Sheng Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sheng Xu has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
- Bradford J. Wood
Center for Interventional Oncology, NCI, NIH, Bethesda, MD, USA
13 shared publications - John W. Karanian
Center for Interventional Oncology, National Institutes of Health Clinical Center, Bethesda, MD, USA
3 shared publications - Ming Li
Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, USA
3 shared publications - Reza Seifabadi
National Institutes of Health Clinical Ctr. (United States)
3 shared publications - William F. Pritchard
National Institutes of Health Clinical Center, 10 Center Drive, Bethesda, Maryland, 20892-1504, UNITED STATES
3 shared publications - Zion Tsz Ho Tse
Queen Mary University of London
3 shared publications
Latest Publications
- Open Access
Advantages of a Photodiode Detector Endoscopy System in Fluorescence-Guided Percutaneous Liver Biopsies
Image-guided liver biopsies can improve their success rate when combined with the optical detection of Indocyanine Green (ICG) fluorescence accumulated in tumors. Previous works used a camera coupled to a thin borescope to capture and quantify images from fluorescence emission during procedures; however, light-scattering prevented the formation of sharp images, and the time response for weakly fluorescent tumors was very low. Instead, replacing the camera with a photodiode detector shows an improved temporal resolution in a more compact and lighter device. This work presents the new design in a comparative study between both detection technologies, including an assessment of the temporal response and sensitivity to the presence of background fluorescence.
Open AccessAdvantages of a Photodiode Detector Endoscopy System in Fluorescence-Guided Percutaneous Liver Biopsies
Image-guided liver biopsies can improve their success rate when combined with the optical detection of Indocyanine Green (ICG) fluorescence accumulated in tumors. Previous works used a camera coupled to a thin borescope to capture and quantify images from fluorescence emission during procedures; however, light-scattering prevented the formation of sharp images, and the time response for weakly fluorescent tumors was very low. Instead, replacing the camera with a photodiode detector shows an improved temporal resolution in a more compact and lighter device. This work presents the new design in a comparative study between both detection technologies, including an assessment of the temporal response and sensitivity to the presence of background fluorescence.
- 29 September 2022
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 18 (3) , 537-544
Patient-specific needle guidance templates drilled intraprocedurally for image guided intervention: feasibility study in swine
Purpose Thermal ablation of large tumors may benefit from simultaneous placement of multiple needles, but accurate placement becomes challenging as the number of needles increases. The aim of this work was to evaluate use of personalized needle guidance grid templates based on intraprocedural CT and fabricated at the point of care to implement ablation treatment plans with multiple needles in vivo. Methods A plastic frame was designed to hold two parallel plastic guide plates in a rigid relationship, fixed over the abdomen by a mounting arm. Steel ball targets (1.5 mm) were implanted under ultrasound in the livers of two domestic swine under general anesthesia. Following breath-hold CT of the subject and frame, the targets and frame were identified using customized 3D Slicer-based planning software. Multiple needle trajectories targeting the balls were planned, including complex off-plane trajectories. A machining program for drilling the hole pattern corresponding to the planned needle trajectories was generated. The pattern was drilled in the two plates with a numerical-controlled milling machine in the suite. The plates were attached to the frame and needles passed through the paired holes to the calculated depth. Placement accuracy was defined as needle tip-to-target distance on post-placement CT. Results The planning process and manufacturing required approximately 6 and 15 min, respectively. Needles were rapidly inserted (n = 11) to the target points without complications or traversing nontarget anatomy. The mean needle tip-to-target distance error was 3.4 ± 2.2, range 0–7 mm. Conclusion Rapid and accurate needle placement was feasible using a subject-specific, custom-drilled, needle guidance grid template fabricated intraprocedurally. Targeting accuracy and performance were similar to more complex and expensive tracking systems which may enable accurate intraprocedural implementation of treatment plans in the liver or other organs. This may be of value in complex ablation cases or in areas where more advanced guidance systems are not available.
