Xu Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xu Zhang has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Haiwei Liu
School of Electrical and Power Engineering, China University of Mining and Technology, Xuzhou, China
1 shared publication - Ke Yang
School of Electrical and Power Engineering, China University of Mining and Technology, Xuzhou, China
1 shared publication - Xuanfeng Song
School of Electrical and Power Engineering, China University of Mining and Technology, Xuzhou, China
1 shared publication - Yiwen Geng
School of Electrical and Power Engineering, China University of Mining and Technology, Xuzhou, China
1 shared publication
Latest Publications
- 6 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (6) , 7097-7111
Stability Analysis and Key Parameters Design for Grid-Connected Current-Source Inverter With Capacitor-Voltage Feedback Active Damping
In a three-phase grid-connected current-source inverter system with the capacitor-voltage feedback (CVF)-based active damping method, a high-pass filter is usually employed in the CVF loop to mitigate its impact on system dynamics. Meanwhile, the inherent delays in a digital control system brought by pulsewidth modulation (PWM) and the digital control will make stability analysis and parameters design of the control system more complicated. In this article, the impacts of the high-pass filter and the inherent delays are considered for stability analysis and parameters design. The impacts of the cutoff frequency of the high-pass filter and the CVF damping coefficient on the system stability are analyzed in the discrete domain, and an optimal CVF damping coefficient is obtained. Moreover, a key parameters design method for the control system is proposed. The method simplifies the procedure of key parameters designing, which can mitigate the resonance of the system caused by the CL filter effectively with better dynamics and steady state performance. Finally, simulation and experimental results are provided to verify the effectiveness of the proposed method in this article.
- 6 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (6) , 7097-7111
Stability Analysis and Key Parameters Design for Grid-Connected Current-Source Inverter With Capacitor-Voltage Feedback Active Damping
In a three-phase grid-connected current-source inverter system with the capacitor-voltage feedback (CVF)-based active damping method, a high-pass filter is usually employed in the CVF loop to mitigate its impact on system dynamics. Meanwhile, the inherent delays in a digital control system brought by pulsewidth modulation (PWM) and the digital control will make stability analysis and parameters design of the control system more complicated. In this article, the impacts of the high-pass filter and the inherent delays are considered for stability analysis and parameters design. The impacts of the cutoff frequency of the high-pass filter and the CVF damping coefficient on the system stability are analyzed in the discrete domain, and an optimal CVF damping coefficient is obtained. Moreover, a key parameters design method for the control system is proposed. The method simplifies the procedure of key parameters designing, which can mitigate the resonance of the system caused by the CL filter effectively with better dynamics and steady state performance. Finally, simulation and experimental results are provided to verify the effectiveness of the proposed method in this article.