AJAdeel Javed

Adeel Javed

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Adeel Javed has a total of 65 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Micro Gas Turbine Small-Scale Effects in Range Extended Electric Vehicles

    by Adeel Javed, Hassan Abdullah Khalid, Syed Umer bin Arif, Muhammad Imran, Ahmed Rezk, Zafar Ali Khan

    Application of a range extender in an electric vehicle can reduce the battery bank size and extend the driving range on a need basis. A micro gas turbine offers high power density, fuel flexibility, a reliable thermal efficiency (with recuperation), and less raw exhaust gaseous emissions compared to an internal combustion engine. However, micro gas turbines also incur low component performances due to small-scale effects related to high viscous losses, heat transfer between hot and cold sections, and manufacturing and assembly constraints compared to their larger counterparts. In this paper, the micro gas turbine thermodynamic cycle has been designed in Gas Turbine Simulation Program (GSP) and evaluated in terms of the small-scale effects simultaneously with the battery bank energy and charging time analysis. The key objective is to demonstrate the effectiveness of a micro gas turbine in saving the weight of a range-extended electric vehicle while understanding the impact of small-scale effects on the battery bank energy and charging time. Results indicate that a relatively smaller 22-kWh battery bank can be utilized with prospects of cost-savings together with a 47-kW micro gas turbine range extender to achieve an average driving range of 100 km and a charging time of 30 min for the baseline electric vehicle. Furthermore, the compressor and turbine isentropic efficiencies are found to have a significant impact on the overall battery bank performance.


  • Numerical investigation of non-uniform flow in twin-silo combustors and impact on axial turbine stage performance

    by Hafiz M Hassan, Adeel Javed, Asif H Khoja, Majid Ali, Muhammad B Sajid

    A clear understanding of the flow characteristics in the older generation of industrial gas turbines operating with silo combustors is important for potential upgrades. Non-uniformities in the form of circumferential and radial variations in internal flow properties can have a significant impact on the gas turbine stage performance and durability. This paper presents a comprehensive study of the underlying internal flow features involved in the advent of non-uniformities from twin-silo combustors and their propagation through a single axial turbine stage of the Siemens v94.2 industrial gas turbine. Results indicate the formation of strong vortical structures alongside large temperature, pressure, velocity, and flow angle deviations that are mostly located in the top and bottom sections of the turbine stage caused by the excessive flow turning in the upstream tandem silo combustors. A favorable validation of the simulated exhaust gas temperature (EGT) profile is also achieved via comparison with the measured data. A drop in isentropic efficiency and power output equivalent to 2.28% points and 2.1 MW, respectively is observed at baseload compared to an ideal straight hot gas path reference case. Furthermore, the analysis of internal flow topography identifies the underperforming turbine blading due to the upstream non-uniformities. The findings not only have implications for the turbine aerothermodynamic design, but also the combustor layout from a repowering perspective.


  • Design and CFD Analysis of Bladeless Ceiling Fan

    by Haseeb Aslam, Muhammad Zulqarnain Arif, Majid Ali, Adeel Javed

    Conventional ceiling fans use convective effect to distribute air to surroundings. The fan blades deflect the air downwards to produce a draft of air resulting in cooling of the room. However, this draft is delivered in form of gusts along with an uncomfortable noise induced by the blade-air interaction and resulting pressure fluctuations due to turbulence and unsteady flow phenomenon. Bladeless fans provide excellent solution in this regard. Bladeless fans are type of fans which do not contain visible blades or vanes. A motor rotor or radial impeller is used to direct flow inside the geometry of bladeless fan which is multiplied at outlet using Coanda effect. Currently, bladeless fans being used are of desk type providing sufficient air for one to two people. For air supply to the whole room, application of bladeless fan as a ceiling fan is studied in this paper. Bladeless fan is designed using Eppler 473 airfoil in SolidWorks. Flow of bladeless fan is simulated inside a room of dimensions $3.5\mathrm{m}\times 3.5\mathrm{m}$ room. Parametric analysis of bladeless fan is performed in ANSYS FLUENT to find optimum conditions at which bladeless fan yields maximum volumetric flow at outlet. Numerical model is validated by comparing numerical results to experimental model. Results showed that volumetric flow rate of bladeless ceiling fan increases with increase in fan to ceiling distance up to 0.3m and start decreasing as ceiling to fan distance increases beyond 0.3m. The volumetric flow rate of bladeless fan increases with increase in fan diameter and decreases with increase in nozzle diameter. Numerical results also showed that bladeless fans have similar outlet flow field as conventional ceiling fans with sufficient volumetric flow rate to be used as ceiling fans.


