MBManuel Antonio Burgos

Manuel Antonio Burgos

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Manuel Antonio Burgos has a total of 56 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Empty nose syndrome: new insights from a CFD approach

    by Francisco Esteban-Ortega, Lina Rosique-López, Jaime A. Ochoa-Ríos, Rafael Rodríguez-Romero, Manuel A. Burgos-Olmos

    Objectives: Empty Nose Syndrome (ENS) is a debilitating condition which usually arises after aggressive turbinate reduction. However, objective tests to help in the diagnosis of this condition are lacking. Accurate diagnosis of ENS patients is critical for effective diagnosis and treatment. The article's objectives are to utilize computational fluid dynamics (CFD) to analyze nasal airflow resistance and symmetry in suspected ENS patients, classify them into distinct groups based on CFD data, and demonstrate the potential of CFD analysis in refining ENS diagnosis and guiding individualized treatment strategies. Methods: This study involved 48 patients diagnosed of ENS. However, we only considered those patients with documented prior turbinate surgery (eventually plus septal surgery), CT scan with signs of prior surgery, and a history of ENS with symptoms included in the ENS Q6. We employed computational fluid dynamics (CFD) to analyze nasal airflow resistance and symmetry. Patients were classified into three groups based on their CFD data: low resistance and normal symmetry, evident asymmetry, and normal CFD parameters. Results: Half of patients (24 out of 48) were found in the low resistance and normal symmetry group, indicating ‘typical’ ENS. A smaller group (8) exhibited evident asymmetry, suggesting unilateral ENS or failure of previous surgery. Finally, 16 patients whose CFD parameters are inside the normal range of flow and resistance were classified in the normal breathing group. Conclusions: Our findings highlight the value of CFD analysis in classifying ENS patients based on airflow characteristics, as CFD analysis seems helpful in refining the diagnosis of ENS. This classification system can potentially aid in tailoring individual treatment strategies and improving patient outcomes. Further research is necessary to validate these results and explore the clinical implications of different ENS subgroups. Level of evidence: Level 4 [1].


  • Open Access

    Assessing nasal airway resistance and symmetry: An approach to global perspective through computational fluid dynamics

    by Manuel A. Burgos, Markus Bastir, Alejandro Pérez‐Ramos, Daniel Sanz‐Prieto, Yann Heuzé, Laura Maréchal, Francisco Esteban‐Ortega

    This study aimed to explore the variability in nasal airflow patterns among different sexes and populations using computational fluid dynamics (CFD). We focused on evaluating the universality and applicability of dimensionless parameters R (bilateral nasal resistance) and ϕ (nasal flow asymmetry), initially established in a Caucasian Spanish cohort, across a broader spectrum of human populations to assess normal breathing function in healthy airways. In this retrospective study, CT scans from Cambodia (20 males, 20 females), Russia (20 males, 18 females), and Spain (19 males, 19 females) were analyzed. A standardized CFD workflow was implemented to calculate R‐ϕ parameters from these scans. Statistical analyses were conducted to assess and compare these parameters across different sexes and populations, emphasizing their distribution and variances. Our results indicated no significant sex‐based differences in the R parameter across the populations. However, moderate sexual dimorphism in the ϕ parameter was observed in the Cambodian group. Notably, no geographical differences were found in either R or ϕ parameters, suggesting consistent nasal airflow characteristics across the diverse human groups studied. The study also emphasized the importance of using dimensionless variables to effectively analyze the relationships between form and function in nasal airflow. The observed consistency of R‐ϕ parameters across various populations highlights their potential as reliable indicators in both medical practice and further CFD research, particularly in diverse human populations. Our findings suggest the potential applicability of dimensionless CFD parameters in analyzing nasal airflow, highlighting their utility across diverse demographic and geographic contexts. This research advances our understanding of nasal airflow dynamics and underscores the need for additional studies to validate these parameters in broader population cohorts. The approach of employing dimensionless parameters paves the way for future research that eliminates confounding size effects, enabling more accurate comparisons across different populations and sexes. The implications of this study are significant for the advancement of personalized medicine and the development of diagnostic tools that accommodate individual variations in nasal airflow.


