Veronika Cherkashyna
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Veronika Cherkashyna has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Halyna Omelianenko
Національний технічний університет «Харківський політехнічний інститут», Україна
5 shared publications - Антон Олександрович Макаров
Національний технічний університет «Харківський політехнічний інститут
3 shared publications - Igor Volodymyrovych Barbashov2 shared publications
- Oleg Yakovenko2 shared publications
- Vladislav Kuchanskyy
Department of Power-Supply Systems Optimization, Institute of Electrodynamics, National Academy of Sciences of Ukraine, Beresteyskiy, 56, 03680 Kyiv, Ukraine
2 shared publications - Vladyslav Mykolayovych Baklytskyi2 shared publications
Latest Publications
- Open Access
- 29 May 2026
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University "KhPI". Series: Energy: Reliability and Energy Efficiency
- No. 1(12),p. 151-158
Research on energy efficiency issues of the electric power transmission system
The article presents a comprehensive analysis of the technical and economic characteristics of cable and overhead power transmission lines, which makes it possible to make a well-reasoned decision regarding the selection of an object for improving the energy efficiency of the electric power transmission system. The voltage class of the power transmission system is substantiated, and it is determined that this system operates at a nominal voltage of 110 kV. In accordance with the voltage class of the power transmission system, the current-carrying parts for overhead and cable power transmission lines are selected, and the cross-sections of the conductors and cable cores are checked according to the permissible current load. Based on the results of the selection and verification, it was found that both the overhead and cable lines have the same cross-section of the current-carrying part – 240 mm². The parameters of the equivalent circuits for the overhead and cable transmission lines are determined. The process of electric power transmission through overhead and cable lines is analyzed, and it is established that the voltage deviation is within ±5 %, which confirms compliance with power quality indicators and the equivalence of the analyzed options. Taking this into account, an economic analysis was carried out to justify the optimal line option by calculating the cost component of the integral effect of total discounted costs. It was found that the cable line is 79 % more expensive than the overhead line. Therefore, a SWOT analysis was conducted to justify the choice of the most appropriate transmission line. According to the results, the project with a cable line proved to be more attractive than the project with an overhead line. Thus, based on the presented research results, it follows that in order to improve the energy efficiency of a 110 kV electric power transmission system with a length of 20 km, it is advisable to use a cable power transmission line.
- 29 May 2026
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University "KhPI". Series: Energy: Reliability and Energy Efficiency
- No. 1(12),p. 151-158
Open AccessResearch on energy efficiency issues of the electric power transmission system
The article presents a comprehensive analysis of the technical and economic characteristics of cable and overhead power transmission lines, which makes it possible to make a well-reasoned decision regarding the selection of an object for improving the energy efficiency of the electric power transmission system. The voltage class of the power transmission system is substantiated, and it is determined that this system operates at a nominal voltage of 110 kV. In accordance with the voltage class of the power transmission system, the current-carrying parts for overhead and cable power transmission lines are selected, and the cross-sections of the conductors and cable cores are checked according to the permissible current load. Based on the results of the selection and verification, it was found that both the overhead and cable lines have the same cross-section of the current-carrying part – 240 mm². The parameters of the equivalent circuits for the overhead and cable transmission lines are determined. The process of electric power transmission through overhead and cable lines is analyzed, and it is established that the voltage deviation is within ±5 %, which confirms compliance with power quality indicators and the equivalence of the analyzed options. Taking this into account, an economic analysis was carried out to justify the optimal line option by calculating the cost component of the integral effect of total discounted costs. It was found that the cable line is 79 % more expensive than the overhead line. Therefore, a SWOT analysis was conducted to justify the choice of the most appropriate transmission line. According to the results, the project with a cable line proved to be more attractive than the project with an overhead line. Thus, based on the presented research results, it follows that in order to improve the energy efficiency of a 110 kV electric power transmission system with a length of 20 km, it is advisable to use a cable power transmission line.