  • Open Access

    Impact Analysis of Large-Scale Wind Farms Integration in Weak Transmission Grid from Technical Perspectives

    by Shah Rukh Abbas, Syed Ali Abbas Kazmi, Muhammad Naqvi, Adeel Javed, Salman Raza Naqvi, Kafait Ullah, Tauseef-Ur-Rehman Khan, Dong Ryeol Shin

    The integration of commercial onshore large-scale wind farms into a national grid comes with several technical issues that predominately ensure power quality in accordance with respective grid codes. The resulting impacts are complemented with the absorption of larger amounts of reactive power by wind generators. In addition, seasonal variations and inter-farm wake effects further deteriorate the overall system performance and restrict the optimal use of available wind resources. This paper presented an assessment framework to address the power quality issues that have arisen after integrating large-scale wind farms into weak transmission grids, especially considering inter-farm wake effect, seasonal variations, reactive power depletion, and compensation with a variety of voltage-ampere reactive (Var) devices. Herein, we also proposed a recovery of significant active power deficits caused by the wake effect via increasing hub height of wind turbines. For large-scale wind energy penetration, a real case study was considered for three wind farms with a cumulative capacity of 154.4 MW integrated at a Nooriabad Grid in Pakistan to analyze their overall impacts. An actual test system was modeled in MATLAB Simulink for a composite analysis. Simulations were performed for various scenarios to consider wind intermittency, seasonal variations across four seasons, and wake effect. The capacitor banks and various flexible alternating current transmission systems (FACTS) devices were employed for a comparative analysis with and without considering the inter-farm wake effect. The power system parameters along with active and reactive power deficits were considered for comprehensive analysis. Unified power flow controller (UPFC) was found to be the best compensation device through comparative analysis, as it maintained voltage at nearly 1.002 pu, suppressed frequency transient in a range of 49.88–50.17 Hz, and avoided any resonance while maintaining power factors in an allowable range. Moreover, it also enhanced the power handling capability of the power system. The 20 m increase in hub height assisted the recovery of the active power deficit to 48%, which thus minimized the influence of the wake effect.


  • Thermal dry reforming of methane over La2O3 co-supported Ni/MgAl2O4 catalyst for hydrogen-rich syngas production

    by Asif Hussain Khoja, Mustafa Anwar, Sehar Shakir, Muhammad Taqi Mehran, Arslan Mazhar, Adeel Javed, Nor Aishah Saidina Amin


  • Open Access

    Effect of Modified Flow Schemes of Heat Transfer Fluid on the Performance of a Solar Absorption–Cooling System for an Educational Building in Pakistan

    by Iftikhar Bashir Butt, Jinwang Tan, Adeel Waqas, Majid Ali, Adeel Javed, Asfand Yar Ali

    Performance of solar absorption cooling systems (SACS) is the focus of contemporary studies for decreasing the electrical energy consumption of buildings as the conventional cooling system of buildings is the main consumer of electrical energy during the summer season in hot–humid climates. In this study, the performance analysis of SACS by manipulating different flow schemes to the heat transfer fluid between different components of the system was performed. TRNSYS model of SACS in an education building located at the city of Peshawar (34.00 N, 71.54 E), Pakistan to encounter the peak cooling load of 108 kW (during operating hours of the building i.e., 09 a.m. to 05 p.m.) is developed and all possible flow schemes of heat transfer fluid between the system’s components were compared. In Scheme-1 (S-1), a conventional flow pattern is used in which the hot water exiting from the chiller unit flows directly toward the stratified thermal storage unit. In Scheme-2 (S-2), the modified flow pattern of hot water exiting from the chiller unit will divert towards the auxiliary unit, if its temperature exceeds the temperature at the hot side outlet of the tank. Another modified flow pattern is Scheme-3 (S-3) in which the hot water leaving the chiller to keep diverting towards the auxiliary unit unless the outlet temperature from the hotter side of the tank would reach the minimum driving temperature (109 °C) of the chiller’s operation. Simulations in TRNSYS evaluates the SACS’s performance of all the schemes (conventional and modified) for the whole summer season and for each month. In general, S-3 with evacuated tube solar collector results in better primary energy saving with the smallest collector area per kilowatt for achieving 50% primary energy saving for the whole summer season.