James D Pollard
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
James D Pollard has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Elsayed Z. Soliman
Epidemiological Cardiology Research Center, Department of Cardiovascular Medicine, Wake Forest University School of Medicine, Winston-Salem, NC
1 shared publication Joseph Maher
University of Mississippi Medical Center , 2500 N State St, Jackson, MS 39216, USA
1 shared publicationJoão A C Lima
Cardiovascular Division, Department of Medicine 733 N Broadway, Baltimore, MD 21205, USA
1 shared publication- Katherine Lutz
Oregon Health & Science University
1 shared publication Kazi T Haq
Department of Medicine, Knight Cardiovascular Institute, Oregon Health & Science University , 3181 SW Sam Jackson Park Rd, UHN62, Portland, OR 97239, USA
1 shared publicationKevin A Paternostro
Department of Medicine, Knight Cardiovascular Institute, Oregon Health & Science University , 3181 SW Sam Jackson Park Rd, UHN62, Portland, OR 97239, USA
1 shared publication
Latest Publications
- Open Access
- 20 January 2021
- Published by Oxford University Press (OUP) in European Heart Journal - Digital Health
- Vol. 2 (1) , 137-151
Electrocardiogram machine learning for detection of cardiovascular disease in African Americans: the Jackson Heart Study
Almost half of African American (AA) men and women have cardiovascular disease (CVD). Detection of prevalent CVD in community settings would facilitate secondary prevention of CVD. We sought to develop a tool for automated CVD detection. Participants from the Jackson Heart Study (JHS) with analysable electrocardiograms (ECGs) (n = 3679; age, 62 ± 12 years; 36% men) were included. Vectorcardiographic (VCG) metrics QRS, T, and spatial ventricular gradient vectors’ magnitude and direction, and traditional ECG metrics were measured on 12-lead ECG. Random forests, convolutional neural network (CNN), lasso, adaptive lasso, plugin lasso, elastic net, ridge, and logistic regression models were developed in 80% and validated in 20% samples. We compared models with demographic, clinical, and VCG input (43 predictors) and those after the addition of ECG metrics (695 predictors). Prevalent CVD was diagnosed in 411 out of 3679 participants (11.2%). Machine learning models detected CVD with the area under the receiver operator curve (ROC AUC) 0.69–0.74. There was no difference in CVD detection accuracy between models with VCG and VCG + ECG input. Models with VCG input were better calibrated than models with ECG input. Plugin-based lasso model consisting of only two predictors (age and peak QRS-T angle) detected CVD with AUC 0.687 [95% confidence interval (CI) 0.625–0.749], which was similar (P = 0.394) to the CNN (0.660; 95% CI 0.597–0.722) and better (P < 0.0001) than random forests (0.512; 95% CI 0.493–0.530). Simple model (age and QRS-T angle) can be used for prevalent CVD detection in limited-resources community settings, which opens an avenue for secondary prevention of CVD in underserved communities.
- 20 January 2021
- Published by Oxford University Press (OUP) in European Heart Journal - Digital Health
- Vol. 2 (1) , 137-151
Open AccessElectrocardiogram machine learning for detection of cardiovascular disease in African Americans: the Jackson Heart Study
Almost half of African American (AA) men and women have cardiovascular disease (CVD). Detection of prevalent CVD in community settings would facilitate secondary prevention of CVD. We sought to develop a tool for automated CVD detection. Participants from the Jackson Heart Study (JHS) with analysable electrocardiograms (ECGs) (n = 3679; age, 62 ± 12 years; 36% men) were included. Vectorcardiographic (VCG) metrics QRS, T, and spatial ventricular gradient vectors’ magnitude and direction, and traditional ECG metrics were measured on 12-lead ECG. Random forests, convolutional neural network (CNN), lasso, adaptive lasso, plugin lasso, elastic net, ridge, and logistic regression models were developed in 80% and validated in 20% samples. We compared models with demographic, clinical, and VCG input (43 predictors) and those after the addition of ECG metrics (695 predictors). Prevalent CVD was diagnosed in 411 out of 3679 participants (11.2%). Machine learning models detected CVD with the area under the receiver operator curve (ROC AUC) 0.69–0.74. There was no difference in CVD detection accuracy between models with VCG and VCG + ECG input. Models with VCG input were better calibrated than models with ECG input. Plugin-based lasso model consisting of only two predictors (age and peak QRS-T angle) detected CVD with AUC 0.687 [95% confidence interval (CI) 0.625–0.749], which was similar (P = 0.394) to the CNN (0.660; 95% CI 0.597–0.722) and better (P < 0.0001) than random forests (0.512; 95% CI 0.493–0.530). Simple model (age and QRS-T angle) can be used for prevalent CVD detection in limited-resources community settings, which opens an avenue for secondary prevention of CVD in underserved communities.