- 29 September 2022
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 18 (3) , 537-544
Patient-specific needle guidance templates drilled intraprocedurally for image guided intervention: feasibility study in swine
Purpose Thermal ablation of large tumors may benefit from simultaneous placement of multiple needles, but accurate placement becomes challenging as the number of needles increases. The aim of this work was to evaluate use of personalized needle guidance grid templates based on intraprocedural CT and fabricated at the point of care to implement ablation treatment plans with multiple needles in vivo. Methods A plastic frame was designed to hold two parallel plastic guide plates in a rigid relationship, fixed over the abdomen by a mounting arm. Steel ball targets (1.5 mm) were implanted under ultrasound in the livers of two domestic swine under general anesthesia. Following breath-hold CT of the subject and frame, the targets and frame were identified using customized 3D Slicer-based planning software. Multiple needle trajectories targeting the balls were planned, including complex off-plane trajectories. A machining program for drilling the hole pattern corresponding to the planned needle trajectories was generated. The pattern was drilled in the two plates with a numerical-controlled milling machine in the suite. The plates were attached to the frame and needles passed through the paired holes to the calculated depth. Placement accuracy was defined as needle tip-to-target distance on post-placement CT. Results The planning process and manufacturing required approximately 6 and 15 min, respectively. Needles were rapidly inserted (n = 11) to the target points without complications or traversing nontarget anatomy. The mean needle tip-to-target distance error was 3.4 ± 2.2, range 0–7 mm. Conclusion Rapid and accurate needle placement was feasible using a subject-specific, custom-drilled, needle guidance grid template fabricated intraprocedurally. Targeting accuracy and performance were similar to more complex and expensive tracking systems which may enable accurate intraprocedural implementation of treatment plans in the liver or other organs. This may be of value in complex ablation cases or in areas where more advanced guidance systems are not available.
- Open Access
End-to-end Ultrasound Frame to Volume Registration
Fusing intra-operative 2D transrectal ultrasound (TRUS) image with pre-operative 3D magnetic resonance (MR) volume to guide prostate biopsy can significantly increase the yield. However, such a multimodal 2D/3D registration problem is a very challenging task. In this paper, we propose an end-to-end frame-to-volume registration network (FVR-Net), which can efficiently bridge the previous research gaps by aligning a 2D TRUS frame with a 3D TRUS volume without requiring hardware tracking. The proposed FVR-Net utilizes a dual-branch feature extraction module to extract the information from TRUS frame and volume to estimate transformation parameters. We also introduce a differentiable 2D slice sampling module which allows gradients backpropagating from an unsupervised image similarity loss for content correspondence learning. Our model shows superior efficiency for real-time interventional guidance with highly competitive registration accuracy.
Open AccessEnd-to-end Ultrasound Frame to Volume Registration
Fusing intra-operative 2D transrectal ultrasound (TRUS) image with pre-operative 3D magnetic resonance (MR) volume to guide prostate biopsy can significantly increase the yield. However, such a multimodal 2D/3D registration problem is a very challenging task. In this paper, we propose an end-to-end frame-to-volume registration network (FVR-Net), which can efficiently bridge the previous research gaps by aligning a 2D TRUS frame with a 3D TRUS volume without requiring hardware tracking. The proposed FVR-Net utilizes a dual-branch feature extraction module to extract the information from TRUS frame and volume to estimate transformation parameters. We also introduce a differentiable 2D slice sampling module which allows gradients backpropagating from an unsupervised image similarity loss for content correspondence learning. Our model shows superior efficiency for real-time interventional guidance with highly competitive registration accuracy.
