NFNiora J. Fabian

Niora J. Fabian

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Niora J. Fabian has a total of 81 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Bioinspired soft enteroscopic robot for intestinal locomotion, steering, and intervention

    by Binbin Ying, Ahmad Mujtaba Jebran, Sahab Babaee, Karen Jiang, Brenda D. Fernandez Martinez, Haniyah Shareef, Mohammed Talha Faiz, Andrew Pettinari, Kailyn Schmidt, Niora Fabian, et al.

    Diagnosing and treating small intestinal disorders such as bleeding, inflammatory bowel disease, and tumors present challenges because of limited access to this anatomical compartment. We present BIOSENTER, a bioinspired soft enteroscopic robot for deep procedures in the small intestine that addresses locomotion, steering, and intervention constraints of existing soft robotic systems. BIOSENTER features a hollow cylinder architecture comprising a linearly deformable soft pneumatic actuator as the body, two radially expandable soft pneumatic actuators wrapped with kirigami sleeves as the head and tail, a central hollow channel for accessory endoscopic tools, and a control box for navigation. Inspired by snake locomotion, the robotic body incorporates a fiber-reinforced actuator with four embedded inflatable chambers, enabling steering and axial expansion. The dynamic kirigami sleeves generate an anchoring force of ∼1.5 newtons on intestinal mucosa while requiring substantially less radial expansion than the corresponding nonkirigami configuration. A reinforced central channel supports tool passage for diagnostic and therapeutic interventions. The control box enables locomotion and steering at autonomous speeds of ∼100 millimeters per minute in vitro and ∼43 millimeters per minute in tissue-covered tubing. BIOSENTER successfully navigated the collapsed, tortuous small intestine for 2 meters in 11 minutes, with gentle forward pushing forces of 2.2 to 6.4 newtons in pig studies. In vivo pig studies demonstrated technical feasibility of tissue biopsy, localized fluid delivery as a model for future drug administration, and real-time visualization of the deep intestine, without macroscopic overdistention or visible tissue damage under the tested conditions.

  • An ingestible capsule for luminance-based diagnosis of mesenteric ischemia

    by J. Chen, A. Alexiev, A. Sergnese, N. Fabian, A. Pettinari, Y. Cai, V. Perepelook, K. Schmidt, A. Hayward, A. Guevara, et al.

    Acute mesenteric ischemia (AMI) results from insufficient blood flow to the intestines, leading to tissue necrosis with high morbidity and mortality. Diagnosis is often delayed because of nonspecific symptoms that mimic common gastrointestinal conditions. Current diagnostic methods, such as computed tomography and mesenteric angiography, are complex, costly, and invasive, highlighting the need for a rapid, accessible, and minimally invasive alternative. Here, we present FIREFLI (finding ischemia via reflectance of light), a bioinspired, ingestible capsule designed for luminance-based diagnosis of AMI. Upon ingestion, the device activates in the small intestine’s pH environment, emitting pulses from three radially spaced white light-emitting diodes and measuring reflected light across 10 wavelengths. FIREFLI then computes a tissue luminance biomarker, which outperforms color-change biomarkers because of superior intrasubject consistency. The diagnosis is processed onboard and wirelessly transmitted to an external mobile device. In vivo studies in swine ( n = 9) demonstrated a diagnostic accuracy of 90%, with a sensitivity of 98% and specificity of 85%. By providing a noninvasive, real-time diagnostic solution, FIREFLI has the potential to facilitate earlier detection and treatment of AMI, ultimately improving patient outcomes.


  • Top Cited Papers

    An electroadhesive hydrogel interface prolongs porcine gastrointestinal mucosal theranostics

    by Binbin Ying, Kewang Nan, Qing Zhu, Tom Khuu, Hana Ro, Sophia Qin, Shubing Wang, Karen Jiang, Yonglin Chen, Guangyu Bao, et al.

    Establishing a robust and intimate mucosal interface that allows medical devices to remain within lumen-confined organs for extended periods has valuable applications, particularly for gastrointestinal theranostics. Here, we report the development of an electroadhesive hydrogel interface for robust and prolonged mucosal retention after electrical activation (e-GLUE). The e-GLUE device is composed of cationic polymers interpenetrated within a tough hydrogel matrix. An e-GLUE electrode design eliminated the need for invasive submucosal placement of ground electrodes for electrical stimulation during endoscopic delivery. With an electrical stimulation treatment of about 1 minute, the cationic polymers diffuse and interact with polyanionic proteins that have a relatively slow cellular turnover rate in the deep mucosal tissue. This mucosal adhesion mechanism increased the adhesion energy of hydrogels on the mucosa by up to 30-fold and enabled in vivo gastric retention of e-GLUE devices in a pig stomach for up to 30 days. The adhesion strength was modulated by polycationic chain length, electrical stimulation time, gel thickness, cross-linking density, voltage amplitude, polycation concentration, and perimeter-to-area ratio of the electrode assembly. In porcine studies, e-GLUE demonstrated rapid mucosal adhesion in the presence of luminal fluid and mucus exposure. In proof-of-concept studies, we demonstrated e-GLUE applications for mucosal hemostasis, sustained local delivery of therapeutics, and intimate biosensing in the gastrointestinal tract, which is an ongoing clinical challenge for commercially available alternatives, such as endoclips and mucoadhesive. The e-GLUE platform could enable theranostic applications across a range of digestive diseases, including recurrent gastrointestinal bleeding and inflammatory bowel disease.