- 28 March 2026
- Published by Vidnovluvana energetika in Vidnovluvana energetika
- No. 1(84)
RESEARCH INTO RELIABILITY ISSUES OF AN ELECTRIC POWER TRANSMISSION SYSTEM WITH A PHOTOVOLTAIC POWER PLAN
The article provides a study of the reliability of the electric power transmission system with a photovoltaic power plant through a comprehensive analysis of the technical and economic characteristics of cable and overhead power lines. The choice of voltage class for the system under study, which has a radial electrical grid topology with an installed photovoltaic plant at the receiving substation, is justified. In accordance with the selected voltage class, the conductive part of the overhead and cable lines is determined, and the cross-sections of the wires and cable cores are checked for acceptable current load conditions. Based on the verifi-cation results, the current-carrying part of the overhead transmission line was selected using an ACSR 240/32 mm² conductor, while the cable line was designed with an APvEgP-110 1×240/95 mm² cable. The parameters of the overhead and cable transmission lines were determined, and a comparative analysis of the technological process of electric power transmission in a radial grid was performed using the PowerFac-tory software package, in particular with respect to voltage deviations in both transmission system vari-ants. It was shown that, in terms of technical performance indicators, the overhead and cable lines are equivalent. Taking this into account, an economic analysis was carried out to substantiate the optimal line option by calculating the cost component of the integral effect of total discounted costs. The results of this analysis indicate that the cable line is 59.4% more expensive than the overhead line. To further justify the feasibility of selecting the line type, a SWOT analysis was conducted, which demonstrated that the project incorporating a cable line is more attractive than the project based on an overhead line. The proposed com-prehensive analysis of the techno-economic characteristics of overhead and cable lines enables a well-grounded decision to be made regarding the selection of the appropriate facility to enhance the reliability of an electric power transmission system with a photovoltaic power plant, provided that the technical parame-ters of the electrical grid are equivalent.
- 28 March 2026
- Published by Vidnovluvana energetika in Vidnovluvana energetika
- No. 1(84)
RESEARCH INTO RELIABILITY ISSUES OF AN ELECTRIC POWER TRANSMISSION SYSTEM WITH A PHOTOVOLTAIC POWER PLAN
The article provides a study of the reliability of the electric power transmission system with a photovoltaic power plant through a comprehensive analysis of the technical and economic characteristics of cable and overhead power lines. The choice of voltage class for the system under study, which has a radial electrical grid topology with an installed photovoltaic plant at the receiving substation, is justified. In accordance with the selected voltage class, the conductive part of the overhead and cable lines is determined, and the cross-sections of the wires and cable cores are checked for acceptable current load conditions. Based on the verifi-cation results, the current-carrying part of the overhead transmission line was selected using an ACSR 240/32 mm² conductor, while the cable line was designed with an APvEgP-110 1×240/95 mm² cable. The parameters of the overhead and cable transmission lines were determined, and a comparative analysis of the technological process of electric power transmission in a radial grid was performed using the PowerFac-tory software package, in particular with respect to voltage deviations in both transmission system vari-ants. It was shown that, in terms of technical performance indicators, the overhead and cable lines are equivalent. Taking this into account, an economic analysis was carried out to substantiate the optimal line option by calculating the cost component of the integral effect of total discounted costs. The results of this analysis indicate that the cable line is 59.4% more expensive than the overhead line. To further justify the feasibility of selecting the line type, a SWOT analysis was conducted, which demonstrated that the project incorporating a cable line is more attractive than the project based on an overhead line. The proposed com-prehensive analysis of the techno-economic characteristics of overhead and cable lines enables a well-grounded decision to be made regarding the selection of the appropriate facility to enhance the reliability of an electric power transmission system with a photovoltaic power plant, provided that the technical parame-ters of the electrical grid are equivalent.
- 1 January 2026
- Published by State Scientific Institution - Ukrainian Institute of Scientific and Technical Expertise and Info
Models and methods for optimizing the structure and operating modes of main electric networks: monograph
The monograph has developed and substantiated a set of models and methods for optimizing the structure and operating modes of main electric networks by structuring overhead lines and using controlled compensation tools, which allows on a single basis to compare and justify options for lines of different voltage classes in order to minimize discounted costs and select optimal technical parameters of electric network objects. The results of the research presented in the monograph can be used in the development of schemes and programs for the development of a unified power system; feasibility study of investment projects; updating the regulatory and methodological framework for the design and operation of main power grids; planning the development and reconstruction of main power grids in Ukraine.
- 1 January 2026
- Published by State Scientific Institution - Ukrainian Institute of Scientific and Technical Expertise and Info
Models and methods for optimizing the structure and operating modes of main electric networks: monograph
The monograph has developed and substantiated a set of models and methods for optimizing the structure and operating modes of main electric networks by structuring overhead lines and using controlled compensation tools, which allows on a single basis to compare and justify options for lines of different voltage classes in order to minimize discounted costs and select optimal technical parameters of electric network objects. The results of the research presented in the monograph can be used in the development of schemes and programs for the development of a unified power system; feasibility study of investment projects; updating the regulatory and methodological framework for the design and operation of main power grids; planning the development and reconstruction of main power grids in Ukraine.