  • Open Access

    Reducing variability in nasal surgery outcomes through computational fluid dynamics and advanced 3D virtual surgery techniques

    by M.A. Burgos, Lina Rosique, F. Piqueras, C. García-Navalón, M.A. Sevilla-García, D. Hellín, F. Esteban


  • Open Access

    Linking Chronic Otitis Media and Nasal Obstruction: A CFD Approach

    by Manuel A. Burgos, Alejandro Pardo, Rafael Rodríguez, Beatriz Rodríguez‐Balbuena, David Castro, Francisco Piqueras, Francisco Esteban

    Objectives: To investigate a possible relationship between altered nasal flow and chronic otitis media (COM) using computational fluid dynamics (CFD).Study Design: Retrospective case series.Methods: Retrospective cohort sample of CT scans from patients with COM and controls without COM to compare the results of various nasal airflow parameters determined by CFD between a group of patients with COM (N = 60) and a control group of subjects without any evidence of ear disease (N = 81).The CT were subjected to various procedures to carry out CFD studies, determining the resistance to nasal flow, the proportion of flow through the right and left nasal cavity, and two nondimensional estimators. The results of CFD studies between patients with COM and controls were compared.Results: Whereas only 12.3% of the controls had CFD alteration (10 out of 81), 43.3% of the patients suffering COM displayed alterations of our nondimensional parameters (26 out of 60).Conclusions: According to our results, the incidence of alterations in nasal airflow by studying with CFD is significantly higher in patients with COM than in controls. To our knowledge, this is the first article linking nasal cavity and COM using a CFD approach. Our results support the hypothesis that nasal flow alterations could be implicated in the etiopathogenesis of the COM.Level of Evidence: 4 Laryngoscope, 132:1224–1230, 2022


  • Open Access

    LINKING CHRONIC OTITIS MEDIA AND NASAL OBSTRUCTION: A CFD APPROACH

    by Manuel Antonio Burgos Olmos, Alejandro Antunez, Rafael Romero, Beatriz Balbuena, David Castro, Franscisco Piqueras Pérez, Francisco Esteban Ortega

    OBJECTIVES: To investigate a possible relationship between altered nasal flow and chronic otitis media (COM) using computational fluid dynamics (CFD). DESIGN: Retrospective cohort sample of CT scans from patients with COM and controls without COM to compare the results of various nasal airflow parameters determined by CFD between a group of patients with COM (N=60) and a control group of subjects without any evidence of ear disease (N=81). MAIN OUTCOME MEASURES: The CT were subjected to various procedures to carry out CFD studies, determining the resistance to nasal flow, the proportion of flow through the right and left nasal cavity, and two nondimentional estimators. The results of CFD studies between patients with COM and controls were compared. RESULTS AND CONCLUSIONS: Whereas only 12.3% of the controls had CFD alteration (10 out of 81), 43.3% of the patients suffering COM displayed alterations of our nondimentional parameters (26 out of 60). According to our results, the incidence of alterations in nasal airflow by studying with CFD is significantly higher in patients with COM than in controls IMPLICATIONS: To our knowledge, this is the first paper linking nasal cavity and COM using a CFD approach. Our results support the hypothesis that nasal flow alterations could be implicated in the etiopathogenesis of the COM.

  • Robust nondimensional estimators to assess the nasal airflow in health and disease

    by E. Sanmiguel‐Rojas, M. A. Burgos, C. del Pino, M. A. Sevilla‐García, F. Esteban‐Ortega

    There are significant variations of both human nose shapes and airflow patterns inside nasal cavities, so it is difficult to provide a comprehensive medical identification using a universal template for what otolaryngologists consider normal breathing at rest. In addition, airflow patterns present even more random characteristics in diseased nasal cavities. To give a medical assessment to differentiate the nasal cavities in health and disease, we propose 2 nondimensional estimators obtained from both medical images and computational fluid dynamics. The first mathematical estimator ϕ is a function of geometric features and potential asymmetries between nasal passages, while the second estimator R represents in fluid mechanics terms the total nasal resistance that corresponds to the atmosphere‐choana pressure drop. These estimators only require global information such as nasal geometry and magnitudes of flow determined by simulations under laminar conditions. We find that these estimators take low and high values for healthy and diseased nasal cavities, respectively. Our study, based on 24 healthy and 25 diseased Caucasian subjects, reveals that there is an interval of values associated with healthy cavities that clusters in a small region of the plane ϕ−R. Therefore, these estimators can be seen as a first approximation to provide nasal airflow data to the clinician in a noninvasive method, as the computed tomography scan that provides the required images is routinely obtained as a result of the preexisting naso‐sinusal condition.