  • Infertility and periocular swelling in a female zebra finch (Taeniopygia guttata)

    by Yao Lee, Emily G. Franklin, Magalie Boucher, Nathan M. Pate, Niora J. Fabian

    "Infertility and periocular swelling in a female zebra finch (Taeniopygia guttata)" published on 19 Apr 2024 by American Veterinary Medical Association.


  • A Comparison of LED with Fluorescent Lighting on the Stress, Behavior, and Reproductive Success of Laboratory Zebra Finches (Taeniopygia guttata)

    by Alanna G Backx, April Wu, Alyx Tanner, Niora J Fabian

    There are limited evidence-based husbandry recommendations for laboratory zebra finches (Taeniopygia guttata), including appropriate light sources. Light-emitting diode (LED) technology has been shown to improve circadian regulation and reduce stress in some laboratory animal species, such as mice and rats, when compared with cool-white fluorescent (CWF) lighting, but the effects of LED lighting on zebra finches have not been published. We compared the effects of broad-spectrum, blue-enriched (6,500 Kelvin) CWF and flicker-free LED lighting on the behavior, stress, and reproductive outcomes of indoor-housed zebra finches. Using breeding pairs housed in cubicles illuminated with either CWF or LED lighting, we compared the reproductive output as determined by clutch size, hatching rate, and hatchling survival rate. We also compared the behavior of group-housed adult males, first housed under CWF followed by LED lighting, using video recordings and an ethogram. Fecal samples were collected from these males at the end of each recording period, and basal fecal corticosterone metabolite (FCM) levels were compared. A FCM assay for adult male zebra finches was validated for efficacy and accuracy using a capture-restraint acute stress response and parallelism analysis, respectively. The breeding pairs had no significant difference in the clutch size or percent hatching rate, but percent hatchling survival improved under LED with an increased proportion achieving 100% survival. There was no significant difference in FCM between the lighting treatments. However, the activity budgets of the birds were altered, with a reduction in flighted movement and an increase in enrichment manipulation under LED. Overall, these results support the use of blue-enriched, broad-spectrum flicker-free LED as a safe alternative to CWF lighting for breeding and nonbreeding indoor-housed zebra finches.


  • Open Access

    A vibrating ingestible bioelectronic stimulator modulates gastric stretch receptors for illusory satiety

    by Shriya S Srinivasan, Amro Alshareef, Alexandria Hwang, Ceara Byrne, Johannes Kuosmanen, Keiko Ishida, Joshua Jenkins, Sabrina Liu, Wiam Abdalla Mohammed Madani, Alison M Hayward, et al.

    Effective therapies for obesity require invasive surgical and endoscopic interventions or high patient adherence, making it challenging for patients with obesity to effectively manage their disease. Gastric mechanoreceptors sense distension of the stomach and perform volume-dependent vagal signaling to initiate the gastric phase and influence satiety. In this study, we developed a new luminal stimulation modality to specifically activate these gastric stretch receptors to elicit a vagal afferent response commensurate with mechanical distension. We designed the Vibrating Ingestible BioElectronic Stimulator (VIBES) pill, an ingestible device that performs luminal vibratory stimulation to activate mechanoreceptors and stroke mucosal receptors, which induces serotonin release and yields a hormonal metabolic response commensurate with a fed state. We evaluated VIBES across 108 meals in swine which consistently led to diminished food intake (~40%,P< 0.0001) and minimized the weight gain rate (P< 0.05) as compared to untreated controls. Application of mechanoreceptor biology could transform our capacity to help patients suffering from nutritional disorders.


  • Open Access

    Evaluation and comparison of pharmacokinetic profiles and safety of two extended-release buprenorphine formulations in common marmosets (Callithrix jacchus)

    by Niora J. Fabian, Anthony J. Mannion, Morgan Jamiel, David. J. Anderson, Joseph E. Rower, Christopher A. Reilly, William Menegas, Sureshkumar Muthupalani, Christina Ta, James G. Fox, et al.

