Mohideen Salihu Farook
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mohideen Salihu Farook has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
Hany Mohamed Aly Ahmed
Department of Restorative Dentistry, Faculty of Dentistry, Universiti Malaya, Kuala Lumpur, Malaysia
3 shared publications- Okba Mahmoud
Clinical Science Department, Ajman University, Ajman, United Arab Emirates
3 shared publications - Saaid Al Shehadat
Department of Restorative Dentistry, College of Dental Medicine University of Sharjah Sharjah UAE
3 shared publications Erum Zain
Faculty of Dentistry, Department of Restorative Dentistry SEGi University Selangor Malaysia
2 shared publications- Mohamed Ahmed Elsayed
Department of Endodontics, RAK College of Dental Sciences, RAK Medical and Health Sciences University, Ras Al-Khaimah, United Arab Emirates
2 shared publications Mohamed Shady Nabhan
Department of Prosthetic Dentistry, Faculty of Dentistry, Ain Shams University, Cairo, Egypt
2 shared publications
Latest Publications
- Open Access
- 17 August 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Evaluation of root and its canal morphological variations in mandibular premolars in Malaysian subpopulation using a novel classification system: a CBCT study
- 17 August 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessEvaluation of root and its canal morphological variations in mandibular premolars in Malaysian subpopulation using a novel classification system: a CBCT study
- 3 July 2026
- Published by Wiley in European Journal of Dental Education
Are Antibiotic Prescribing Patterns for Endodontic Infections Among Undergraduate Dental Students Consistent With Current Guidelines? A Multinational Cross‐Sectional Study
Aim: Appropriate antibiotic prescribing is a core competency in dental education. This study evaluated dental students' knowledge, antibiotic selection patterns, and adherence to international guidelines for the management of endodontic infections. Materials and Methods: An online survey was administered to students in their final two clinical years across 19 countries. Three clinical scenarios were evaluated: first‐line antibiotic choice, second‐line when the first choice is ineffective, and drug of choice for penicillin‐allergic patients. Participants reported drug, dose, frequency, and duration. Guideline adherence was quantified using a 0–5 scoring system based on European Society of Endodontology and American Association of Endodontists recommendations. Mixed‐effects linear regression models with country as a random effect were used to identify predictors of guideline‐concordant prescribing. Results: A total of 4226 responses were analysed. Amoxicillin was the most frequently selected first‐line antibiotic (57.6%), followed by amoxicillin–clavulanic acid (18.4%), with marked between‐country variation; adjusted first‐choice concordance was highest in Colombia (4.57) and lowest in Bangladesh (2.49). For second‐line therapy, amoxicillin–clavulanic acid predominated (33.2%), with the highest adherence in Ecuador (3.40) and the lowest in Switzerland (2.15). In penicillin‐allergic patients, clindamycin was most commonly selected (47.8%), but allergy‐specific concordance varied widely, ranging from 3.52 in Colombia to 1.06 in India. Age positively predicted second‐line concordance, while lower allergy‐specific concordance was observed among second‐year students and males. Conclusions: Marked variability and frequent deviations from guideline‐recommended prescribing highlight persistent educational gaps. Strengthening antimicrobial stewardship training within undergraduate dental curricula is warranted.
- 3 July 2026
- Published by Wiley in European Journal of Dental Education
Are Antibiotic Prescribing Patterns for Endodontic Infections Among Undergraduate Dental Students Consistent With Current Guidelines? A Multinational Cross‐Sectional Study
Aim: Appropriate antibiotic prescribing is a core competency in dental education. This study evaluated dental students' knowledge, antibiotic selection patterns, and adherence to international guidelines for the management of endodontic infections. Materials and Methods: An online survey was administered to students in their final two clinical years across 19 countries. Three clinical scenarios were evaluated: first‐line antibiotic choice, second‐line when the first choice is ineffective, and drug of choice for penicillin‐allergic patients. Participants reported drug, dose, frequency, and duration. Guideline adherence was quantified using a 0–5 scoring system based on European Society of Endodontology and American Association of Endodontists recommendations. Mixed‐effects linear regression models with country as a random effect were used to identify predictors of guideline‐concordant prescribing. Results: A total of 4226 responses were analysed. Amoxicillin was the most frequently selected first‐line antibiotic (57.6%), followed by amoxicillin–clavulanic acid (18.4%), with marked between‐country variation; adjusted first‐choice concordance was highest in Colombia (4.57) and lowest in Bangladesh (2.49). For second‐line therapy, amoxicillin–clavulanic acid predominated (33.2%), with the highest adherence in Ecuador (3.40) and the lowest in Switzerland (2.15). In penicillin‐allergic patients, clindamycin was most commonly selected (47.8%), but allergy‐specific concordance varied widely, ranging from 3.52 in Colombia to 1.06 in India. Age positively predicted second‐line concordance, while lower allergy‐specific concordance was observed among second‐year students and males. Conclusions: Marked variability and frequent deviations from guideline‐recommended prescribing highlight persistent educational gaps. Strengthening antimicrobial stewardship training within undergraduate dental curricula is warranted.
