YAYoshiharu Akiyama

Yoshiharu Akiyama

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yoshiharu Akiyama has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Unsymmetric Voltage of Conducted Noise Measurement System Without Grounding by Estimation of Ground Capacitance

    by Naruto Arai, Yohei Toriumi, Ken Okamoto, Jun Kato, Yoshiharu Akiyama, Ken Sasaki

    Conducted noise originating from power supply equipment disrupts telecommunication networks, causing problems such as telecommunication interruptions and reduction in the speed of communication. Measurement of noise in data transmission lines at a repair site may require additional work to secure the electrical ground level for the measurement, because the data lines are differential pairs and the ground level is not always accessible. A method to estimate the capacitance between the measurement equipment and the ground was developed to allow measurement without access to the ground, i.e., in floating conditions. The method uses an oscillator and multiple electrodes to measure the capacitive coupling with the ground under the floor. A ground-capacitance-estimating device was fabricated and tested. Its accuracy was further improved by incorporating a linear function to express the relationship between the output of the device and the known ground capacitance in the calibration setting. This calibration procedure and the measurement procedure at the repair site are described. The noise voltage was calculated from the estimated ground capacitance and the voltage reading of the floating measurement equipment. The estimated ground capacitance was in the order of several tens of pF. The error of the corrected noise voltage was within 1.6 dB.


  • Method of Measuring Conducted Noise Voltage with a Floating Measurement System to Ground

    by Naruto Arai, Ken Okamoto, Jun Kato, Yoshiharu Akiyama

    This paper describes a method of measuring the unsymmetric voltage of conducted noise using a floating measurement system. Here, floating means that there is no physical connection to the reference ground. The method works by correcting the measured voltage to the desired unsymmetric voltage using the capacitance between the measurement instrument and the reference ground plane acting as the return path of the con ducted electromagnetic noise. The existing capacitance measurement instrument needs a probe in contact with the ground, so it is difficult to use for on site measurement of stray capacitance to ground at troubleshooting sites where the ground plane is not exposed or no ground connection point is available. The a uthors have developed a method of measuring stray capacitance to ground that does no t require physical connection of the probe to the ground plane. The developed method can be used to estimate the ca pacitance between the measurement instrument and ground plane even if the distance and relative permittivity of the space are unknown. And a method is proposed for correcting the voltage measured with the floating measurement system to obtain the unsymmetric voltage of the noise by using the measured capacitance to ground. In the experiment, the unsymmetric voltage of a sinusoidal wave transmitting on a co axial cable w as measured with a floating oscilloscope in a shield room and the measured voltage was co rrected to within 2 dB of expected voltage by using the capacitance measured with the developed method. In addition, the voltage of a rectangular wave measured with the floating oscilloscope, which displays sag caused by the stray capacitance to ground, was corrected to a rectangular wave without sag. This means that the phase of the unsymmetric voltage can also be corrected by the measured stray capacitance. From these results, the effectiveness of the proposed methods is shown.