Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Marie Didembourg has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Evaluation of neutralizing antibody titers against SARS-CoV-2 JN.1 omicron subvariant during pregnancy - A case series study

    by Marie Didembourg, Clara David, Laure Morimont, Eva Cransquint, Julien Favresse, Jonathan Douxfils, Constant Gillot

  • Open Access

    Hemostatic imbalance induced by tamoxifen in estrogen receptor‐positive breast cancer patients: An observational study

    by Marie Didembourg, Sara Reda, Johannes Oldenburg, Heiko Rühl, Jonathan Douxfils, Laure Morimont

    Background: Estrogen receptor (ER)‐positive (ER+) breast cancer accounts for approximately 75% of all breast cancers. Tamoxifen, a selective estrogen receptor modulator, is the standard adjuvant treatment. Although better tolerated than aromatase inhibitors, tamoxifen increases the risk of venous thromboembolism (VTE) 1.4‐fold.Aim: To assess the hemostatic imbalance induced by tamoxifen in adjuvant treatment of ER+ breast cancer.Method: Twenty‐five patients in remission from ER+ breast cancer under tamoxifen were included. One hundred and thirty one age‐ and BMI‐matched healthy controls were included to establish reference ranges of thrombin generation assay (TGA) parameters. TGA was performed in the absence and presence of exogenous activated protein C (APC) to calculate the normalized APC sensitivity ratio (nAPCsr), a marker of APC resistance.Results: All TG parameters except the endogenous thrombin potential (ETP) (−APC) were significantly impacted by tamoxifen (p < 0.001). In absence of APC, regardless of TGA parameters, at least 50% of results were outside the reference ranges except for ETP, which was above the upper reference limit in only two individuals. The most impacted parameter was the Peak Height with 52% (−APC) and 80% (+APC) of results above the upper reference range limit, respectively. The nAPCsr was significantly higher in tamoxifen users (mean ± standard deviation = 3.18 ± 0.91) compared to the control group (2.19 ± 0.92, p < 0.0001).Conclusion: This observational study showed that patients in remission from ER+ breast cancer taking tamoxifen had altered thrombin generation, as well as an acquired APC resistance. Moreover, this is the first study using the validated ETP‐based APC resistance assay in tamoxifen‐treated patients.


  • Open Access

    Analytical Sensitivity of Six SARS-CoV-2 Rapid Antigen Tests for Omicron versus Delta Variant

    by Jean-Louis Bayart, Jonathan Degosserie, Julien Favresse, Constant Gillot, Marie Didembourg, Happy Phanio Djokoto, Valérie Verbelen, Gatien Roussel, Céline Maschietto, François Mullier, et al.

    Rapid antigen detection (RAD) tests are commonly used for the diagnosis of SARS-CoV-2 infections. However, with the continuous emergence of new variants of concern (VOC), presenting various mutations potentially affecting the nucleocapsid protein, the analytical performances of these assays should be frequently reevaluated. One hundred and twenty samples were selected and tested with both RT-qPCR and six commercial RAD tests that are commonly sold in Belgian pharmacies. Of these, direct whole-genome sequencing identified the strains present in 116 samples, of which 70 were Delta and 46 were Omicron (BA.1 and BA.1.1 sub-lineages, respectively). The sensitivity across a wide range of Ct values (13.5 to 35.7; median = 21.3) ranged from 70.0% to 92.9% for Delta strains and from 69.6% to 78.3% for Omicron strains. When taking swabs with a low viral load (Ct > 25, corresponding to 10 copies/mL), only the Roche RAD test showed acceptable performances for the Delta strains (80.0%), while poor performances were observed for the other RAD tests (20.0% to 40.0%). All the tested devices had poor performances for the Omicron samples with a low viral load (0.0% to 23.1%). The poor performances observed with low viral loads, particularly for the Omicron strain, is an important limitation of RAD tests, which is not sufficiently highlighted in the instructions for use of these devices.


  • Open Access

    Analytical Sensitivity of Five SARS-CoV-2 Rapid Antigen Tests for Omicron Versus Delta Variant

    by Jean-Louis Bayart, Jonathan Degosserie, Julien Favresse, Constant Gillot, Marie Didembourg, Happy Phanio Djokoto, Valérie Verbelen, Gatien Roussel, Celine Maschietto, François Mullier, et al.