- 26 May 2026
- Published by Wiley in European Journal of Dental Education
Students' Feedback on Two Systems to Classify Root Canal Morphology: A Survey Across Dental Schools in the United Arab Emirates
Introduction: The purpose of the study was to compare students' feedback on the accuracy, practicability, understanding, and the application of the two systems to classify root canal morphology in the UAE dental schools. Materials and Methods: This survey‐based study involved 4th and 5th year undergraduate students and dental trainees from four dental schools in the UAE. The study was conducted in two phases. In phase one, a PowerPoint presentation describing the two systems (Vertucci and Ahmed et al.) to classify root canal morphology was delivered physically to the students at three separate sessions in each dental school ( n = 12). In phase II, a printed questionnaire was distributed to collect their feedback. Fisher's Exact Test was used for statistical analysis and p ‐value was set at 0.05. Results: Out of 1024 individuals across the four dental schools, 707 (69%) participated in the study. The students and the trainees agreed that the Ahmed et al. system is more accurate (90.1%), more practical (84.6%), and improved the understanding of root canal morphology (91.5%). In addition, they recommended incorporating in the curriculum (91.4%) for teaching preclinical and clinical courses (92.1%). No significant differences ( p > 0.05) were found in the feedback between the students and the dental trainees for all the five closed‐ended questions. Conclusion: The majority of the undergraduate students across the four dental schools in the UAE had agreed that the Ahmed et al. system is more accurate and practical compared to the Vertucci system, and they recommended its adoption in the dental curriculum.
- 26 May 2026
- Published by Wiley in European Journal of Dental Education
Students' Feedback on Two Systems to Classify Root Canal Morphology: A Survey Across Dental Schools in the United Arab Emirates
Introduction: The purpose of the study was to compare students' feedback on the accuracy, practicability, understanding, and the application of the two systems to classify root canal morphology in the UAE dental schools. Materials and Methods: This survey‐based study involved 4th and 5th year undergraduate students and dental trainees from four dental schools in the UAE. The study was conducted in two phases. In phase one, a PowerPoint presentation describing the two systems (Vertucci and Ahmed et al.) to classify root canal morphology was delivered physically to the students at three separate sessions in each dental school ( n = 12). In phase II, a printed questionnaire was distributed to collect their feedback. Fisher's Exact Test was used for statistical analysis and p ‐value was set at 0.05. Results: Out of 1024 individuals across the four dental schools, 707 (69%) participated in the study. The students and the trainees agreed that the Ahmed et al. system is more accurate (90.1%), more practical (84.6%), and improved the understanding of root canal morphology (91.5%). In addition, they recommended incorporating in the curriculum (91.4%) for teaching preclinical and clinical courses (92.1%). No significant differences ( p > 0.05) were found in the feedback between the students and the dental trainees for all the five closed‐ended questions. Conclusion: The majority of the undergraduate students across the four dental schools in the UAE had agreed that the Ahmed et al. system is more accurate and practical compared to the Vertucci system, and they recommended its adoption in the dental curriculum.
