GXGuangyao Xu

Guangyao Xu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Guangyao Xu has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Film Superposition Characteristics With Laidback Fan-Shaped Holes Under the Influence of Internal Crossflow

    by Liu Haoyang, Du Qiang, Xu Qingzong, Xu Jiawei, Xu Guangyao, Li Hongye, Wang Pengfei

    In the serpentine passage of actual rotor blades, the coolant at the inlet of the film hole has an internal crossflow. The internal crossflow significantly influences the film cooling effectiveness of multi-row film holes. This paper presents a numerical investigation of the superposition characteristics of multiple rows of laidback fan-shaped holes under the influence of internal crossflow. The numerical simulations utilize the RANS method considering the effects of blowing ratio, crossflow velocity ratio, arrangement patterns, and row-to-row spacing of the internal crossflow on the superposition characteristics of film holes. The results indicate that film cooling effectiveness exhibits a distinctly asymmetric distribution under crossflow conditions. At different blowing ratios, there exists an optimal crossflow velocity ratio, at which the laterally averaged film cooling effectiveness is maximized. The crossflow-to-jet velocity ratio (VRi) is utilized to comprehensively evaluate the impact of blowing ratios and crossflow velocity ratios, and the range of high area-averaged film cooling effectiveness is accurately captured. Regarding the study of arrangement patterns and row-to-row spacings, it has been found that under identical coolant mass flowrates, the staggered arrangement is better than the inline arrangement in both laterally averaged film cooling effectiveness and cooling uniformity. Meanwhile, reducing the row-to-row spacing leads to an improvement in laterally averaged film cooling effectiveness. Finally, an assessment of the Sellers model's applicability under crossflow conditions revealed that it demonstrates good applicability in cases of staggered arrangement with lower blowing ratios.


  • Investigation of the Discharge Coefficient for Laidback Fan-Shaped Holes on Turbine Blades Under Internal Crossflow Condition

    by Haoyang Liu, Qiang Du, Qingzong Xu, Hongye Li, Guangyao Xu

    The discharge coefficient of laidback fan-shaped holes on turbine blades under internal crossflow conditions is investigated using experimental and numerical simulation methods. The study is conducted on a linear cascade, with single rows of film holes set on both the pressure and suction surfaces of the test blade, coolant supplied by an internal crossflow channel. The internal crossflow Reynolds number ranged from 39,100 to 78,200, and the pressure ratio ranged from 1 to 1.5. This research considered the effects of internal crossflow Reynolds numbers and hole length-to-diameter ratio on the discharge coefficient of laidback fan-shaped holes. The findings are as follows: internal crossflow increases the inlet loss of film holes and flow separation within the holes, leading to a significant reduction in the discharge coefficient of film holes. Meanwhile, film holes on the pressure surface of the blade exhibit greater sensitivity to crossflow. Under different hole length-to-diameter ratio conditions, the length of the cylindrical section is the primary factor affecting the discharge coefficient, and the magnitude of the discharge coefficient depends on the extent of flow separation within the cylindrical section. The sensitivity of the discharge coefficient to variations in the cylindrical section length decreases once the cylindrical section length exceeds 2.8D for the pressure surface and 2.0D for the suction surface, where the inlet separation region reattaches to the wall. Under plenum conditions, there are significant differences in the discharge coefficients of film holes between the suction surface and pressure surface, especially at pressure ratios below 1.05.


  • Effect of the Key Geometry and Flow Parameters on Discharge Coefficient of Laidback Fan-Shaped Hole Under Coolant Crossflow Condition

    by Liu Haoyang, Du Qiang, Xu Qingzong, Xu Guangyao, Li Hongye, Chen Dawei, Liu Song, Wang Siyi

