Jozsef Molnar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jozsef Molnar has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Diana Novak
Institute of General Engineering, Empress Catherine II Saint Petersburg Mining University, 2, 21st Line, St. Petersburg 199106, Russia
2 shared publications A Johnson
Physics Department Frescati, Royal Institute of Technology, Frescativägen 24, S-10405 Stockholm, Sweden
1 shared publicationA Kerek
Physics Department Frescati, Royal Institute of Technology, Frescativägen 24, S-10405 Stockholm, Sweden
1 shared publicationA. Kerek
Royal Institute of Technology, Stockholm, Sweden
1 shared publication- Angelika Welte
Currency Department , 6315 Bank of Canada , 234 Wellington Street , Ottawa , ON K1A 0G9 , Canada
1 shared publication Attila Ozsvár
MTA-SZTE Research Group for Cortical Microcircuits of the Hungarian Academy of Sciences, Department of Physiology, Anatomy and Neuroscience, University of Szeged, Szeged, Hungary
1 shared publication
Latest Publications
- Open Access
- 1 April 2021
- Published by Springer Nature in Business Economics
- Vol. 56 (2) , 87-97
The market for acquiring card payments from small and medium-sized Canadian merchants
This article builds on industry data and a unique dataset of small and medium-sized merchants to provide insights into the acquirer-merchant market in Cana
- 1 April 2021
- Published by Springer Nature in Business Economics
- Vol. 56 (2) , 87-97
Open AccessThe market for acquiring card payments from small and medium-sized Canadian merchants
This article builds on industry data and a unique dataset of small and medium-sized merchants to provide insights into the acquirer-merchant market in Cana
- Open Access
- 10 February 2021
- Published by Springer Nature in Nature Communications
- Vol. 12 (1) , 1-11
Automatic deep learning-driven label-free image-guided patch clamp system
Patch clamp recording of neurons is a labor-intensive and time-consuming procedure. Here, we demonstrate a tool that fully automatically performs electrophysiological recordings in label-free tissue slices. The automation covers the detection of cells in label-free images, calibration of the micropipette movement, approach to the cell with the pipette, formation of the whole-cell configuration, and recording. The cell detection is based on deep learning. The model is trained on a new image database of neurons in unlabeled brain tissue slices. The pipette tip detection and approaching phase use image analysis techniques for precise movements. High-quality measurements are performed on hundreds of human and rodent neurons. We also demonstrate that further molecular and anatomical analysis can be performed on the recorded cells. The software has a diary module that automatically logs patch clamp events. Our tool can multiply the number of daily measurements to help brain research.
- 10 February 2021
- Published by Springer Nature in Nature Communications
- Vol. 12 (1) , 1-11
Open AccessAutomatic deep learning-driven label-free image-guided patch clamp system
Patch clamp recording of neurons is a labor-intensive and time-consuming procedure. Here, we demonstrate a tool that fully automatically performs electrophysiological recordings in label-free tissue slices. The automation covers the detection of cells in label-free images, calibration of the micropipette movement, approach to the cell with the pipette, formation of the whole-cell configuration, and recording. The cell detection is based on deep learning. The model is trained on a new image database of neurons in unlabeled brain tissue slices. The pipette tip detection and approaching phase use image analysis techniques for precise movements. High-quality measurements are performed on hundreds of human and rodent neurons. We also demonstrate that further molecular and anatomical analysis can be performed on the recorded cells. The software has a diary module that automatically logs patch clamp events. Our tool can multiply the number of daily measurements to help brain research.
- Open Access
- 1 April 2018
- Published by Elsevier in Computer Vision and Image Understanding
- Vol. 169, 90-107
A differential geometry approach to camera-independent image correspondence
- 1 April 2018
- Published by Elsevier in Computer Vision and Image Understanding
- Vol. 169, 90-107
Open AccessA differential geometry approach to camera-independent image correspondence
- Open Access
- 24 April 2009
- Published by Hindawi Limited in Andrologia
- Vol. 2 (2) , 81-88
Der Genitalbefund bei andrologischen Patienten III.) Nebenhodenveränderungen, Pyospermie, Semikastration und Degeneration (Atrophie) der Hoden.
- 24 April 2009
- Published by Hindawi Limited in Andrologia
- Vol. 2 (2) , 81-88
Open AccessDer Genitalbefund bei andrologischen Patienten III.) Nebenhodenveränderungen, Pyospermie, Semikastration und Degeneration (Atrophie) der Hoden.