- 21 May 2021
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 44 (9) , 1439-1447
Electromagnetic Tracking and Optical Molecular Imaging Guidance for Liver Biopsy and Point-of-Care Tissue Assessment in Phantom and Woodchuck Hepatocellular Carcinoma
Purpose To evaluate an integrated liver biopsy platform that combined CT image fusion, electromagnetic (EM) tracking, and optical molecular imaging (OMI) of indocyanine green (ICG) to target hepatocellular carcinoma (HCC) lesions and a point-of-care (POC) OMI to assess biopsy cores, all based on tumor retention of ICG compared to normal liver, in phantom and animal model. Material A custom CT image fusion and EM-tracked guidance platform was modified to integrate the measurement of ICG fluorescence intensity signals in targeted liver tissue with an OMI stylet or a POC OMI system. Accuracy was evaluated in phantom and a woodchuck with HCC, 1 day after administration of ICG. Fresh biopsy cores and paraffin-embedded formalin-fixed liver tissue blocks were evaluated with the OMI stylet or POC system to identify ICG fluorescence signal and ICG peak intensity. Results The mean distance between the initial guided needle delivery location and the peak ICG signal was 5.0 ± 4.7 mm in the phantom. There was complete agreement between the reviewers of the POC-acquired ICG images, cytology, and histopathology in differentiating HCC-positive from HCC-negative biopsy cores. The peak ICG fluorescence intensity signal in the ex vivo liver blocks was 39 ± 12 and 281 ± 150 for HCC negative and HCC positive, respectively. Conclusion Biopsy guidance with fused CT imaging, EM tracking, and ICG tracking with an OMI stylet to detect HCC is feasible. Immediate assessment of ICG uptake in biopsy cores with the POC OMI system is feasible and correlates with the presence of HCC in the tissue.
- 21 May 2021
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 44 (9) , 1439-1447
Electromagnetic Tracking and Optical Molecular Imaging Guidance for Liver Biopsy and Point-of-Care Tissue Assessment in Phantom and Woodchuck Hepatocellular Carcinoma
Purpose To evaluate an integrated liver biopsy platform that combined CT image fusion, electromagnetic (EM) tracking, and optical molecular imaging (OMI) of indocyanine green (ICG) to target hepatocellular carcinoma (HCC) lesions and a point-of-care (POC) OMI to assess biopsy cores, all based on tumor retention of ICG compared to normal liver, in phantom and animal model. Material A custom CT image fusion and EM-tracked guidance platform was modified to integrate the measurement of ICG fluorescence intensity signals in targeted liver tissue with an OMI stylet or a POC OMI system. Accuracy was evaluated in phantom and a woodchuck with HCC, 1 day after administration of ICG. Fresh biopsy cores and paraffin-embedded formalin-fixed liver tissue blocks were evaluated with the OMI stylet or POC system to identify ICG fluorescence signal and ICG peak intensity. Results The mean distance between the initial guided needle delivery location and the peak ICG signal was 5.0 ± 4.7 mm in the phantom. There was complete agreement between the reviewers of the POC-acquired ICG images, cytology, and histopathology in differentiating HCC-positive from HCC-negative biopsy cores. The peak ICG fluorescence intensity signal in the ex vivo liver blocks was 39 ± 12 and 281 ± 150 for HCC negative and HCC positive, respectively. Conclusion Biopsy guidance with fused CT imaging, EM tracking, and ICG tracking with an OMI stylet to detect HCC is feasible. Immediate assessment of ICG uptake in biopsy cores with the POC OMI system is feasible and correlates with the presence of HCC in the tissue.
- 15 January 2021
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 27 (1) , 20-27
Determination of disease severity in COVID-19 patients using deep learning in chest X-ray images
Chest X-ray plays a key role in diagnosis and management of COVID-19 patients and imaging features associated with clinical elements may assist with the development or validation of automated image analysis tools. We aimed to identify associations between clinical and radiographic features as well as to assess the feasibility of deep learning applied to chest X-rays in the setting of an acute COVID-19 outbreak. A retrospective study of X-rays, clinical, and laboratory data was performed from 48 SARS-CoV-2 RT-PCR positive patients (age 60±17 years, 15 women) between February 22 and March 6, 2020 from a tertiary care hospital in Milan, Italy. Sixty-five chest X-rays were reviewed by two radiologists for alveolar and interstitial opacities and classified by severity on a scale from 0 to 3. Clinical factors (age, symptoms, comorbidities) were investigated for association with opacity severity and also with placement of central line or endotracheal tube. Deep learning models were then trained for two tasks: lung segmentation and opacity detection. Imaging characteristics were compared to clinical datapoints using the unpaired student’s t-test or Mann-Whitney U test. Cohen’s kappa analysis was used to evaluate the concordance of deep learning to conventional radiologist interpretation. Fifty-six percent of patients presented with alveolar opacities, 73% had interstitial opacities, and 23% had normal X-rays. The presence of alveolar or interstitial opacities was statistically correlated with age (p = 0.008) and comorbidities (p = 0.005). The extent of alveolar or interstitial opacities on baseline X-ray was significantly associated with the presence of endotracheal tube (p = 0.0008 and p = 0.049) or central line (p = 0.003 and p = 0.007). In comparison to human interpretation, the deep learning model achieved a kappa concordance of 0.51 for alveolar opacities and 0.71 for interstitial opacities. Chest X-ray analysis in an acute COVID-19 outbreak showed that the severity of opacities was associated with advanced age, comorbidities, as well as acuity of care. Artificial intelligence tools based upon deep learning of COVID-19 chest X-rays are feasible in the acute outbreak setting.
