Milad Behzadi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Milad Behzadi has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Fathollah Ommi
Department of Mechanical Engineering, Tarbiat Modares University, Tehran, Iran
2 shared publications E. Movahednejad
Department of Aerospace, Faculty of Mechanical Engineering, Tarbiat Modares University, Tehran, Iran
1 shared publicationF. Ommi
Department of Aerospace, Faculty of Mechanical Engineering, Tarbiat Modares University, Tehran, Iran
1 shared publication- Mohammad Hasan Ahmadi
Aerospace Department, School of Mechanical Engineering, Tarbiat Modares University, Tehran, Iran
1 shared publication Seyed Hamzeh Siyadat
K. N. Toosi University of Technology, Tehran, Islamic Republic of Iran
1 shared publicationZoheir Saboohi
A&S Institute, Ministry of Science, Research, and Technology, Tehran, Islamic Republic of Iran
1 shared publication
Latest Publications
- 13 October 2023
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 148 (22) , 12877-12890
Study of the acoustic response of a swirl/bluff-body stabilized natural gas flame: experimental aspects and theoretical rationale
- 13 October 2023
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 148 (22) , 12877-12890
Study of the acoustic response of a swirl/bluff-body stabilized natural gas flame: experimental aspects and theoretical rationale
- 5 February 2021
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 147 (2) , 1583-1596
Study of the effect of bluff body size on stability limits of a premixed natural gas swirl burner
- 5 February 2021
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 147 (2) , 1583-1596
Study of the effect of bluff body size on stability limits of a premixed natural gas swirl burner
- Open Access
- 3 November 2019
- Published by SCI AND TECH UNIVERSAL INC in Scientia Iranica
- Vol. 28 (1) , 265-272
Hot-film/hot-wire anemometer calibration for low velocities using image processing
Calibration of hot-wire and hot-film probes at low velocities is a difficult task because the dynamic pressure at these velocities is very low and may not be measured easily. To overcome this problem, substituent techniques have been presented in the literature that rely on other phenomena and utilize different hardware. This paper describes a simple and low-cost method which proposes to move the anemometer probe in quiescent air (here by means of a swinging arm) and track this motion with a camera. After processing of the images, velocity time history of the probe is found by numerical calculations. Calibration curve is then obtained without any predetermined relationship. Using a medium-speed video camera that is often found in laboratories would avoid the need to a position sensor and a complicated arm on which this sensor is mounted. This technique can be used not only for pendulums but also for other means of moving probes in quiescent medium.
- 3 November 2019
- Published by SCI AND TECH UNIVERSAL INC in Scientia Iranica
- Vol. 28 (1) , 265-272
Open AccessHot-film/hot-wire anemometer calibration for low velocities using image processing
Calibration of hot-wire and hot-film probes at low velocities is a difficult task because the dynamic pressure at these velocities is very low and may not be measured easily. To overcome this problem, substituent techniques have been presented in the literature that rely on other phenomena and utilize different hardware. This paper describes a simple and low-cost method which proposes to move the anemometer probe in quiescent air (here by means of a swinging arm) and track this motion with a camera. After processing of the images, velocity time history of the probe is found by numerical calculations. Calibration curve is then obtained without any predetermined relationship. Using a medium-speed video camera that is often found in laboratories would avoid the need to a position sensor and a complicated arm on which this sensor is mounted. This technique can be used not only for pendulums but also for other means of moving probes in quiescent medium.