- 1 March 2007
- Published by BMJ in Journal of Investigative Medicine
- Vol. 55 (2) , S362.2-S362
82 INHIBITION OF THE HERG CHANNEL BY ASPIRIN: PH OR DIRECT EFFECT?
Aspirin (ASA) has been widely used for many years for relieving pain and fever and in preventing heart attack and stroke. ASA overdose can result in an anion gap, metabolic acidosis, tinnitus, and, in severe cases, encephalopathy and cardiovascular collapse. There are studies showing the inhibitory effect of ASA on heat-evoked currents in rat dorsal root ganglion neurons and the augmented effect of ASA on the NMDA type of glutamate responses in spiral ganglion neurons. The effect of ASA on cardiac ion channels has not been studied. We evaluated the effect of ASA on cardiac IKr channel using HERG expressed on Xenopus oocytes. A two-microelectrode voltage clamp technique was used for recording, and the recording solution contained 96 mM NaCl, 5.0 mM KCl, 2.0 mM CaCl2, 1.0 mM MgCl2, and 5 mM HEPES, and the pH of the solution was adjusted with NaOH to 7.4. ASA was dissolved in the recording solution. At a concentration less than 1 mM, ASA has little effect on HERG current. ASA 1 mM and 2 mM inhibited current by 12 ± 2 and 22 ± 4%, respectively. ASA 3 mM inhibited current by 80 ± 6%. Considering the acidifying influence of ASA, the pH values of 1, 2, and 3 mM ASA solutions were determined as 7.1, 6.5, and 4.9. The pH of the recording solutions was adjusted to the corresponding pH, and the results showed that pH 7.1, 6.5, and 4.9 reduced HERG current by 6 ± 2, 10 ± 2, and 49 ± 5%. ASA 1, 2, and 3 mM caused greater inhibition of current than the recording solutions with the corresponding pH adjustment. There were significant differences in current inhibition between 2 mM ASA and the pH 6.5 recording solution (p < .05) and between 3 mM ASA and pH 4.9 recording solution (p < .01). ASA inhibits HERG current not only through acidification but also by a direct effect. The potent inhibition at 3 mM (54 mg/dL) further suggests that ASA at therapeutic doses and at doses seen with acute and chronic salicylism (40-120 mg/dL) may be arrhythmogenic owing to potent inhibition of the cardiac IKr channel.
- 1 March 2007
- Published by BMJ in Journal of Investigative Medicine
- Vol. 55 (2) , S362.2-S362
82 INHIBITION OF THE HERG CHANNEL BY ASPIRIN: PH OR DIRECT EFFECT?
Aspirin (ASA) has been widely used for many years for relieving pain and fever and in preventing heart attack and stroke. ASA overdose can result in an anion gap, metabolic acidosis, tinnitus, and, in severe cases, encephalopathy and cardiovascular collapse. There are studies showing the inhibitory effect of ASA on heat-evoked currents in rat dorsal root ganglion neurons and the augmented effect of ASA on the NMDA type of glutamate responses in spiral ganglion neurons. The effect of ASA on cardiac ion channels has not been studied. We evaluated the effect of ASA on cardiac IKr channel using HERG expressed on Xenopus oocytes. A two-microelectrode voltage clamp technique was used for recording, and the recording solution contained 96 mM NaCl, 5.0 mM KCl, 2.0 mM CaCl2, 1.0 mM MgCl2, and 5 mM HEPES, and the pH of the solution was adjusted with NaOH to 7.4. ASA was dissolved in the recording solution. At a concentration less than 1 mM, ASA has little effect on HERG current. ASA 1 mM and 2 mM inhibited current by 12 ± 2 and 22 ± 4%, respectively. ASA 3 mM inhibited current by 80 ± 6%. Considering the acidifying influence of ASA, the pH values of 1, 2, and 3 mM ASA solutions were determined as 7.1, 6.5, and 4.9. The pH of the recording solutions was adjusted to the corresponding pH, and the results showed that pH 7.1, 6.5, and 4.9 reduced HERG current by 6 ± 2, 10 ± 2, and 49 ± 5%. ASA 1, 2, and 3 mM caused greater inhibition of current than the recording solutions with the corresponding pH adjustment. There were significant differences in current inhibition between 2 mM ASA and the pH 6.5 recording solution (p < .05) and between 3 mM ASA and pH 4.9 recording solution (p < .01). ASA inhibits HERG current not only through acidification but also by a direct effect. The potent inhibition at 3 mM (54 mg/dL) further suggests that ASA at therapeutic doses and at doses seen with acute and chronic salicylism (40-120 mg/dL) may be arrhythmogenic owing to potent inhibition of the cardiac IKr channel.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 4 (10823654) , 2930-2932
Internals and evaluation of the miniPET-II detector module
We report on the architecture of the system-on- module (SoM) developed by our group for miniPET-II, the second version of our small animal PET scanner. The paper describes the hardware and software implementation details of the SoM we realized inside the miniPET-II detector module, the embedded Linux operation system, and the the initial results of bandwidth test measurements on the assembled SoM. Detailed description is given on the interfacing of the updated miniPET IP Core to the SoM, on the efficient data transfer method that implements device-to-device DMA transfer, and on the usage of User Datagram Protocol (UDP/IP) for high speed data transfer.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 4 (10823654) , 2930-2932
Internals and evaluation of the miniPET-II detector module
We report on the architecture of the system-on- module (SoM) developed by our group for miniPET-II, the second version of our small animal PET scanner. The paper describes the hardware and software implementation details of the SoM we realized inside the miniPET-II detector module, the embedded Linux operation system, and the the initial results of bandwidth test measurements on the assembled SoM. Detailed description is given on the interfacing of the updated miniPET IP Core to the SoM, on the efficient data transfer method that implements device-to-device DMA transfer, and on the usage of User Datagram Protocol (UDP/IP) for high speed data transfer.
- 1 January 2002
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 477 (1-3) , 82-87
A TOF-PET system for educational purposes
- 1 January 2002
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 477 (1-3) , 82-87
A TOF-PET system for educational purposes