- 15 January 2021
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 27 (1) , 20-27
Determination of disease severity in COVID-19 patients using deep learning in chest X-ray images
Chest X-ray plays a key role in diagnosis and management of COVID-19 patients and imaging features associated with clinical elements may assist with the development or validation of automated image analysis tools. We aimed to identify associations between clinical and radiographic features as well as to assess the feasibility of deep learning applied to chest X-rays in the setting of an acute COVID-19 outbreak. A retrospective study of X-rays, clinical, and laboratory data was performed from 48 SARS-CoV-2 RT-PCR positive patients (age 60±17 years, 15 women) between February 22 and March 6, 2020 from a tertiary care hospital in Milan, Italy. Sixty-five chest X-rays were reviewed by two radiologists for alveolar and interstitial opacities and classified by severity on a scale from 0 to 3. Clinical factors (age, symptoms, comorbidities) were investigated for association with opacity severity and also with placement of central line or endotracheal tube. Deep learning models were then trained for two tasks: lung segmentation and opacity detection. Imaging characteristics were compared to clinical datapoints using the unpaired student’s t-test or Mann-Whitney U test. Cohen’s kappa analysis was used to evaluate the concordance of deep learning to conventional radiologist interpretation. Fifty-six percent of patients presented with alveolar opacities, 73% had interstitial opacities, and 23% had normal X-rays. The presence of alveolar or interstitial opacities was statistically correlated with age (p = 0.008) and comorbidities (p = 0.005). The extent of alveolar or interstitial opacities on baseline X-ray was significantly associated with the presence of endotracheal tube (p = 0.0008 and p = 0.049) or central line (p = 0.003 and p = 0.007). In comparison to human interpretation, the deep learning model achieved a kappa concordance of 0.51 for alveolar opacities and 0.71 for interstitial opacities. Chest X-ray analysis in an acute COVID-19 outbreak showed that the severity of opacities was associated with advanced age, comorbidities, as well as acuity of care. Artificial intelligence tools based upon deep learning of COVID-19 chest X-rays are feasible in the acute outbreak setting.
- 6 January 2021
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 44 (5) , 774-781
Comparison of Smartphone Augmented Reality, Smartglasses Augmented Reality, and 3D CBCT-guided Fluoroscopy Navigation for Percutaneous Needle Insertion: A Phantom Study
Purpose To compare needle placement performance using an augmented reality (AR) navigation platform implemented on smartphone or smartglasses devices to that of CBCT-guided fluoroscopy in a phantom. Materials and Methods An AR application was developed to display a planned percutaneous needle trajectory on the smartphone (iPhone7) and smartglasses (HoloLens1) devices in real time. Two AR-guided needle placement systems and CBCT-guided fluoroscopy with navigation software (XperGuide, Philips) were compared using an anthropomorphic phantom (CIRS, Norfolk, VA). Six interventional radiologists each performed 18 independent needle placements using smartphone (n = 6), smartglasses (n = 6), and XperGuide (n = 6) guidance. Placement error was defined as the distance from the needle tip to the target center. Placement time was recorded. For XperGuide, dose-area product (DAP, mGy*cm2) and fluoroscopy time (sec) were recorded. Statistical comparisons were made using a two-way repeated measures ANOVA. Results The placement error using the smartphone, smartglasses, or XperGuide was similar (3.98 ± 1.68 mm, 5.18 ± 3.84 mm, 4.13 ± 2.38 mm, respectively, p = 0.11). Compared to CBCT-guided fluoroscopy, the smartphone and smartglasses reduced placement time by 38% (p = 0.02) and 55% (p = 0.001), respectively. The DAP for insertion using XperGuide was 3086 ± 2920 mGy*cm2, and no intra-procedural radiation was required for augmented reality. Conclusions Smartphone- and smartglasses-based augmented reality reduced needle placement time and radiation exposure while maintaining placement accuracy compared to a clinically validated needle navigation platform.