- Open Access
- 9 July 2025
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University "KhPI". Series: Energy: Reliability and Energy Efficiency
- No. 1(10),p. 101-106
The appropriateness of using electrical energy storage systems to increase the reliability of Ukrainian electrical networks
A study was conducted that allowed to substantiate the expedient use of electric energy storage devices in the electrical networks of Ukraine. The relevance of this study is due to the introduction of renewable energy sources into the electrical networks of Ukraine, which contributes to the need for the accumulation of electric energy. To find ways to solve this problem, an analysis of flywheel, superconducting inductive electric energy storage devices, high-capacity batteries, and supercapacitors was performed. Their operating features, advantages, and disadvantages were considered. From the analysis of the advantages, disadvantages, and features of the operation of electrical energy storage devices, it follows that it is advisable to determine the optimal scope of application for each of them and identify their correspondence to the problem existing in electrical networks. The analysis made it possible to do this and justify the optimal scope of application of each type of storage device, as well as to identify their compliance with the problem of power supply in electrical networks. To increase the energy efficiency of the network by optimizing the processes of electricity production and consumption, schemes for connecting electrical energy storage devices have been developed, namely a scheme that takes into account the reliability categories of consumers and a scheme that takes into account the presence of renewable energy sources in the networks. The proposed schemes for connecting electrical energy storage devices allow for the elimination of large backup generating power plants while maintaining the operational reliability of the network. To apply an appropriate type of electric energy storage device when solving a particular problem, a structural model of the correspondence of the type of storage device to the problem being solved has been formed. The application of the formed structural model will allow improving the quality of electric energy, the operational reliability of the network and the energy efficiency of the electric system as a whole.
- 9 July 2025
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University "KhPI". Series: Energy: Reliability and Energy Efficiency
- No. 1(10),p. 101-106
Open AccessThe appropriateness of using electrical energy storage systems to increase the reliability of Ukrainian electrical networks
A study was conducted that allowed to substantiate the expedient use of electric energy storage devices in the electrical networks of Ukraine. The relevance of this study is due to the introduction of renewable energy sources into the electrical networks of Ukraine, which contributes to the need for the accumulation of electric energy. To find ways to solve this problem, an analysis of flywheel, superconducting inductive electric energy storage devices, high-capacity batteries, and supercapacitors was performed. Their operating features, advantages, and disadvantages were considered. From the analysis of the advantages, disadvantages, and features of the operation of electrical energy storage devices, it follows that it is advisable to determine the optimal scope of application for each of them and identify their correspondence to the problem existing in electrical networks. The analysis made it possible to do this and justify the optimal scope of application of each type of storage device, as well as to identify their compliance with the problem of power supply in electrical networks. To increase the energy efficiency of the network by optimizing the processes of electricity production and consumption, schemes for connecting electrical energy storage devices have been developed, namely a scheme that takes into account the reliability categories of consumers and a scheme that takes into account the presence of renewable energy sources in the networks. The proposed schemes for connecting electrical energy storage devices allow for the elimination of large backup generating power plants while maintaining the operational reliability of the network. To apply an appropriate type of electric energy storage device when solving a particular problem, a structural model of the correspondence of the type of storage device to the problem being solved has been formed. The application of the formed structural model will allow improving the quality of electric energy, the operational reliability of the network and the energy efficiency of the electric system as a whole.
