Bo Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Bo Zhang has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Haibo Yang
Department of Ultrasound, West China Second Hospital, Sichuan University, Chengdu, China
3 shared publicationsHouqing Pang
Department of Ultrasound, West China Second Hospital, Sichuan University, Chengdu, China
3 shared publications- Hong Luo
Department of Ultrasound, West China Second University Hospital, Sichuan University, Chengdu, China
2 shared publications - Hong Luo
Key Laboratory of Birth Defects and Related Diseases of Women and Children of MOE, West China Second University Hospital, Sichuan University, Chengdu, Sichuan, China
2 shared publications - Bo Zhang
Department of Ultrasound, West China Second Hospital, Sichuan University/ Key Laboratory of Obstetrics & Gynecology, Pediatric Diseases, and Birth Defects of the Ministry of Education
1 shared publication Fenglin Jia
Key Laboratory of Birth Defects and Related Diseases of Women and Children (Sichuan University) Ministry of Education Chengdu China
1 shared publication
Latest Publications
- Open Access
- 1 June 2026
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 16 (6) , 483
Spatiotemporal characterization of placental hypoxia and microvascular dysfunction in a preeclampsia rat model using photoacoustic and contrast-enhanced ultrasound
Background: Placental ischemia and hypoxia are central drivers of preeclampsia (PE) pathogenesis. However, conventional Doppler ultrasound primarily evaluates uterine and umbilical arterial resistance to indirectly infer placental impedance, lacking the sensitivity to directly quantify intraplacental tissue oxygenation and microvascular perfusion dynamics. This study aimed to explore the feasibility of using a multimodal imaging approach, combining photoacoustic imaging (PAI) and contrast-enhanced ultrasound (CEUS), to characterize the longitudinal spatiotemporal features of placental dysfunction in an Nω-nitro-L-arginine methyl ester (L-NAME)-induced PE rat model. Methods: Pregnant Sprague-Dawley rats were randomly assigned to control and PE groups (n=10 per group). PE was induced via daily L-NAME administration (250 mg/kg/day) from gestational day (GD) 7 to GD18. Longitudinal multimodal imaging was performed on the same cohort of rats at GD14, GD16, and GD18. PAI was utilized to quantitatively map hemoglobin oxygen saturation (sO2), with sub-regional analysis performed to evaluate the oxygenation gradient between the labyrinth and basal zones. CEUS was employed to quantify microvascular hemodynamic parameters. Imaging biomarkers were validated against histological markers of hypoxia (HIF-1α) and vascular density (CD31). Results: PAI revealed a physiological oxygenation gradient (labyrinth > basal) in normal placentas. In the PE group, a progressive hypoxic shift was observed, with mean sO2 levels significantly reduced starting from GD14 compared to controls (52.2%±5.4% vs. 59.4%±5.1%, Pvs. 61.8%±5.4%, Pvs. 10,956.1±4,166.1 arbitrary units (a.u.), P2 was negatively correlated with HIF-1α (r=−0.73, P2) perfusion (WiAUC) metrics yielded an area under the curve (AUC) of 0.89 for early disease prediction at GD14, and 0.93 for discriminating PE placentas at GD18. Conclusions: This preliminary study demonstrates the feasibility of longitudinal multimodal imaging to characterize placental dysfunction. Specifically, PAI effectively captured the progressive hypoxic shift, complementing the CEUS-derived “volume-velocity dissociation”, which suggests that microvascular rarefaction precedes flow velocity alterations. By integrating metabolic and perfusion metrics, this platform holds promise as a quantitative tool for preclinical monitoring and therapeutic evaluation.
- 1 June 2026
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 16 (6) , 483
Open AccessSpatiotemporal characterization of placental hypoxia and microvascular dysfunction in a preeclampsia rat model using photoacoustic and contrast-enhanced ultrasound
Background: Placental ischemia and hypoxia are central drivers of preeclampsia (PE) pathogenesis. However, conventional Doppler ultrasound primarily evaluates uterine and umbilical arterial resistance to indirectly infer placental impedance, lacking the sensitivity to directly quantify intraplacental tissue oxygenation and microvascular perfusion dynamics. This study aimed to explore the feasibility of using a multimodal imaging approach, combining photoacoustic imaging (PAI) and contrast-enhanced ultrasound (CEUS), to characterize the longitudinal spatiotemporal features of placental dysfunction in an Nω-nitro-L-arginine methyl ester (L-NAME)-induced PE rat model. Methods: Pregnant Sprague-Dawley rats were randomly assigned to control and PE groups (n=10 per group). PE was induced via daily L-NAME administration (250 mg/kg/day) from gestational day (GD) 7 to GD18. Longitudinal multimodal imaging was performed on the same cohort of rats at GD14, GD16, and GD18. PAI was utilized to quantitatively map hemoglobin oxygen saturation (sO2), with sub-regional analysis performed to evaluate the oxygenation gradient between the labyrinth and basal zones. CEUS was employed to quantify microvascular hemodynamic parameters. Imaging biomarkers were validated against histological markers of hypoxia (HIF-1α) and vascular density (CD31). Results: PAI revealed a physiological oxygenation gradient (labyrinth > basal) in normal placentas. In the PE group, a progressive hypoxic shift was observed, with mean sO2 levels significantly reduced starting from GD14 compared to controls (52.2%±5.4% vs. 59.4%±5.1%, Pvs. 61.8%±5.4%, Pvs. 10,956.1±4,166.1 arbitrary units (a.u.), P2 was negatively correlated with HIF-1α (r=−0.73, P2) perfusion (WiAUC) metrics yielded an area under the curve (AUC) of 0.89 for early disease prediction at GD14, and 0.93 for discriminating PE placentas at GD18. Conclusions: This preliminary study demonstrates the feasibility of longitudinal multimodal imaging to characterize placental dysfunction. Specifically, PAI effectively captured the progressive hypoxic shift, complementing the CEUS-derived “volume-velocity dissociation”, which suggests that microvascular rarefaction precedes flow velocity alterations. By integrating metabolic and perfusion metrics, this platform holds promise as a quantitative tool for preclinical monitoring and therapeutic evaluation.