- 6 January 2021
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 44 (5) , 774-781
Comparison of Smartphone Augmented Reality, Smartglasses Augmented Reality, and 3D CBCT-guided Fluoroscopy Navigation for Percutaneous Needle Insertion: A Phantom Study
Purpose To compare needle placement performance using an augmented reality (AR) navigation platform implemented on smartphone or smartglasses devices to that of CBCT-guided fluoroscopy in a phantom. Materials and Methods An AR application was developed to display a planned percutaneous needle trajectory on the smartphone (iPhone7) and smartglasses (HoloLens1) devices in real time. Two AR-guided needle placement systems and CBCT-guided fluoroscopy with navigation software (XperGuide, Philips) were compared using an anthropomorphic phantom (CIRS, Norfolk, VA). Six interventional radiologists each performed 18 independent needle placements using smartphone (n = 6), smartglasses (n = 6), and XperGuide (n = 6) guidance. Placement error was defined as the distance from the needle tip to the target center. Placement time was recorded. For XperGuide, dose-area product (DAP, mGy*cm2) and fluoroscopy time (sec) were recorded. Statistical comparisons were made using a two-way repeated measures ANOVA. Results The placement error using the smartphone, smartglasses, or XperGuide was similar (3.98 ± 1.68 mm, 5.18 ± 3.84 mm, 4.13 ± 2.38 mm, respectively, p = 0.11). Compared to CBCT-guided fluoroscopy, the smartphone and smartglasses reduced placement time by 38% (p = 0.02) and 55% (p = 0.001), respectively. The DAP for insertion using XperGuide was 3086 ± 2920 mGy*cm2, and no intra-procedural radiation was required for augmented reality. Conclusions Smartphone- and smartglasses-based augmented reality reduced needle placement time and radiation exposure while maintaining placement accuracy compared to a clinically validated needle navigation platform.
- 16 March 2020
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11315, 30
Accuracy study of smartglasses/smartphone AR systems for percutaneous needle interventions
Purpose: This study aims to investigate the accuracy of a cross platform augmented reality (AR) system for percutaneous needle interventions irrespective of operator error. In particular, we study the effect of the relative position and orientation of the AR device and the marker, the location of the target, and the angle of needle on the overlay accuracy. Method: A needle guidance AR platform developed using Unity and Vuforia SDK platforms was used to display a planned needle trajectory for targets via mobile and wearable devices. To evaluate the system accuracy, a custom phantom embedded with metal fiducial markers and an adjustable needle guide was designed to mimic different relative position and orientation scenarios of the smart device and the marker. After segmenting images of CT-visible fiducial markers as well as different needle trajectories, error was defined by comparing them to the corresponding augmented target/needle trajectory projected by smartphone and smartglasses devices. Results: The augmentation error for targets and needle trajectories were reported as a function of marker position and orientation, as well as the location of the targets. Overall, the image overlay error for needle trajectory was 0.28±0.32° (Max = 0.856°) and 0.41±0.23° (Max = 0.805°) using the iPhone and HoloLens glasses, respectively. The overall image overlay error for targets was 1.75±0.59 mm for iPhone, and 1.74±0.86 mm for HoloLens. Conclusions: The image overlay error caused by different sources can be quantified for different AR devices.