    While sustained-release buprenorphine (BSR) is used as a long-lasting opioid analgesic in common marmosets (Callithrix jacchus), there are no published studies on pharmaceutical-grade extended-release buprenorphine options such as Ethiqa XR (EXR) for this species. However, BSR is a compounded product and has been reported to cause injection site reactions in multiple species, including marmosets. Additionally, now with the availability of EXR, a pharmaceutical-grade veterinary product, the use of BSR in laboratory animals is not compliant with the Guide for the Care and Use of Laboratory Animals (Guide) unless scientifically justified and approved by the IACUC. We compared pharmacokinetic and safety profiles of BSR (0.15 mg/kg) and EXR (0.1–0.2 mg/kg) administered subcutaneously to adult marmosets. Blood was collected by venipuncture of the saphenous vein at multiple time points (0.25–72 h) and analyzed by liquid chromatography-tandem mass spectrometry (LC–MS/MS). EXR between 0.1 and 0.2 mg/kg resulted in a dose-dependent increase in Cmax (1.43–2.51 ng/mL) and were not statistically different from BSR (1.82 ng/mL). Tmax, lambdaz, and t1/2 were not statistically different between formulations. Mean plasma buprenorphine concentrations for BSR and EXR exceeded the therapeutic threshold (0.1 ng/mL) within 0.25 h and lasted for > 72 h. Mild sedation, but neither respiratory depression nor ataxia, was observed for both formulations. BSR injection sites had significantly higher histopathological scores compared to EXR. Video recordings for monitoring drug-induced behavioral changes showed increased animal activity levels after BSR and EXR versus saline controls. Norbuprenorphine, a buprenorphine metabolite associated with respiratory depression, was detected in the plasma after BSR and EXR administration as well as by in vitro liver microsome assays. In conclusion, we recommend using EXR over BSR as a long-lasting buprenorphine analgesic in marmosets because EXR is a pharmaceutical-grade formulation that is compliant with FDA guidelines and the Guide as well as exhibits comparable PK and safety profiles as BSR.


  • Pharmacokinetics of Single-Dose Intramuscular and Subcutaneous Injections of Buprenorphine in Common Marmosets (Callithrix jacchus)

    by Niora J Fabian, David E Moody, Olga Averin, Wenfang B Fang, Morgan Jamiel, James G Fox, Monika A Burns, Jennifer L Haupt

    Although buprenorphine is the most frequently used opioid analgesic in common marmosets (Callithrix jacchus), there is limited information in the literature supporting current dosing regimens used for this species. The purpose of this study was to determine the pharmacokinetic profiles of single-dose buprenorphine HCl administered intramuscularly (IM) at 0.01 mg/kg in 6 adult marmosets (1.8 to 12.8 y old; 2 males, 4 females) and subcutaneously (SQ) at 0.01 mg/kg in 6 adult marmo- sets (2.3-4.4 y old; 3 males, 3 females) by mass spectrometry. Blood was collected at multiple time points from 0.25 to 24 h from unsedated animals following a hybrid sparse-serial sampling design. The maximal observed plasma concentration of buprenorphine (Cmax) administered IM (2.57 ± 0.95 ng/mL) was significantly higher than administered SQ (1.47 ± 0.61 ng/mL). However, the time to Cmax(Tmax) was not statistically different between routes (17.4 ± 6 min for IM and 19.8 ± 7.8 min for SQ). The time of the last quantifiable concentration of buprenorphine was 5 ± 1.67 h for IM compared with 6.33 ± 1.51 h for SQ, which was not statistically different. The mean buprenorphine plasma concentration-time curves were used to propose a dosing frequency of 4 to 6 h for buprenorphine at 0.01 mg/kg IM or SQ based on a theoretical therapeutic plasma concentration threshold of 0.1 ng/mL. Based on the mean pharmacokinetic parameters and plasma-concentration time curves, both IM and SQ routes of buprenorphine at this dose provide a rapid increase in the plasma concentration of buprenorphine above the therapeutic threshold, and may be more effective for acute rather than long-lasting analgesia. Further studies are needed to examine repeated dosing regimens and the efficacy of buprenorphine in common marmosets.


  • Cutaneous leiomyosarcoma with visceral metastases in a White Carneau pigeon and literature review

    by Niora J. Fabian, Michael Y. Esmail, Lauren Richey, Sureshkumar Muthupalani, Jennifer L. Haupt, Joanna Joy, Sebastian E. Carrasco

    Cutaneous leiomyosarcomas are malignant mesenchymal tumors of smooth muscle origin and are reported occasionally in avian species. A 14-y-old male laboratory White Carneau pigeon (Columba livia) was presented for surgical excision of a cervical soft tissue mass. Ultrasonography with color flow Doppler imaging revealed multiple cavitations of mixed echogenicity within the mass and vascularization. Histologically, the dermis and subcutis were expanded by a densely cellular multinodular mass comprised of fusiform cells forming haphazardly arranged broad streams and short interwoven bundles, often surrounding blood vessels and variably sized cavitations. Neoplastic cells were strongly immunopositive for desmin and α–smooth muscle actin, and negative for pancytokeratin, S100, and von Willebrand factor. Based on histopathology and IHC findings, the cutaneous mass was diagnosed as leiomyosarcoma (LMS). The pigeon died 312 d post-operatively. Postmortem examination revealed masses infiltrating the left and right pulmonary airways and one hepatic nodule, but no regrowth at the surgical site. Histologic and IHC evaluation of the pulmonary and hepatic masses were consistent with LMS, representing metastatic foci from the primary cutaneous LMS. Our case highlights the malignant behavior and histomorphologic features of cutaneous LMS in an avian species.