contributed by the PCA scores for different values of sensing and excitation coil parameters. Results from both numerical simulations and experiments suggest that the sensitivity of the PEC probe is highly correlated with the excitation coil diameter, while the excitation-sensing coil distance is not significant in determining the sensitivity of the PEC probe. These findings are consistent with those reported in the literature, suggesting the potential of adopting PCA for an automated PEC performance analysis process.
- Open Access
- 1 March 2015
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 9 (2) , 211-217
Modelling of fault detection in electrical wiring
Electrical wiring and cables, in many cases buried deep, in many systems and environments suffer damage. In some cases the damage only affects wire insulation and is not usually detected under normal operating conditions. This study discusses computer modelling of electrical wires, based on time‐domain reflectometry using trains of successive pulses which were used in order to develop techniques and test procedures that would lead to identification of these types of faults. This study shows detailed simulations of defects in insulation of electrical wires and in cable shields, using dedicated electromagnetic modelling computation software. The results of simulations were compared with those obtained in experimental measurement for wires and cables of several metres in length. Comparison of the analysed measurement results for this novel technique shows clear indication of its relevance to flaw detection in electrical wires, guided through simulation.
- 1 March 2015
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 9 (2) , 211-217
Open AccessModelling of fault detection in electrical wiring
Electrical wiring and cables, in many cases buried deep, in many systems and environments suffer damage. In some cases the damage only affects wire insulation and is not usually detected under normal operating conditions. This study discusses computer modelling of electrical wires, based on time‐domain reflectometry using trains of successive pulses which were used in order to develop techniques and test procedures that would lead to identification of these types of faults. This study shows detailed simulations of defects in insulation of electrical wires and in cable shields, using dedicated electromagnetic modelling computation software. The results of simulations were compared with those obtained in experimental measurement for wires and cables of several metres in length. Comparison of the analysed measurement results for this novel technique shows clear indication of its relevance to flaw detection in electrical wires, guided through simulation.