- 16 March 2020
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11315, 30
Accuracy study of smartglasses/smartphone AR systems for percutaneous needle interventions
Purpose: This study aims to investigate the accuracy of a cross platform augmented reality (AR) system for percutaneous needle interventions irrespective of operator error. In particular, we study the effect of the relative position and orientation of the AR device and the marker, the location of the target, and the angle of needle on the overlay accuracy. Method: A needle guidance AR platform developed using Unity and Vuforia SDK platforms was used to display a planned needle trajectory for targets via mobile and wearable devices. To evaluate the system accuracy, a custom phantom embedded with metal fiducial markers and an adjustable needle guide was designed to mimic different relative position and orientation scenarios of the smart device and the marker. After segmenting images of CT-visible fiducial markers as well as different needle trajectories, error was defined by comparing them to the corresponding augmented target/needle trajectory projected by smartphone and smartglasses devices. Results: The augmentation error for targets and needle trajectories were reported as a function of marker position and orientation, as well as the location of the targets. Overall, the image overlay error for needle trajectory was 0.28±0.32° (Max = 0.856°) and 0.41±0.23° (Max = 0.805°) using the iPhone and HoloLens glasses, respectively. The overall image overlay error for targets was 1.75±0.59 mm for iPhone, and 1.74±0.86 mm for HoloLens. Conclusions: The image overlay error caused by different sources can be quantified for different AR devices.
- Open Access
- 23 January 2019
- Published by MDPI AG in Journal of Imaging
- Vol. 5 (2) , 23
Origami Lesion-Targeting Device for CT-Guided Interventions
The objective of this study is to preliminarily evaluate a lesion-targeting device for CT-guided interventions. The device is created by laser cutting the structure from a sheet of medical grade paperboard, 3D printing two radiocontrast agent grids onto the surface and folding the structure into a rectangular prism with a viewing window. An abdominal imaging phantom was used to evaluate the device through CT imaging and the targeting of lesions for needle insertion. The lesion-targeting trials resulted in a mean targeting error of 2.53 mm (SD 0.59 mm, n = 30). The device is rigid enough to adequately support standard biopsy needles, and it attaches to the patient, reducing the risk of tissue laceration by needles held rigidly in place by an external manipulator. Additional advantages include adequate support for the insertion of multiple surgical tools at once for procedures such as composite ablation and the potential to guide off-axial needle insertion. The low-cost and disposability of the device make it well-suited for the minimally invasive image-guided therapy environment.
- 23 January 2019
- Published by MDPI AG in Journal of Imaging
- Vol. 5 (2) , 23
Open AccessOrigami Lesion-Targeting Device for CT-Guided Interventions
The objective of this study is to preliminarily evaluate a lesion-targeting device for CT-guided interventions. The device is created by laser cutting the structure from a sheet of medical grade paperboard, 3D printing two radiocontrast agent grids onto the surface and folding the structure into a rectangular prism with a viewing window. An abdominal imaging phantom was used to evaluate the device through CT imaging and the targeting of lesions for needle insertion. The lesion-targeting trials resulted in a mean targeting error of 2.53 mm (SD 0.59 mm, n = 30). The device is rigid enough to adequately support standard biopsy needles, and it attaches to the patient, reducing the risk of tissue laceration by needles held rigidly in place by an external manipulator. Additional advantages include adequate support for the insertion of multiple surgical tools at once for procedures such as composite ablation and the potential to guide off-axial needle insertion. The low-cost and disposability of the device make it well-suited for the minimally invasive image-guided therapy environment.
- 1 January 2018
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 210 (1) , 207-213
Smartphone-Guided Needle Angle Selection During CT-Guided Procedures
OBJECTIVE. In CT-guided intervention, translation from a planned needle insertion angle to the actual insertion angle is estimated only with the physician's visuospatial abilities. An iPhone app was developed to reduce reliance on operator ability to estimate and reproduce angles. MATERIALS AND METHODS. The iPhone app overlays the planned angle on the smartphone's camera display in real-time based on the smartphone's orientation. The needle's angle is selected by visually comparing the actual needle with the guideline in the display. If the smartphone's screen is perpendicular to the planned path, the smartphone shows the Bull's-Eye View mode, in which the angle is selected after the needle's hub overlaps the tip in the camera. In phantom studies, we evaluated the accuracies of the hardware, the Guideline mode, and the Bull's-Eye View mode and showed the app's clinical efficacy. A proof-of-concept clinical case was also performed. RESULTS. The hardware accuracy was 0.37° ± 0.27° (mean ± SD). The mean erro...