- 9 January 2026
- Published by Elsevier in The Journal of the American Dental Association
- Vol. 157 (6) , 629-638
Evaluation of cutting efficiency, surface roughness, and diameter of diamond rotary instruments on laboratory and computer-aided designed and computer-aided manufactured resin composite materials
- 9 January 2026
- Published by Elsevier in The Journal of the American Dental Association
- Vol. 157 (6) , 629-638
Evaluation of cutting efficiency, surface roughness, and diameter of diamond rotary instruments on laboratory and computer-aided designed and computer-aided manufactured resin composite materials
- 13 August 2025
- Published by Springer Nature
- p. 1-15
Teledentistry: Potential Applications and Challenges
- 13 August 2025
- Published by Springer Nature
- p. 1-15
Teledentistry: Potential Applications and Challenges
- Open Access
- 7 April 2025
- Published by Springer Nature in BMC Oral Health
- Vol. 25 (1) , 1-10
Micro-computed tomography analysis and ex-vivo detection of six root canals in a four-rooted mandibular first premolar
Mandibular first premolar teeth show a wide range of root and canal anatomical variations including accessory roots, deep root proximal grooves and multiple canals. This study provides qualitative and quantitative morphological analysis of a rare four-rooted mandibular first premolar scanned using micro-CT. In addition, it provides clinical implications through endodontic access cavity preparation and negotiation of canals under dental operating microscope (DOM) to assess the difficulty for locating the canals. An extracted four-rooted mandibular first premolar tooth sample was subjected to 2D radiographic imaging in two views and micro-computed tomography (micro-CT) scanning with a resolution of 25 μm. Subsequently, 3D- reconstruction of the tooth sample was performed using Mimics software (Materialise, Leuven, Belgium). 3D (volume and surface area) and 2D measurements (distances between orifices, area, perimeter, maximum and minimum diameter, roundness, aspect ratio and form factor) were obtained. In addition, endodontic access was prepared, and the canals were explored under the DOM. Location of the canals were confirmed by periapical radiographs with the aid of hand files. The 2D imaging showed the presence of four canals. Micro-CT analysis showed a complex canal anatomy which was classified using Ahmed et al. coding system as 444 MB1–2–1–2 DB2-1-2-1-3-2-3 1(ML1 DL1). Quantitative analysis showed that the MB root had the highest canal volume and surface area compared to other canals. The 2D measurements showed wide variations among canals, which reflects the complexity of the canals in terms of size and geometry. The MB and DB canals tend to have more aspect ratio values (more oval/flattened) than other canals. After access cavity preparation and exploration, six root canals were identified [mesio-buccal one (MB1), mesio-buccal two (MB2), disto-buccal (DB), mesio-lingual (ML), disto-lingual (DL) and lingual disto-buccal (LDB)]. The canals in the MB root showed two locations of splitting. Mandibular first premolars may have complex variations in the number of roots and canal configurations. The different anatomical presentations demonstrated in the 2D and 3D measurements of the six canals presented in this report signifies the anatomical variabilities, which could complicate the detection and negotiation of canals during root canal treatment. Ahmed et al. coding system is useful in classifying teeth with complex root and canal anatomy.
- 7 April 2025
- Published by Springer Nature in BMC Oral Health
- Vol. 25 (1) , 1-10
Open AccessMicro-computed tomography analysis and ex-vivo detection of six root canals in a four-rooted mandibular first premolar
Mandibular first premolar teeth show a wide range of root and canal anatomical variations including accessory roots, deep root proximal grooves and multiple canals. This study provides qualitative and quantitative morphological analysis of a rare four-rooted mandibular first premolar scanned using micro-CT. In addition, it provides clinical implications through endodontic access cavity preparation and negotiation of canals under dental operating microscope (DOM) to assess the difficulty for locating the canals. An extracted four-rooted mandibular first premolar tooth sample was subjected to 2D radiographic imaging in two views and micro-computed tomography (micro-CT) scanning with a resolution of 25 μm. Subsequently, 3D- reconstruction of the tooth sample was performed using Mimics software (Materialise, Leuven, Belgium). 3D (volume and surface area) and 2D measurements (distances between orifices, area, perimeter, maximum and minimum diameter, roundness, aspect ratio and form factor) were obtained. In addition, endodontic access was prepared, and the canals were explored under the DOM. Location of the canals were confirmed by periapical radiographs with the aid of hand files. The 2D imaging showed the presence of four canals. Micro-CT analysis showed a complex canal anatomy which was classified using Ahmed et al. coding system as 444 MB1–2–1–2 DB2-1-2-1-3-2-3 1(ML1 DL1). Quantitative analysis showed that the MB root had the highest canal volume and surface area compared to other canals. The 2D measurements showed wide variations among canals, which reflects the complexity of the canals in terms of size and geometry. The MB and DB canals tend to have more aspect ratio values (more oval/flattened) than other canals. After access cavity preparation and exploration, six root canals were identified [mesio-buccal one (MB1), mesio-buccal two (MB2), disto-buccal (DB), mesio-lingual (ML), disto-lingual (DL) and lingual disto-buccal (LDB)]. The canals in the MB root showed two locations of splitting. Mandibular first premolars may have complex variations in the number of roots and canal configurations. The different anatomical presentations demonstrated in the 2D and 3D measurements of the six canals presented in this report signifies the anatomical variabilities, which could complicate the detection and negotiation of canals during root canal treatment. Ahmed et al. coding system is useful in classifying teeth with complex root and canal anatomy.
