Mohammad Bakhshipour
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mohammad Bakhshipour has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Farhad Namdari
Department of Engineering, Faculty of Environment, Science, and Economy, University of Exeter, Exeter EX4 4QF, UK
3 shared publications B. Rezaeealam
Electrical Engineering Department, Lorestan University, Khorramabad, Iran
1 shared publicationM. Sedaghat
Electrical Engineering Department, Lorestan University, Khorramabad, Iran
1 shared publicationMohammad Bagher Dolatshahi
Engineering Faculty Lorestan University Khorramabad Iran
1 shared publicationSajad Samadinasab
Department of Engineering, Faculty of Power Engineering, Lorestan University, Lorestan, Iran
1 shared publication
Latest Publications
- Open Access
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 20 (1)
Detecting False Data Injection in Smart Grid Overcurrent Relay Settings Using an AE–GAN–SVM Framework
Cybersecurity incidents in power grids have surged by over 60% in the past decade, revealing the vulnerability of protection layers to false data injection (FDI) attacks. Such attacks compromise phasor measurement units (PMUs) and overcurrent relays by altering measurement streams or relay configuration settings. This paper proposes a hybrid Autoencoder–Generative Adversarial Network–Support Vector Machine (AE–GAN–SVM) framework for online detection of coordinated FDI attacks in smart grid environments. The GAN generates realistic synthetic data under multiple fault and attack scenarios to mitigate dataset scarcity, while the autoencoder learns latent nonlinear representations from the augmented space. The resulting features are classified by an SVM to discriminate authentic from falsified samples. Unlike conventional techniques that isolate measurement‐ or setting‐level anomalies, the proposed method jointly monitors both domains, enabling robust cyber‐physical security coverage. Simulation results on the IEEE 14‐Bus test system demonstrate an average detection accuracy of 99.17%, outperforming existing approaches across various fault conditions—single‐phase‐to‐ground, double‐phase‐to‐ground, three‐phase‐to‐ground, double‐phase and three‐phase faults. The results confirm the model's capability to safeguard relay coordination integrity and enhance the cyber‐resilience of smart grid infrastructures.
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 20 (1)
Open AccessDetecting False Data Injection in Smart Grid Overcurrent Relay Settings Using an AE–GAN–SVM Framework
Cybersecurity incidents in power grids have surged by over 60% in the past decade, revealing the vulnerability of protection layers to false data injection (FDI) attacks. Such attacks compromise phasor measurement units (PMUs) and overcurrent relays by altering measurement streams or relay configuration settings. This paper proposes a hybrid Autoencoder–Generative Adversarial Network–Support Vector Machine (AE–GAN–SVM) framework for online detection of coordinated FDI attacks in smart grid environments. The GAN generates realistic synthetic data under multiple fault and attack scenarios to mitigate dataset scarcity, while the autoencoder learns latent nonlinear representations from the augmented space. The resulting features are classified by an SVM to discriminate authentic from falsified samples. Unlike conventional techniques that isolate measurement‐ or setting‐level anomalies, the proposed method jointly monitors both domains, enabling robust cyber‐physical security coverage. Simulation results on the IEEE 14‐Bus test system demonstrate an average detection accuracy of 99.17%, outperforming existing approaches across various fault conditions—single‐phase‐to‐ground, double‐phase‐to‐ground, three‐phase‐to‐ground, double‐phase and three‐phase faults. The results confirm the model's capability to safeguard relay coordination integrity and enhance the cyber‐resilience of smart grid infrastructures.
- Open Access
- 13 September 2024
- Published by Springer Nature in Iranian Journal of Science and Technology, Transactions of Electrical Engineering
- Vol. 48 (4) , 1685-1695
Setting-Less Differential Protection of Power Transformers Based on Wavelet Transform
This paper presents a novel algorithm for power transformer differential protection based on wavelet transform (WT) and introduces new indices to distinguish internal faults from normal operating conditions and the occurrence of the inrush current. The proposed setting-less algorithm has no limits on the structure, dimension, capacity, and core type of the transformer. For this purpose, six indices based on fault detection functions extracted from WT transform are presented. Then, weighting factors for the indices by using the least squares method are calculated. In order to validate the proposed method, the approach has been evaluated on four transformers with 2 kVA, 10 kVA, 400 kVA, and 125 MVA. The success rate of fault detection in 10 kVA, and 125 MVA transformers was 100% and in 2 kVA and 400 kVA transformers was 93.33% and 94.44%, respectively. Also, the proposed algorithm has a remarkable capability in fast fault detection to protect the power transformer.
- 13 September 2024
- Published by Springer Nature in Iranian Journal of Science and Technology, Transactions of Electrical Engineering
- Vol. 48 (4) , 1685-1695
Open AccessSetting-Less Differential Protection of Power Transformers Based on Wavelet Transform
This paper presents a novel algorithm for power transformer differential protection based on wavelet transform (WT) and introduces new indices to distinguish internal faults from normal operating conditions and the occurrence of the inrush current. The proposed setting-less algorithm has no limits on the structure, dimension, capacity, and core type of the transformer. For this purpose, six indices based on fault detection functions extracted from WT transform are presented. Then, weighting factors for the indices by using the least squares method are calculated. In order to validate the proposed method, the approach has been evaluated on four transformers with 2 kVA, 10 kVA, 400 kVA, and 125 MVA. The success rate of fault detection in 10 kVA, and 125 MVA transformers was 100% and in 2 kVA and 400 kVA transformers was 93.33% and 94.44%, respectively. Also, the proposed algorithm has a remarkable capability in fast fault detection to protect the power transformer.
- 12 February 2021
- Published by Springer Nature in Electrical Engineering
- Vol. 103 (5) , 2243-2257
Optimal coordination of overcurrent relays with constraining communication links using DE–GA algorithm
- 12 February 2021
- Published by Springer Nature in Electrical Engineering
- Vol. 103 (5) , 2243-2257
Optimal coordination of overcurrent relays with constraining communication links using DE–GA algorithm