- 1 January 2018
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 210 (1) , 207-213
Smartphone-Guided Needle Angle Selection During CT-Guided Procedures
OBJECTIVE. In CT-guided intervention, translation from a planned needle insertion angle to the actual insertion angle is estimated only with the physician's visuospatial abilities. An iPhone app was developed to reduce reliance on operator ability to estimate and reproduce angles. MATERIALS AND METHODS. The iPhone app overlays the planned angle on the smartphone's camera display in real-time based on the smartphone's orientation. The needle's angle is selected by visually comparing the actual needle with the guideline in the display. If the smartphone's screen is perpendicular to the planned path, the smartphone shows the Bull's-Eye View mode, in which the angle is selected after the needle's hub overlaps the tip in the camera. In phantom studies, we evaluated the accuracies of the hardware, the Guideline mode, and the Bull's-Eye View mode and showed the app's clinical efficacy. A proof-of-concept clinical case was also performed. RESULTS. The hardware accuracy was 0.37° ± 0.27° (mean ± SD). The mean erro...
- 17 January 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 17 (7) , 1952-1963
Fiber-Optic Force Sensors for MRI-Guided Interventions and Rehabilitation: A Review
Magnetic resonance imaging (MRI) provides both anatomical imaging with excellent soft tissue contrast and functional MRI imaging (fMRI) of physiological parameters. The last two decades have witnessed the manifestation of increased interest in MRI-guided minimally invasive intervention procedures and fMRI for rehabilitation and neuroscience research. Accompanying the aspiration to utilize MRI to provide imaging feedback during interventions and brain activity for neuroscience study, there is an accumulated effort to utilize force sensors compatible with the MRI environment to meet the growing demand of these procedures, with the goal of enhanced interventional safety and accuracy, improved efficacy and rehabilitation outcome. This paper summarizes the fundamental principles, the state of the art development, and challenges of fiber-optic force sensors for MRI-guided interventions and rehabilitation. It provides an overview of MRI-compatible fiber-optic force sensors based on different sensing principles, including light intensity modulation, wavelength modulation, and phase modulation. Extensive design prototypes are reviewed to illustrate the detailed implementation of these principles. Advantages and disadvantages of the sensor designs are compared and analyzed. A perspective on the future development of fiber-optic sensors is also presented, which may have additional broad clinical applications. Future surgical interventions or rehabilitation will rely on intelligent force sensors to provide situational awareness to augment or complement human perception in these procedures.
- 17 January 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 17 (7) , 1952-1963
Fiber-Optic Force Sensors for MRI-Guided Interventions and Rehabilitation: A Review
Magnetic resonance imaging (MRI) provides both anatomical imaging with excellent soft tissue contrast and functional MRI imaging (fMRI) of physiological parameters. The last two decades have witnessed the manifestation of increased interest in MRI-guided minimally invasive intervention procedures and fMRI for rehabilitation and neuroscience research. Accompanying the aspiration to utilize MRI to provide imaging feedback during interventions and brain activity for neuroscience study, there is an accumulated effort to utilize force sensors compatible with the MRI environment to meet the growing demand of these procedures, with the goal of enhanced interventional safety and accuracy, improved efficacy and rehabilitation outcome. This paper summarizes the fundamental principles, the state of the art development, and challenges of fiber-optic force sensors for MRI-guided interventions and rehabilitation. It provides an overview of MRI-compatible fiber-optic force sensors based on different sensing principles, including light intensity modulation, wavelength modulation, and phase modulation. Extensive design prototypes are reviewed to illustrate the detailed implementation of these principles. Advantages and disadvantages of the sensor designs are compared and analyzed. A perspective on the future development of fiber-optic sensors is also presented, which may have additional broad clinical applications. Future surgical interventions or rehabilitation will rely on intelligent force sensors to provide situational awareness to augment or complement human perception in these procedures.