- 25 March 2025
- Published by DP Express-obyava
Studying of issues of quality assessment of electricity supply services
- 25 March 2025
- Published by DP Express-obyava
Studying of issues of quality assessment of electricity supply services
- Open Access
- 30 August 2024
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Praci Institutu elektrodinamiki Nacionalanoi akademii nauk Ukraini
- Vol. 2024 (68) , 63-70
ANALYSIS OF SERVICE QUALITY INDICATORS SUPPLY OF ELECTRIC ENERGY
The object of the study is the processes in distribution electric networks and their influence on technical and economic characteristics aimed at achieving the main indicators of reliability, which is characterized by the continuity of electricity supply, namely, indicators of the quality of services: the index of the average duration of long interruptions and the index of the average frequency of long interruptions ( SAIDI, SAIFI), as well as compliance with the guaranteed quality standards of electric energy supply services, which are established by the Resolution of the NCRECP. The problem to be solved is a set of factors aimed at reducing the index of the average duration of long interruptions and the index of the average frequency of long interruptions (SAIDI, SAIFI), taking into account and applying effective measures of stimulating tariff formation (Rab - tariff) aimed at providing quality services to consumers of electric energy in accordance with the guaranteed standards established by the Resolution of the NCRECP. The analysis of the main indicators of the quality of SAIDI and SAIFI services for the period from 01.01.2022 to 03.31.2022 was carried out on the example of the operator of the distribution system JSC "Kharkivoblenergo". The impact of natural and unnatural factors on the formation of these indicators is analyzed, taking into account force majeure circumstances and military aggression on the territory of the Kharkiv region. The changes in the quality indicators of SAIDI and SAIFI services and their compliance with the normative values established by the NCRECP were analyzed. The conducted analysis of SAIDI and SAIFI service quality indicators allows us to state that achieving the target values of electricity supply continuity indicators is a fundamental factor for improving the quality of electricity supply services to consumers. The provision of the necessary guaranteed quality standards for the supply of electric energy to consumers is substantiated taking into account the stimulating tariff formation (Rab - tariff). It is shown that the introduction and development of stimulating tariff formation lays a reliable foundation for a strong and competitive Ukraine on the territory of the European Union and introduces dynamic development for a strong and independent Ukrainian economy. Ref. 19, figure, table.
- 30 August 2024
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Praci Institutu elektrodinamiki Nacionalanoi akademii nauk Ukraini
- Vol. 2024 (68) , 63-70
Open AccessANALYSIS OF SERVICE QUALITY INDICATORS SUPPLY OF ELECTRIC ENERGY
The object of the study is the processes in distribution electric networks and their influence on technical and economic characteristics aimed at achieving the main indicators of reliability, which is characterized by the continuity of electricity supply, namely, indicators of the quality of services: the index of the average duration of long interruptions and the index of the average frequency of long interruptions ( SAIDI, SAIFI), as well as compliance with the guaranteed quality standards of electric energy supply services, which are established by the Resolution of the NCRECP. The problem to be solved is a set of factors aimed at reducing the index of the average duration of long interruptions and the index of the average frequency of long interruptions (SAIDI, SAIFI), taking into account and applying effective measures of stimulating tariff formation (Rab - tariff) aimed at providing quality services to consumers of electric energy in accordance with the guaranteed standards established by the Resolution of the NCRECP. The analysis of the main indicators of the quality of SAIDI and SAIFI services for the period from 01.01.2022 to 03.31.2022 was carried out on the example of the operator of the distribution system JSC "Kharkivoblenergo". The impact of natural and unnatural factors on the formation of these indicators is analyzed, taking into account force majeure circumstances and military aggression on the territory of the Kharkiv region. The changes in the quality indicators of SAIDI and SAIFI services and their compliance with the normative values established by the NCRECP were analyzed. The conducted analysis of SAIDI and SAIFI service quality indicators allows us to state that achieving the target values of electricity supply continuity indicators is a fundamental factor for improving the quality of electricity supply services to consumers. The provision of the necessary guaranteed quality standards for the supply of electric energy to consumers is substantiated taking into account the stimulating tariff formation (Rab - tariff). It is shown that the introduction and development of stimulating tariff formation lays a reliable foundation for a strong and competitive Ukraine on the territory of the European Union and introduces dynamic development for a strong and independent Ukrainian economy. Ref. 19, figure, table.
- Open Access
- 5 July 2024
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University "KhPI". Series: Energy: Reliability and Energy Efficiency
- No. 1 (8),p. 8-12
Research on improving the efficiency of electricity transmission
A study of ways to modernize the current-carrying part of overhead lines to improve the efficiency of electricity transmission through the use of innovative types of wires was conducted. The technical and economic characteristics of AC, ACCR, and AERO-Z wires were analyzed. The results of the analysis revealed that further improvement of the design of AC wires should be based on new progressive developments that would meet such technical requirements as reliability, survivability and durability; corrosion resistance; high adhesion ability; resistance to vibration during operation under the influence of adverse climatic factors; resistance to environmental temperature effects. As an innovative solution to this issue, high-temperature (ACCR) and specially designed (AERO-Z) wires have been developed in foreign countries. A comparative analysis of the types of wires used in Ukrainian power grids with innovative types of wires used in power grids of foreign countries was performed. The results of the comparison of AC, ACCR, and AERO-Z wires show that the factor that limits the scope of application of ACCR wire, even for spans with extremely high requirements for power transmission characteristics, is its extremely high cost. This is because the technical characteristics of this wire are better than those of AC wire and it has a relatively low cost compared to ACCR wire, and its special design is adapted to adverse climatic conditions that affect the characteristics of electricity transmission.