    A laidback fan-shaped hole is commonly used due to its superior lateral film coverage. Its discharge coefficient is significantly influenced by internal crossflow owing to its complex geometrical structure. In this paper, the authors numerically investigate the flow mechanisms of the laidback fan-shaped hole under the influence of internal crossflow. The numerical simulations utilize the validated SST k–ω turbulence model, with the Reynolds number of internal crossflow ranging from 20,000 to 160,000 and the ratio of pressure ranging from 1 to 1.6. The results show that the different orientations of internal crossflow cause varying degrees of in-hole separation that led to a discrepancy in the discharge coefficient. The larger the Reynolds number of the crossflow is, the more drastic the change in the discharge coefficient. Furthermore, a comparison between the results obtained with and without internal crossflow has shown that the length of the cylindrical section is the primary factor determining the discharge coefficient of the laidback fan-shaped hole. The magnitude of the discharge coefficient depended on the extent of flow separation within the cylindrical section. Additionally, the numerical simulations obtained the discharge coefficient under a high internal crossflow Reynolds number of internal crossflow and a wall with a constant thickness and compared it with the predictions of a low-dimensional model of the discharge coefficient (based on our previous experimental data). The discrepancy between the results is within 10%, thus verifying the scalability of the low-dimensional model.


  • Conjugate Heat Transfer Characteristics of a Film-Cooled Turbine Blade Leading Edge With Staggered-Oblique Impinging Jets

    by Li Hongye, Du Qiang, Xu Qingzong, Xu Guangyao, Liu Haoyang, Chen Dawei

    The turbine blade leading edge is subjected to harsh conditions due to high heat loads and unfavorable compact structures. To improve the cooling performance, a novel impingement scheme is proposed to be used in a film-cooled turbine blade leading edge. Different from a normal impingement scheme, the novel scheme consists of two rows of staggered impinging jets at oblique angles of ±35 deg, and is thus named as the staggered-oblique impingement scheme. A conjugated numerical investigation is carried out to illustrate the underlying mechanisms of the cooling performance. Three typical jet Reynolds numbers, 6000, 12,000, and 18,000, are studied using the validated SST k–ω turbulence model. Numerical results show a flow separation within the staggered-oblique impinging jets, which causes the discharge coefficient for the novel impingement scheme lower than that for the normal impingement scheme. Results also reveal a phenomenon difference that two symmetric vortices are induced by each normal impinging jet, while only one vortex appears on the acute angle side along with each staggered-oblique impinging jet. The flow fields of the staggered-oblique impingement scheme create a more uniform heat transfer distribution and a maximum of 23.7% higher area-averaged Nusselt number than the normal impingement scheme. The area-averaged overall cooling effectiveness for the staggered-oblique impingement scheme is higher than the normal impingement scheme by a maximum of 4.8%. The uniformity and the enhancement of the overall cooling effectiveness arise from the wall jet being fully developed and affecting a larger area of the target wall. The adiabatic cooling effectiveness is similar for both impingement schemes. This indicates that the improvement in overall cooling effectiveness for the staggered-oblique impingement scheme mainly arises from internal heat transfer.


  • Sensitivity of Laidback Fan-Shaped Hole Discharge Coefficient Under Internal Coolant Crossflow Conditions

    by Liu Haoyang, Du Qiang, Xu Qingzong, Xu Guangyao, Li Hongye, Chen Dawei

    An experimental study was performed on the discharge coefficients of laidback fan-shaped holes under different internal coolant crossflow orientations. The influence of the geometric and flow parameters on the discharge coefficient was investigated under flat plate conditions, where the pressure ratio ranged from 1 to 1.6. The results show that the film hole discharge coefficient is more sensitive to variations in the coolant crossflow under small pressure ratios. In comparison, the discharge coefficient is much less sensitive to the change of coolant crossflow under high pressure. Meanwhile, the length of the cylindrical section varied over the range of 1D–4D, and the length of the expansion section varied from 2D to 6D, where D represents the diameter of the film hole. The results show that the discharge coefficient is much more sensitive to the length of the cylindrical section than to the length of the expansion section. To quantify the sensitivity of the internal crossflow effects on the discharge coefficient, a low-ordered reduced model is proposed for the discharge coefficient of laidback fan-shaped holes. Both the geometric and flow parameters are considered in the model and give prediction errors within 5%.