    Rapid antigen detection tests (RAD) are commonly used for the diagnosis of SARS-CoV-2 infections. However, with the continuous emergence of new variants of concern (VOC) presenting various mutations potentially affecting the nucleocapsid protein, the analytical performances of these assays should be frequently reevaluated. One-hundred and twenty samples were selected and tested with both RT-qPCR and five commercial RAD commonly sold in Belgian pharmacies. Of these, direct whole genome sequencing identified the strains present in 116 samples, of which 70 were Delta and 46 were Omicron. Sensitivity across a wide range of Ct values (13.5 to 35.7; median = 21.3) were comparable and ranged from 70.0% to 77.1% for Delta strains and from 69.6% to 78.3% for Omicron strains. When taking swabs with a low viral load (Ct > 25), poor performances were observed for the Delta strains (20.0 to 40.0%) and, even more so, for Omicron strains (0.0 to 23.1%). Two devices failed to detect all samples (n = 13) containing Omicron strains with a low viral load. The poor performance observed with low viral loads is an important limitation of RAD, which is not sufficiently highlighted in the instruction for use of these devices.


  • Spike vs. nucleocapsid serum antigens for COVID-19 diagnosis and severity assessment

    by Julien Favresse, Jean-Louis Bayart, Clara David, Marie Didembourg, Constant Gillot, Jean-Michel Dogné, Jonathan Douxfils

    Article Spike vs. nucleocapsid serum antigens for COVID-19 diagnosis and severity assessment was published on January 11, 2022 in the journal Clinical Chemistry and Laboratory Medicine (CCLM) (volume 0, issue 0).


  • Effect of tissue factor pathway inhibitor on thrombin generation assay

    by Marie Didembourg, Jonathan Douxfils, Audrey Carlo, François Mullier, Michael Hardy, Laure Morimont


  • Study of in vitro thrombin generation after neutralization of heparin

    by Michael Hardy, Jonathan Douxfils, Laure Morimont, Marie Didembourg, Audrey Carlo, Emmanuel de Maistre, Thomas Lecompte, François Mullier

    Introduction: Thrombin generation (TG) documents hypercoagulability. TG in platelet‐poor plasma is exquisitely sensitive to heparins, which thus must be neutralized before testing. Heparinase and hexadimethrine bromide (polybrene) have been used for that purpose, but their effects per se on TG have been poorly studied so far.Methods: (i) TG was studied in commercial normal pooled plasma (NPP; CryoCheck®, Cryopep) in absence or presence of neutralizing agents. (ii) NPP was spiked with increasing concentrations of unfractionated heparin (UFH; up to 1.0 IU/mL) or low‐molecular‐weight heparin (LMWH; enoxaparin up to 1.2 IU/mL) and TG studied after incubation of heparinase (Hepzyme®; 15 minutes) or polybrene (0.025 mg/mL; 10 minutes).Results: (i) With ThromboScreen reagent to initiate TG, addition of heparinase was associated with increased peak, whereas polybrene caused lengthening of lag time and time to peak, compared with nonsupplemented NPP. (ii) With polybrene, TG was completely restored over the whole range of UFH and LMWH studied. By contrast, heparinase failed to fully restore TG in presence of UFH concentrations ≥0.8 IU/mL or LMWH concentrations ≥1.0 IU/mL. Those effects were matched with detectable tiny residual amounts of non‐neutralized heparin (as assessed with an anti‐Xa assay) and were less pronounced with a higher picomolar concentration of tissue factor (DrugScreen reagent).Conclusion: Polybrene fully restored TG of heparinized plasma at the expense of an alteration of TG, pointing to the need to use adapted reference ranges. Heparinase failed to do so in presence of high concentrations of both heparins.


  • Influence of C-reactive protein on thrombin generation assay

    by Marie Didembourg, Jonathan Douxfils, François Mullier, Michael Hardy, Julien Favresse, Laure Morimont

    Article Influence of C-reactive protein on thrombin generation assay was published on June 1, 2021 in the journal Clinical Chemistry and Laboratory Medicine (CCLM) (volume 59, issue 7).