YYYuan Yao

Yuan Yao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yuan Yao has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Experimental Study on Variable Operating Characteristics of Two-Stage Absorption Lithium Bromide Refrigeration Chiller

    by Bingbing Chen, Chaohe Fang, Bo Xiong, Zhenneng Lu, Yuan Yao

    Two-stage absorption lithium bromide (Li-Br) refrigeration technology can utilize low-temperature heat sources to achieve refrigeration, thus it holds promising application prospects in the utilization of low-temperature waste heat. However, the performance of two-stage lithium bromide absorption chillers during variable operating conditions is difficult to accurately predict, necessitating further research. Unlike existing simulation-based studies, this paper employs an experimental approach for the first time to investigate the variable-condition performance of a two-stage lithium bromide absorption chiller. A 10 kW two-stage absorption Li-Br chiller was tested under variable operating conditions, including variations in chilled water outlet temperature, cooling water inlet temperature, hot water inlet temperature, and hot water flow rate. The experimental results indicate that each 1 °C increase in the chilled water outlet temperature leads to an additional 0.282 kW in cooling capacity and a 0.0071 increase in coefficient of performance (COP). Similarly, a 1 °C decrease in the cooling water inlet temperature results in a 0.366 kW increase in cooling capacity and a 0.0055 improvement in COP. When the hot water inlet temperature rises by 1 °C, the cooling capacity increases by 0.324 kW, while the COP remains nearly unchanged. Furthermore, a 10% increase in the hot water mass flow rate enhances the cooling capacity by approximately 5% and improves the COP by about 1%.


  • Open Access

    Thermodynamic and Economic Analysis of a High Temperature Cascade Heat Pump System for Steam Generation

    by Zhenneng Lu, Yuan Yao, Guangping Liu, Weibin Ma, Yulie Gong

    A high temperature cascade heat pump (HTCHP) system using low-grade heat from waste water to generate steam for industrial processes is studied from the thermodynamic and economic view. The effects of intermediate temperature, heat source temperature, heat sink temperature, working fluids, and the pinch point temperature difference at the evaporator, condenser, and intermediate heat exchanger on the thermodynamic performance and cost-effectiveness of the HTCHP system are investigated. The PBP varying with the gas price and electricity price is evaluated as well. The results show that optimal intermediate temperatures exist under different operational conditions, not only for the COP, but also for the PBP. A high heat source temperature and low heat sink temperature are conducive to increasing the COP and shortening the PBP. Working fluid pair R1234Ze(E)-R1233zd(Z) shows a promising application in the HTCHP system for its relatively high COP, short PBP, and low GWP. A lower pinch point temperature difference will cause a higher COP and shorter PBP, but a higher SEC. The energy price has a great effect on the economic viability of the system. When the price ratio is lower than 1.81, the PBP is lower than 4.6 years.


  • Open Access

    Drying Characteristics of a Combined Drying System of Low-Pressure Superheated Steam and Heat Pump

    by Yuan Yao, Zhenneng Lu, Yulie Gong, Song Guo, Chupeng Xiao, Wenbo Hu

    The present study aimed at investigating the use of a drying system combining the concept of low-pressure superheated steam drying and heat pump drying for fish. The effects of various drying medium pressures on the temperature field, airflow field, drying time, equipment performance as well as the power consumption of the drying process were investigated and discussed. Four comparative tests with different initial pressures were carried out according to a specified drying process by the combined drying system. The results showed that when the vacuum was high, the temperature field and airflow field in the drying chamber were more uniform. Due to the poor heat transfer performance of the drying medium at high vacuum, the drying time increased with a decrease in initial pressure. It was also found that with the decrease in drying medium pressure, the power consumption of the heat pump and the axial fans was reduced, while the power consumption of the electric heater went up. Overall, the total power consumption is directly proportional to the drying medium pressure.


  • Open Access

    Numerical Analysis and Optimization of Solar-Assited Heat Pump Drying System with Waste Heat Recovery Based on TRNSYS

    by Zhiyuan Xie, Yulie Gong, Cantao Ye, Yuan Yao, Yubin Liu

    In this paper, a new solar-assisted heat pump drying system with waste heat recovery and double water tanks (SCAHP) was established and the system optimized by TRNSYS and variable air volume experiment. The annual cumulative efficiency of the SCAHP (COPac), buffer tank heating efficiency (ηBT) and hot water storage tank heating efficiency (ηST) are all considered as optimization objectives, and this paper discusses the relationship between the three optimization objectives and studies the influence of hot air volume (qDR), area of solar collector (ASC), inclination angle of solar collector (ISC) and volume of heat storage water tank (VST) on system efficiency in the drying process. In order to explore the general rule of system optimization, numerical analysis and optimization were carried out in five typical cities in five climatic regions of China. The results show that the mixed variable air volume mode can increase the drying rate with less energy loss, and shorten the drying period by 28.6–33.3%. When the system surface body ratio (SBR) in Nanjing is between 3.1 and 4.1, the COPac, ηBT, and ηST can reach the maximum value simultaneously. It is estimated that the cost can be recovered in 5 years when the system configuration parameters are optimized.