  • Numerical Study of Crossflow Effects on Discharge Coefficient of the Converging Slot Hole

    by Qingzong Xu, Guangyao Xu, Qiang Du, Dawei Chen, Haoyang Liu, Hongye Li

    Converging slot hole is considered as a high-performance film hole with excellent film cooling effectiveness and relatively low aerodynamic loss. Previous studies on converging slot holes mainly focused on the film cooling effectiveness and heat transfer characteristics, whereas the discharge coefficient has not been fully understood, especially when the compressible effects cannot be ignored. This study numerically evaluated the effects of crossflows and compressibility on the discharge coefficient of the converging slot hole by comparing it with fan-shaped holes, and developed a promising prediction method for the discharge coefficient with both external and internal crossflows. The results show that the crossflow orientations and the compressible external/internal crossflows significantly influenced the discharge coefficients and flow fields of the converging slot hole. The trend of the discharge coefficient of the converging slot hole is obviously different from that of the fan-shaped holes because of the different flow conditions inside the holes. Moreover, the empirical correlations for the discharge coefficient of the converging slot hole based on the no-crossflow data were consistent with the numerical results, validating the numerical methods used in this study.


  • Detached Eddy Simulation of the Unsteady Flow and Film Cooling Characteristics of an Endwall With an Interrupted Slot

    by Qiang Du, Guangyao Xu, Qingzong Xu, Pei Wang

    The flows close to a high-pressure turbine endwall are highly three-dimensional and unsteady. These flows increase the aerodynamic loss and augment the heat transfer. In this paper, the unsteady flows and film cooling characteristics of an endwall were studied by using the Detached eddy simulation (DES). First, the unsteady flows and film cooling characteristics of a slot on a flat plate were studied at three different coolant mass flow ratios. A comparison of the experimental and numerical results showed that the DES offered an improved ability to capture the distribution of film cooling effectiveness. The aerothermal characteristics of the interrupted slot on a vane endwall were then studied. By analyzing the unsteady flow as well as the mixing process, it was found that the shedding vortices produced by the step lip played a dominant role in the film cooling distribution and the formation of the horseshoe vortex. The coupling of the shedding vortices with the horseshoe vortex had an important influence on the film effectiveness on the endwall. Finally, the effect of the axial distance between the interrupted slot and the vane leading edge on the formation of the horseshoe vortex was further studied. The instantaneous vorticity contours showed that varying the axial position of the interrupted slot affected the development of the horseshoe vortex. As the axial distance increased, the horseshoe vortex disappeared periodically and then reappeared. As the axial distance decreased, the horseshoe vortex retained a steady pattern upstream of the vane leading edge.


  • Experimental Investigation of Film Cooling Performance on Blade Endwall With Diffusion Slot Holes and Stator–Rotor Purge Flow

    by Zhiqiang Yu, Jianjun Liu, Chen Li, Baitao An, Guangyao Xu

    This paper focuses on the influences of the discrete-hole shape and layout on the blade endwall film cooling effectiveness. The effect of upstream purge slot injection on the film cooling performance of the discrete hole was also investigated. The diffusion slot hole was first applied to the blade endwall. As a comparison, the cooling performance of the fan-shaped hole was also measured. Totally, six discrete-hole cooling configurations (two hole shapes × three layouts) were investigated. Experiments were performed in a seven-blade linear cascade with the exit Reynolds number of 2.64 × 105. The average blowing ratios (BR) of the discrete holes changed from 0.5 to 2.5, and the coolant mass flow ratio of the purge slot (MFR) was fixed at MFR = 1.5%. The distributions of the cooling effectiveness on the blade endwall were measured by the pressure-sensitive paint technique. Results indicate that the diffusion slot hole significantly increases the film cooling effectiveness on the blade endwall compared to the fan-shaped hole, especially at a high blowing ratio. The maximum relative increment of the cooling effectiveness is over 40%. The layout with the discrete holes arranged lining up with the tangent direction of the blade profile offset curves exhibits a comparable film cooling effectiveness with the layout with the discrete holes arranged according to the cross-flow direction. The film cooling effectiveness on the pressure surface corner is remarkably enhanced by deflecting the hole orientation angle toward the pressure surface. The combination of purge slot and diffusion slot holes supplies a full-coverage film cooling for the entire blade endwall at MFR = 1.5% and BR = 2.5. In addition, the slot injection leads to a non-negligible influence on the cooling performance of the discrete holes near the separation line.