- Open Access
- 1 January 2022
- Published by Wiley in International Journal of Dentistry
- Vol. 2022 (1) , 6480047
Morphological and Chemical Analysis of Different Types of Calcium Silicate‐Based Cements
Objectives. Particle size and shape can influence the properties of materials. However, to improve the physicochemical and biological properties of mineral trioxide aggregate (MTA), silicate‐based hydraulic cements were introduced. This study aimed to evaluate and compare the major constituents and crystalline structures along with the surface morphology of different types of calcium silicate‐based cement (CSC). Materials and Methods. Six different types of CSC (white Portland cement, white ProRoot MTA, white MTA Angelus, Biodentine, and Endosequence, both putty and paste) were used in this study. Five samples of each material were analyzed in both uncured and cured cement using scanning electron microscopy/energy‐dispersive X‐ray (SEM/EDX), X‐ray diffraction (XRD), and Fourier transform‐infrared spectroscopy (FTIR). Results. SEM analysis showed that the surfaces of all materials consisted of particle sizes ranging from 0.194 μm to approximately 51.82 μm. The basic elements found in both uncured and cured cement of all tested materials using EDX were carbon, calcium, silicon, and oxygen. A difference was observed in the presence or absence of magnesium, aluminum, bismuth, zirconium, and tantalum. XRD showed that all tested materials were composed mainly of tricalcium silicate and dicalcium silicate, which are the main components of Portland cement. FTIR analysis showed aromatic rings, phosphine PH, alkyl halides, and alcohol O‐H groups in all tested materials but at different wavenumbers. Conclusions. The different types of CSCs tested in this study were primarily modified types of Portland cement with the addition of radiopacifiers. ProRoot MTA and MTA Angelus contained bismuth oxide, Biodentine contains zirconium oxide, whereas Endosequence root repair materials (both putty and paste) contained zirconium oxide and tantalum oxide. Endosequence root repair materials showed smaller particle sizes than the other groups. White PC had the most irregular and large particle sizes. CSC had a smaller particle size, except for MTA Angelus. Clinical Relevance. The composition of CSC has a direct influence on the properties of these cements, which may affect the clinical outcome of the treatment.