- Open Access
- 1 May 2026
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 16 (5) , 430
Hemodynamic evolution of umbilical-portal stenosis mimicking portal vein agenesis: description of a prenatal case
Hemodynamic evolution of umbilical-portal stenosis mimicking portal vein agenesis: description of a prenatal case
- 1 May 2026
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 16 (5) , 430
Open AccessHemodynamic evolution of umbilical-portal stenosis mimicking portal vein agenesis: description of a prenatal case
Hemodynamic evolution of umbilical-portal stenosis mimicking portal vein agenesis: description of a prenatal case
- Open Access
- 7 March 2026
- Published by Elsevier in Asian Journal of Surgery
- Vol. 49 (6) , 3345-3346
The value of combined ultrasound and MRI for the diagnosis of massive subchorionic hematoma with succenturiate placenta
- 7 March 2026
- Published by Elsevier in Asian Journal of Surgery
- Vol. 49 (6) , 3345-3346
Open AccessThe value of combined ultrasound and MRI for the diagnosis of massive subchorionic hematoma with succenturiate placenta
- Open Access
- 2 February 2026
- Published by Elsevier in Asian Journal of Surgery
- Vol. 49 (4) , 2003-2004
Dual-modal photoacoustic/ultrasound imaging in biomedical applications: Bibliometric trends and clinical frontiers
- 2 February 2026
- Published by Elsevier in Asian Journal of Surgery
- Vol. 49 (4) , 2003-2004
Open AccessDual-modal photoacoustic/ultrasound imaging in biomedical applications: Bibliometric trends and clinical frontiers
- 5 December 2025
- Published by Wiley in Prenatal Diagnosis
- Vol. 46 (1) , 138-144
Fetal Phenotype and Diagnosis of Treacher Collins Syndrome Due to a Novel POLR1D Variant
Key Points: What is already known about this topic? What does this study add?
- 5 December 2025
- Published by Wiley in Prenatal Diagnosis
- Vol. 46 (1) , 138-144
Fetal Phenotype and Diagnosis of Treacher Collins Syndrome Due to a Novel POLR1D Variant
Key Points: What is already known about this topic? What does this study add?
- Open Access
- 1 September 2024
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 14 (9) , 6386-6396
Evaluation of prenatal and postnatal ultrasonography for the diagnosis of fetal double bubble sign
Congenital duodenal obstruction (CDO) is commonly detected antenatally through the presence of the “double bubble” sign on prenatal ultrasound, denoting dilatation of the stomach and duodenum. Subsequent postnatal ultrasonography plays a pivotal role in determining the causes of obstruction, thereby informing surgical strategies and neonatal management. The aim of this study was to investigate the diagnostic accuracy of postnatal ultrasonography in comparison to that of prenatal ultrasound and surgical findings in a cohort of 43 patients with fetal double bubble sign. A total of 43 patients, comprising 24 males and 19 females, who exhibited double bubble sign on prenatal ultrasound were subjected to postnatal ultrasound assessment at a tertiary care facility during the 2018–2023 period. The accuracy of both pre-and postnatal ultrasonography in the identification and diagnosis of CDO, as well as its underlying causes, was compared to that of the established gold standard of surgical findings. The accuracy rates for prenatal and postnatal ultrasonic diagnosis of CDO were 97.7% (42/43) and 100% (42/42), respectively. In terms of etiological diagnosis, prenatal and postnatal ultrasound correctly identified the causes of obstruction in 45.2% (19/42) and 81.0% (34/42) of cases, respectively, as confirmed by surgical intervention. The presence of the prenatal double bubble sign serves as a highly reliable indicator for CDO. Additionally, postnatal ultrasonography proved to be a valuable tool in refining the diagnosis and determining the underlying causes of obstruction in neonates.