- 5 July 2024
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University "KhPI". Series: Energy: Reliability and Energy Efficiency
- No. 1 (8),p. 8-12
Open AccessResearch on improving the efficiency of electricity transmission
A study of ways to modernize the current-carrying part of overhead lines to improve the efficiency of electricity transmission through the use of innovative types of wires was conducted. The technical and economic characteristics of AC, ACCR, and AERO-Z wires were analyzed. The results of the analysis revealed that further improvement of the design of AC wires should be based on new progressive developments that would meet such technical requirements as reliability, survivability and durability; corrosion resistance; high adhesion ability; resistance to vibration during operation under the influence of adverse climatic factors; resistance to environmental temperature effects. As an innovative solution to this issue, high-temperature (ACCR) and specially designed (AERO-Z) wires have been developed in foreign countries. A comparative analysis of the types of wires used in Ukrainian power grids with innovative types of wires used in power grids of foreign countries was performed. The results of the comparison of AC, ACCR, and AERO-Z wires show that the factor that limits the scope of application of ACCR wire, even for spans with extremely high requirements for power transmission characteristics, is its extremely high cost. This is because the technical characteristics of this wire are better than those of AC wire and it has a relatively low cost compared to ACCR wire, and its special design is adapted to adverse climatic conditions that affect the characteristics of electricity transmission.
- Open Access
- 9 July 2023
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University "KhPI". Series: Energy: Reliability and Energy Efficiency
- No. 1 (6),p. 45-50
Study of foreign experience in dealing with ice and frost deposits on the wires of overhead power lines
The means and technologies for predicting and preventing frost and ice deposits on the wires of overhead power lines in the power grids of foreign countries are presented. The focus is on such systems as Meteo, dynamic thermal rating, online monitoring of China Southern Power Grid, Variable resistance cable de-icing system and mobile ice melting units. The advantages and disadvantages of these systems are analyzed and it is found that such approaches require energy consumption and are relevant only for the relevant region of the power grid, depending on weather conditions and the distance of electricity transmission. The mechanical, electromechanical, electrothermal, and physicochemical methods of predicting frost and ice deposits on the wires of overhead power lines are considered. It was found that the consideration of dynamic processes is essential and effective in the study of power grids in extreme weather conditions, and the data on frost and ice deposits on overhead line wires are characterized by high dimensionality, nonlinearity, multimodality, and heterogeneity, which makes it impossible to create an accurate forecasting model using traditional methods of evaluation and decision-making. The method of time series analysis and the method of Ensemble Empirical Mode Decomposition are proposed to solve this problem. The basis of these methods is to maximize the use of inherent regularities represented by frequency and time characteristics for effective data analysis and to create the basis for subsequent models and improve their forecasting accuracy. On the basis of the research, the author proposes ways to adapt and integrate the experience of foreign countries into the power grids of Ukraine. The necessity of creating integrated information systems for monitoring meteorological parameters and operating modes of power grids using specialized forecasting models and IT systems is substantiated, which will automate the process of assessing the current state of overhead power lines based on meteorological data in order to timely prevent emergencies in power grids provoked by frost and ice deposits.