  • New CFD tools to evaluate nasal airflow

    by M. A. Burgos, E. Sanmiguel-Rojas, C. del Pino, M. A. Sevilla-García, F. Esteban-Ortega

    Computational fluid dynamics (CFD) is a mathematical tool to analyse airflow. As currently CFD is not a usual tool for rhinologists, a group of engineers in collaboration with experts in Rhinology have developed a very intuitive CFD software. The program MECOMLAND® only required snapshots from the patient’s cross-sectional (tomographic) images, being the output those results originated by CFD, such as airflow distributions, velocity profiles, pressure, temperature, or wall shear stress. This is useful complementary information to cover diagnosis, prognosis, or follow-up of nasal pathologies based on quantitative magnitudes linked to airflow. In addition, the user-friendly environment NOSELAND® helps the medical assessment significantly in the post-processing phase with dynamic reports using a 3D endoscopic view. Specialists in Rhinology have been asked for a more intuitive, simple, powerful CFD software to offer more quality and precision in their work to evaluate the nasal airflow. We present MECOMLAND® and NOSELAND® which have all the expected characteristics to fulfil this demand and offer a proper assessment with the maximum of quality plus safety for the patient. These programs represent a non-invasive, low-cost (as the CT scan is already performed in every patient) alternative for the functional study of the difficult rhinologic case. To validate the software, we studied two groups of patients from the Ear Nose Throat clinic, a first group with normal noses and a second group presenting septal deviations. Wall shear stresses are lower in the cases of normal noses in comparison with those for septal deviation. Besides, velocity field distributions, pressure drop between nasopharynx and the ambient, and flow rates in each nostril were different among the nasal cavities in the two groups. These software modules open up a promising future to simulate the nasal airflow behaviour in virtual surgery intervention scenarios under different pressure or temperature conditions to understand the effects on nasal airflow.


  • Experimental study of rotating Hagen-Poiseuille flow discharging into a 1:8 sudden expansion

    by A. Miranda-Barea, B. Martínez-Arias, L. Parras, M. A. Burgos, C. del Pino

    In this paper, we present experimental evidence for the five different states that result from rotating Hagen-Poiseuille flow when it discharges into a 1:8 sudden expansion, namely: stable, convectively unstable, unstable shear layer, stable and unstable vortex breakdowns. Sanmiguel-Rojas et al. [“Three-dimensional structure of confined swirling jets at moderately large Reynolds numbers,” Phys. Fluids 20, 044104 (2008)] numerically predicted four of these five states and mapped the transition from one state to another. Our main objective is to study the onset of instabilities and vortex breakdown in these states experimentally. For this purpose, we visualize the flow at the inlet of the expansion for several values of moderately large Reynolds numbers, Re, and of swirl parameters, S. We analyze the inner region of the state that corresponds to the unstable shear layer in the sudden expansion and find two different states that share the same character, although they have different non-dimensional frequencies. The first relates to an oscillating structure near the axis, which arises at a small value of the swirl parameter, as well as to a generation of vortices that move downstream. The second shows, for greater values of the swirl parameter, vortices interacting with the boundary layer located on the wall of the static container that is perpendicular to the flow direction. In addition, we find a transition from stable to unstable vortex breakdown when perturbations become absolutely unstable inside the rotating pipe flow. Therefore, the most remarkable experimental finding is a new state, namely, unstable or transient vortex breakdown that takes place for the same pair of values (Rea, Sa) at which the onset of the absolute instability curve appears and intersects the region of stable vortex breakdown.