- 1 September 2024
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 14 (9) , 6386-6396
Open AccessEvaluation of prenatal and postnatal ultrasonography for the diagnosis of fetal double bubble sign
Congenital duodenal obstruction (CDO) is commonly detected antenatally through the presence of the “double bubble” sign on prenatal ultrasound, denoting dilatation of the stomach and duodenum. Subsequent postnatal ultrasonography plays a pivotal role in determining the causes of obstruction, thereby informing surgical strategies and neonatal management. The aim of this study was to investigate the diagnostic accuracy of postnatal ultrasonography in comparison to that of prenatal ultrasound and surgical findings in a cohort of 43 patients with fetal double bubble sign. A total of 43 patients, comprising 24 males and 19 females, who exhibited double bubble sign on prenatal ultrasound were subjected to postnatal ultrasound assessment at a tertiary care facility during the 2018–2023 period. The accuracy of both pre-and postnatal ultrasonography in the identification and diagnosis of CDO, as well as its underlying causes, was compared to that of the established gold standard of surgical findings. The accuracy rates for prenatal and postnatal ultrasonic diagnosis of CDO were 97.7% (42/43) and 100% (42/42), respectively. In terms of etiological diagnosis, prenatal and postnatal ultrasound correctly identified the causes of obstruction in 45.2% (19/42) and 81.0% (34/42) of cases, respectively, as confirmed by surgical intervention. The presence of the prenatal double bubble sign serves as a highly reliable indicator for CDO. Additionally, postnatal ultrasonography proved to be a valuable tool in refining the diagnosis and determining the underlying causes of obstruction in neonates.
- 15 August 2024
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 52 (9) , 1440-1441
Ileal venous malformation in a pediatric patient
A 16-month-old girl presented with ileal venous malformation. Ultrasound facilitated a preoperative diagnosis, leading to a successful surgical resection. The study emphasizes the critical role of identifying sonographic features like intestinal wall thickening, a serpiginous mass with sluggish blood sinuses, and rich vascular flow for accurate diagnosis and timely treatment. image
- 15 August 2024
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 52 (9) , 1440-1441
Ileal venous malformation in a pediatric patient
A 16-month-old girl presented with ileal venous malformation. Ultrasound facilitated a preoperative diagnosis, leading to a successful surgical resection. The study emphasizes the critical role of identifying sonographic features like intestinal wall thickening, a serpiginous mass with sluggish blood sinuses, and rich vascular flow for accurate diagnosis and timely treatment. image
- Open Access
- 29 January 2021
- Published by Wolters Kluwer Health in Medicine
- Vol. 100 (4) , e24427
Automatic quality assessment for 2D fetal sonographic standard plane based on multitask learning
The quality control of fetal sonographic (FS) images is essential for the correct biometric measurements and fetal anomaly diagnosis. However, quality control requires professional sonographers to perform and is often labor-intensive. To solve this problem, we propose an automatic image quality assessment scheme based on multitask learning to assist in FS image quality control. An essential criterion for FS image quality control is that all the essential anatomical structures in the section should appear full and remarkable with a clear boundary. Therefore, our scheme aims to identify those essential anatomical structures to judge whether an FS image is the standard image, which is achieved by 3 convolutional neural networks. The Feature Extraction Network aims to extract deep level features of FS images. Based on the extracted features, the Class Prediction Network determines whether the structure meets the standard and Region Proposal Network identifies its position. The scheme has been applied to 3 types of fetal sections, which are the head, abdominal, and heart. The experimental results show that our method can make a quality assessment of an FS image within less a second. Also, our method achieves competitive performance in both the segmentation and diagnosis compared with state-of-the-art methods.
- 29 January 2021
- Published by Wolters Kluwer Health in Medicine
- Vol. 100 (4) , e24427
Open AccessAutomatic quality assessment for 2D fetal sonographic standard plane based on multitask learning
The quality control of fetal sonographic (FS) images is essential for the correct biometric measurements and fetal anomaly diagnosis. However, quality control requires professional sonographers to perform and is often labor-intensive. To solve this problem, we propose an automatic image quality assessment scheme based on multitask learning to assist in FS image quality control. An essential criterion for FS image quality control is that all the essential anatomical structures in the section should appear full and remarkable with a clear boundary. Therefore, our scheme aims to identify those essential anatomical structures to judge whether an FS image is the standard image, which is achieved by 3 convolutional neural networks. The Feature Extraction Network aims to extract deep level features of FS images. Based on the extracted features, the Class Prediction Network determines whether the structure meets the standard and Region Proposal Network identifies its position. The scheme has been applied to 3 types of fetal sections, which are the head, abdominal, and heart. The experimental results show that our method can make a quality assessment of an FS image within less a second. Also, our method achieves competitive performance in both the segmentation and diagnosis compared with state-of-the-art methods.