- 9 July 2023
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University "KhPI". Series: Energy: Reliability and Energy Efficiency
- No. 1 (6),p. 45-50
Open AccessStudy of foreign experience in dealing with ice and frost deposits on the wires of overhead power lines
The means and technologies for predicting and preventing frost and ice deposits on the wires of overhead power lines in the power grids of foreign countries are presented. The focus is on such systems as Meteo, dynamic thermal rating, online monitoring of China Southern Power Grid, Variable resistance cable de-icing system and mobile ice melting units. The advantages and disadvantages of these systems are analyzed and it is found that such approaches require energy consumption and are relevant only for the relevant region of the power grid, depending on weather conditions and the distance of electricity transmission. The mechanical, electromechanical, electrothermal, and physicochemical methods of predicting frost and ice deposits on the wires of overhead power lines are considered. It was found that the consideration of dynamic processes is essential and effective in the study of power grids in extreme weather conditions, and the data on frost and ice deposits on overhead line wires are characterized by high dimensionality, nonlinearity, multimodality, and heterogeneity, which makes it impossible to create an accurate forecasting model using traditional methods of evaluation and decision-making. The method of time series analysis and the method of Ensemble Empirical Mode Decomposition are proposed to solve this problem. The basis of these methods is to maximize the use of inherent regularities represented by frequency and time characteristics for effective data analysis and to create the basis for subsequent models and improve their forecasting accuracy. On the basis of the research, the author proposes ways to adapt and integrate the experience of foreign countries into the power grids of Ukraine. The necessity of creating integrated information systems for monitoring meteorological parameters and operating modes of power grids using specialized forecasting models and IT systems is substantiated, which will automate the process of assessing the current state of overhead power lines based on meteorological data in order to timely prevent emergencies in power grids provoked by frost and ice deposits.
- Open Access
- 9 July 2023
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University "KhPI". Series: Energy: Reliability and Energy Efficiency
- No. 1 (6),p. 113-118
ANALYSIS OF DIFFERENTIAL RELAY PROTECTION ALGORITHMS AND THEIR MODELLING IN MATLAB
The paper is devoted to identifying the prospects for software implementation of differential relay protection. The purpose of this study was to analyse the algorithms of the devices' operation, which allowed to create a mathematical model in the MATLAB software environment with the prospect of integration in the form of a single regional relay protection server into the unified energy system of Ukraine. It has been established that virtual models have both advantages and disadvantages compared to digital-analog devices. Their positive feature is that, due to the block principle of construction, it is possible to easily change not only the parameters but also the configuration of the primary network. The disadvantage is that the configuration of virtual protections differs from the configuration of their prototypes - real relays and terminals. The article evaluates the existing, widely used methodology and considers the actual algorithms of two-stage differential relay protection. It is established that differential protection has two stages: 1 - fast-acting differential current cut-off; 2 - sensitive differential current protection with inhibition from through current and recovery from magnetisation current surges. A simplified diagram of a fragment of the electrical system and differential relay protection of a transformer are developed and presented in MATLAB. The algorithms are considered in detail, and it is established that with their help and with the help of the considered principles of differential protection in the Simulink package, the logic of the model is implemented similarly to the logic of microprocessor-based transformer protection "RS-83DT2" of RZA Systems LLC, SPAD 346 C of ABB. Based on the modelling results, the oscillograms of primary currents of normal mode and emergency modes with external and internal short circuits are obtained. The conclusions establish the prospects of using this model and algorithms for the development of a software solution for the relay protection server and for future integration into the integrated power system.
- 9 July 2023
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University "KhPI". Series: Energy: Reliability and Energy Efficiency
- No. 1 (6),p. 113-118
Open AccessANALYSIS OF DIFFERENTIAL RELAY PROTECTION ALGORITHMS AND THEIR MODELLING IN MATLAB
The paper is devoted to identifying the prospects for software implementation of differential relay protection. The purpose of this study was to analyse the algorithms of the devices' operation, which allowed to create a mathematical model in the MATLAB software environment with the prospect of integration in the form of a single regional relay protection server into the unified energy system of Ukraine. It has been established that virtual models have both advantages and disadvantages compared to digital-analog devices. Their positive feature is that, due to the block principle of construction, it is possible to easily change not only the parameters but also the configuration of the primary network. The disadvantage is that the configuration of virtual protections differs from the configuration of their prototypes - real relays and terminals. The article evaluates the existing, widely used methodology and considers the actual algorithms of two-stage differential relay protection. It is established that differential protection has two stages: 1 - fast-acting differential current cut-off; 2 - sensitive differential current protection with inhibition from through current and recovery from magnetisation current surges. A simplified diagram of a fragment of the electrical system and differential relay protection of a transformer are developed and presented in MATLAB. The algorithms are considered in detail, and it is established that with their help and with the help of the considered principles of differential protection in the Simulink package, the logic of the model is implemented similarly to the logic of microprocessor-based transformer protection "RS-83DT2" of RZA Systems LLC, SPAD 346 C of ABB. Based on the modelling results, the oscillograms of primary currents of normal mode and emergency modes with external and internal short circuits are obtained. The conclusions establish the prospects of using this model and algorithms for the development of a software solution for the relay protection server and for future integration into the integrated power system.