Kwi-Bok Lee
Kwi-Bok Lee has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Cheol-Min Lee
Department of Environmental & Chemical Engineering, Seokyeong University, Seoul 02713, Republic of Korea
1 shared publication - Hui Been Lim
Department of Nano & Biological Engineering, SeoKyeong University, Seoul 02713, Korea
1 shared publication - Hye-Won Lee
Institute of Risk Assessment, Seokyeong University
1 shared publication - Jeong-In Jeon
Department of Chemical and Environmental Engineering, Seokyeong University, Seoul 02713, Republic of Korea
1 shared publication - So-Yeon Park
Research Center of the Records Preservation, National Library of Korea, Seoul 06579, Korea
1 shared publication
Latest Publications
- Open Access
- 10 February 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (4) , 1715
A Preliminary Research Study for Distribution Characteristics and Sources of Indoor Air Pollutants in the Valuable Archive of the National Library of Korea
Important records can be damaged directly and indirectly. Their restoration, if possible, is difficult as it is very time-consuming and costly. Although measures have been taken to permanently preserve records, most studies focus on preventing short-term damage from physical or biological factors and not on preventive measures against chemical damage from long-term polluted air exposure. This study investigated the types, concentrations, and distribution characteristics of hazardous chemicals present in the valuable archive of the National Library of Korea (NLK) and identified the sources of these pollutants. Mean SO2, NOX, CO, CO2, and total volatile organic compound (TVOC) concentrations were 1.49 ± 0.44 ppb, 30.52 ± 19.70 ppb, 0.75 ± 0.21 ppm, 368.91 ± 32.23 ppm, and 320.03 ± 44.20 µg/m3, respectively, meeting the Ministry of the Interior and Safety (MOIS) of Korea standards. Toluene (66.43 ± 10.69 µg/m3) and acetaldehyde (157.23 ± 6.43 µg/m3) were present at the highest concentrations, respectively. Two principal components were extracted via a principal component analysis; the primary component (66%) was closely related to outdoor pollution sources and the secondary component (33%) to indoor sources. Results contribute to establishing air quality standards and management measures for preservation of this archive.
- 10 February 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (4) , 1715
Open AccessA Preliminary Research Study for Distribution Characteristics and Sources of Indoor Air Pollutants in the Valuable Archive of the National Library of Korea
Important records can be damaged directly and indirectly. Their restoration, if possible, is difficult as it is very time-consuming and costly. Although measures have been taken to permanently preserve records, most studies focus on preventing short-term damage from physical or biological factors and not on preventive measures against chemical damage from long-term polluted air exposure. This study investigated the types, concentrations, and distribution characteristics of hazardous chemicals present in the valuable archive of the National Library of Korea (NLK) and identified the sources of these pollutants. Mean SO2, NOX, CO, CO2, and total volatile organic compound (TVOC) concentrations were 1.49 ± 0.44 ppb, 30.52 ± 19.70 ppb, 0.75 ± 0.21 ppm, 368.91 ± 32.23 ppm, and 320.03 ± 44.20 µg/m3, respectively, meeting the Ministry of the Interior and Safety (MOIS) of Korea standards. Toluene (66.43 ± 10.69 µg/m3) and acetaldehyde (157.23 ± 6.43 µg/m3) were present at the highest concentrations, respectively. Two principal components were extracted via a principal component analysis; the primary component (66%) was closely related to outdoor pollution sources and the secondary component (33%) to indoor sources. Results contribute to establishing air quality standards and management measures for preservation of this archive.