M. Naito
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
M. Naito has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
I. Asayama
Department of Orthopaedic Surgery, Fukuoka University School of Medicine, 7-45-1 Nanakuma, Jonan-ku, Fukuoka 814-0180, Japan Tel. +81-92-801-1011 ext. 3461; Fax +81-92-864-9055
1 shared publicationK. Ogata
Department of Orthopaedic Surgery, Fukuoka University School of Medicine, 7-45-1 Nanakuma, Jonan-ku, Fukuoka 814-0180, Japan Tel. +81-92-801-1011 ext. 3461; Fax +81-92-864-9055
1 shared publication
Latest Publications
- 9 March 1999
- Published by Springer Nature in International Orthopaedics
- Vol. 23 (1) , 31-33
Intraoperative limb length measurement in total hip arthroplasty
In order to evaluate the efficacy of intraoperative measurement of limb length inequality (LLI), we performed a prospective study on 64 patients who underwent unilateral total hip arthroplasty. The patients were divided into 2 groups. In Group I, the LLI was evaluated by the Shuck test, and in Group II by intraoperative measurement using a Steinman pin and an adjustable caliper. Preoperative LLIs assessed on radiographs averaged 1.18 cm in Group I and 0.37 cm in Group II. Pour évaluer l’efficacité de la mesure intra-opératoire de l’inégalité de la longueur d’un membre (ILM), nous avons effectué une étude prospective sur 42 patients qui ont subi une arthroplastie totale de la hanche unilatérale. Les patients furent divisés en 2 groupes selon la méthode particulière d’estimation intra-opératoire de ILM. ILM fut évalué par un essai de réduction dans le Groupe I et par une mesure intra-opératoire en utilisant une broche de Steinmann et un compas de calibrage ajustable dans le Groupe II. Sur les radiographies ILM intra-opératoires du Groupe I, la moyenne établie fut de 0,34 cm et pour le Groupe II de 0,41 cm. La moyenne établie de 1,15 cm dans le Groupe I et de 0,4 cm sur des radiographies ILM postopératoires a montré une différence significative entre les deux groupes.
- 9 March 1999
- Published by Springer Nature in International Orthopaedics
- Vol. 23 (1) , 31-33
Intraoperative limb length measurement in total hip arthroplasty
In order to evaluate the efficacy of intraoperative measurement of limb length inequality (LLI), we performed a prospective study on 64 patients who underwent unilateral total hip arthroplasty. The patients were divided into 2 groups. In Group I, the LLI was evaluated by the Shuck test, and in Group II by intraoperative measurement using a Steinman pin and an adjustable caliper. Preoperative LLIs assessed on radiographs averaged 1.18 cm in Group I and 0.37 cm in Group II. Pour évaluer l’efficacité de la mesure intra-opératoire de l’inégalité de la longueur d’un membre (ILM), nous avons effectué une étude prospective sur 42 patients qui ont subi une arthroplastie totale de la hanche unilatérale. Les patients furent divisés en 2 groupes selon la méthode particulière d’estimation intra-opératoire de ILM. ILM fut évalué par un essai de réduction dans le Groupe I et par une mesure intra-opératoire en utilisant une broche de Steinmann et un compas de calibrage ajustable dans le Groupe II. Sur les radiographies ILM intra-opératoires du Groupe I, la moyenne établie fut de 0,34 cm et pour le Groupe II de 0,41 cm. La moyenne établie de 1,15 cm dans le Groupe I et de 0,4 cm sur des radiographies ILM postopératoires a montré une différence significative entre les deux groupes.