Yanzhe Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yanzhe Yu has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
Wenhua Chen
9 shared publications- Shen Wei
The Bartlett School of Sustainable Construction, University College London (UCL), 1–19 Torrington Place, London WC1E 7HB, UK
8 shared publications Xingguo Guo
7 shared publicationsShijun You
5 shared publications- Tianzhen Ye
School of Environmental Science and Engineering, Tianjin University, Tianjin 300350, China
5 shared publications Huan Zhang
4 shared publications
Latest Publications
- 30 April 2026
- Published by Elsevier in Building and Environment
- Vol. 299
Experimental study on airflow containment and pollutant capture of a push-pull ventilation system in residential kitchens
- 30 April 2026
- Published by Elsevier in Building and Environment
- Vol. 299
Experimental study on airflow containment and pollutant capture of a push-pull ventilation system in residential kitchens
- Open Access
- 5 March 2026
- Published by Elsevier in SSRN Electronic Journal
Experimental study on airflow containment and pollutant capture of a push-pull ventilation system in residential kitchens
This study experimentally investigates the flow characteristics and pollutant containment performance of a new push-pull range hood for residential kitchens. The airflow and particle concentration distributions in the cooking zone under different influencing factors were respectively measured using particle image velocimetry (PIV) and a scattering grayscale method. The results present that the airflow pattern, vorticity and turbulence intensity fields in the cooking zone shift from dominance by cooking thermal plumes to control by the capture jet with a large velocity. The forced convection by the capture jet suppresses the thermal plume and establishes a more organized airflow toward the exhaust outlet. The deflection angle of the capture jet under heating conditions is larger than that under isothermal conditions. The deflection angle increases with the exhaust flowrate, and decreases with the jet velocity. Empirical linear models for jet centerline trajectory and velocity decay can describe these relationships. The simulated cooking operation disturbance enlarged the entrainment radius of the jet and the area of particle clusters. However, it had a negligible effect on the deflection angle and trajectory of the jet centerline. The cooking operation disturbances reduced the total particles capture efficiency (CE) by up to 5% and the reduction is increased with the disturbance speed. The ventilation system exhibited optimal containment and capture performance with a jet velocity of 0.8 m/s, achieving total CEs of 95.9%-97.1% at exhaust flowrates of 360-480 m³/h. The new ventilation system improves total CE by up to 14% compared to corresponding cases without the capture jet.
- 5 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessExperimental study on airflow containment and pollutant capture of a push-pull ventilation system in residential kitchens
This study experimentally investigates the flow characteristics and pollutant containment performance of a new push-pull range hood for residential kitchens. The airflow and particle concentration distributions in the cooking zone under different influencing factors were respectively measured using particle image velocimetry (PIV) and a scattering grayscale method. The results present that the airflow pattern, vorticity and turbulence intensity fields in the cooking zone shift from dominance by cooking thermal plumes to control by the capture jet with a large velocity. The forced convection by the capture jet suppresses the thermal plume and establishes a more organized airflow toward the exhaust outlet. The deflection angle of the capture jet under heating conditions is larger than that under isothermal conditions. The deflection angle increases with the exhaust flowrate, and decreases with the jet velocity. Empirical linear models for jet centerline trajectory and velocity decay can describe these relationships. The simulated cooking operation disturbance enlarged the entrainment radius of the jet and the area of particle clusters. However, it had a negligible effect on the deflection angle and trajectory of the jet centerline. The cooking operation disturbances reduced the total particles capture efficiency (CE) by up to 5% and the reduction is increased with the disturbance speed. The ventilation system exhibited optimal containment and capture performance with a jet velocity of 0.8 m/s, achieving total CEs of 95.9%-97.1% at exhaust flowrates of 360-480 m³/h. The new ventilation system improves total CE by up to 14% compared to corresponding cases without the capture jet.
- Top Cited Papers
A multi-objective optimization strategy for ultra-low energy residential buildings based on a hybrid machine learning algorithm
- 19 March 2025
- Published by Elsevier in Journal of Building Engineering
- Vol. 105
An empirical study estimating train-induced airflow rate and its effect on the cooling load of underground stations
- 19 March 2025
- Published by Elsevier in Journal of Building Engineering
- Vol. 105
An empirical study estimating train-induced airflow rate and its effect on the cooling load of underground stations
- 19 June 2024
- Published by Elsevier in Journal of Cleaner Production
- Vol. 467
A simplified modeling method for studying the thermal performance of buildings with vertical greening systems
- 19 June 2024
- Published by Elsevier in Journal of Cleaner Production
- Vol. 467
A simplified modeling method for studying the thermal performance of buildings with vertical greening systems
- Open Access
- 29 October 2023
- Published by Wiley in Energy Science & Engineering
- Vol. 11 (12) , 4408-4420
Characteristics and assessment of the electricity consumption of metro systems: A case study of Tianjin, China
Owing to the complexity of metros, the energy consumption characteristics of metro systems exhibit variability and the energy‐saving management of the systems encounters challenges. To encapsulate the essential characteristics of energy usage and to objectively assess the energy performance of metro systems, this study presents a generalized framework and applies it to a case study conducted in Tianjin. The study also employs correlation analysis to investigate the applicability of the indicators relevant to ridership. The results indicate that the monthly traction electricity consumption exhibits slight variation, while station electricity usage demonstrates substantial fluctuation with seasonal changes. For Tianjin Metro, the passenger factor hardly shows any effect on the electricity use of metro lines. The median value of traction electricity use is approximately 2.0 kWh/(car‐km) and that of the average annual station electricity use of underground lines ranges from 95 to 155 kWh/m2. The emission from the traction sector is 12.2 kgCO2/(vehicle‐km) and from the station sector is 118.6 kgCO2/m2. The study also identifies the energy‐intensive lines of the Tianjin Metro and compares the energy utilization among various global metro systems. The authors hope that this study can help shed light on the assessment of the energy status of metro systems and serve as a source of information for other City‐Metros to implement energy‐saving management.
- 29 October 2023
- Published by Wiley in Energy Science & Engineering
- Vol. 11 (12) , 4408-4420
Open AccessCharacteristics and assessment of the electricity consumption of metro systems: A case study of Tianjin, China
Owing to the complexity of metros, the energy consumption characteristics of metro systems exhibit variability and the energy‐saving management of the systems encounters challenges. To encapsulate the essential characteristics of energy usage and to objectively assess the energy performance of metro systems, this study presents a generalized framework and applies it to a case study conducted in Tianjin. The study also employs correlation analysis to investigate the applicability of the indicators relevant to ridership. The results indicate that the monthly traction electricity consumption exhibits slight variation, while station electricity usage demonstrates substantial fluctuation with seasonal changes. For Tianjin Metro, the passenger factor hardly shows any effect on the electricity use of metro lines. The median value of traction electricity use is approximately 2.0 kWh/(car‐km) and that of the average annual station electricity use of underground lines ranges from 95 to 155 kWh/m2. The emission from the traction sector is 12.2 kgCO2/(vehicle‐km) and from the station sector is 118.6 kgCO2/m2. The study also identifies the energy‐intensive lines of the Tianjin Metro and compares the energy utilization among various global metro systems. The authors hope that this study can help shed light on the assessment of the energy status of metro systems and serve as a source of information for other City‐Metros to implement energy‐saving management.