- 1 January 2022
- Published by Wiley in International Journal of Dentistry
- Vol. 2022 (1) , 6480047
Open AccessMorphological and Chemical Analysis of Different Types of Calcium Silicate‐Based Cements
Objectives. Particle size and shape can influence the properties of materials. However, to improve the physicochemical and biological properties of mineral trioxide aggregate (MTA), silicate‐based hydraulic cements were introduced. This study aimed to evaluate and compare the major constituents and crystalline structures along with the surface morphology of different types of calcium silicate‐based cement (CSC). Materials and Methods. Six different types of CSC (white Portland cement, white ProRoot MTA, white MTA Angelus, Biodentine, and Endosequence, both putty and paste) were used in this study. Five samples of each material were analyzed in both uncured and cured cement using scanning electron microscopy/energy‐dispersive X‐ray (SEM/EDX), X‐ray diffraction (XRD), and Fourier transform‐infrared spectroscopy (FTIR). Results. SEM analysis showed that the surfaces of all materials consisted of particle sizes ranging from 0.194 μm to approximately 51.82 μm. The basic elements found in both uncured and cured cement of all tested materials using EDX were carbon, calcium, silicon, and oxygen. A difference was observed in the presence or absence of magnesium, aluminum, bismuth, zirconium, and tantalum. XRD showed that all tested materials were composed mainly of tricalcium silicate and dicalcium silicate, which are the main components of Portland cement. FTIR analysis showed aromatic rings, phosphine PH, alkyl halides, and alcohol O‐H groups in all tested materials but at different wavenumbers. Conclusions. The different types of CSCs tested in this study were primarily modified types of Portland cement with the addition of radiopacifiers. ProRoot MTA and MTA Angelus contained bismuth oxide, Biodentine contains zirconium oxide, whereas Endosequence root repair materials (both putty and paste) contained zirconium oxide and tantalum oxide. Endosequence root repair materials showed smaller particle sizes than the other groups. White PC had the most irregular and large particle sizes. CSC had a smaller particle size, except for MTA Angelus. Clinical Relevance. The composition of CSC has a direct influence on the properties of these cements, which may affect the clinical outcome of the treatment.
- Open Access
- 1 January 2021
- Published by Wiley in BioMed Research International
- Vol. 2021 (1)
Comparing the Effectiveness of Different Dentinal Desensitizing Agents: In Vitro Study
Objectives. To evaluate the in vitro effectiveness of desensitizing agents in reducing dentine permeability. Methods. The efficacy of desensitizing agents in reducing dentine permeability by occluding dentine tubules was evaluated using a fluid filtration device that conducts at 100 cmH2O (1.4 psi) pressure, and SEM/EDX analyses were evaluated and compared. Forty‐two dentine discs (n = 42) of 1 ± 0.2 mm width were obtained from caries‐free permanent human molars. Thirty dentine discs (n = 30) were randomly divided into 3 groups (n = 10): Group 1: 2.7% wt. monopotassium‐monohydrogen oxalate (Mp‐Mh oxalate), Group 2: RMGI XT VAR, and Group 3: LIQ SiO2. Dentine permeability was measured following treatment application after 10 minutes, storage in artificial saliva after 10 minutes and 7 days, and citric acid challenge for 3 minutes. Data were analysed with a repeated measures ANOVA test. Dentine discs (n = 12) were used for SEM/EDX analyses to acquire data on morphological changes on dentine surface and its mineral content after different stages of treatment. Results. Desensitizing agents’ application on the demineralized dentine discs exhibited significant reduction of permeability compared to its maximum acid permeability values. Mp‐Mh oxalate showed a significant reduction in dentine permeability (p < 0.05) when compared to RMGI XT VAR and LIQ SiO2. On SEM/EDX analysis, all the agents formed mineral precipitates that occluded the dentine tubules. Conclusions. 2.7% wt. monopotassium‐monohydrogen oxalate was significantly effective in reducing dentine permeability compared to RMGI XT VAR and LIQ SiO2.
- 1 January 2021
- Published by Wiley in BioMed Research International
- Vol. 2021 (1)
Open AccessComparing the Effectiveness of Different Dentinal Desensitizing Agents: In Vitro Study
Objectives. To evaluate the in vitro effectiveness of desensitizing agents in reducing dentine permeability. Methods. The efficacy of desensitizing agents in reducing dentine permeability by occluding dentine tubules was evaluated using a fluid filtration device that conducts at 100 cmH2O (1.4 psi) pressure, and SEM/EDX analyses were evaluated and compared. Forty‐two dentine discs (n = 42) of 1 ± 0.2 mm width were obtained from caries‐free permanent human molars. Thirty dentine discs (n = 30) were randomly divided into 3 groups (n = 10): Group 1: 2.7% wt. monopotassium‐monohydrogen oxalate (Mp‐Mh oxalate), Group 2: RMGI XT VAR, and Group 3: LIQ SiO2. Dentine permeability was measured following treatment application after 10 minutes, storage in artificial saliva after 10 minutes and 7 days, and citric acid challenge for 3 minutes. Data were analysed with a repeated measures ANOVA test. Dentine discs (n = 12) were used for SEM/EDX analyses to acquire data on morphological changes on dentine surface and its mineral content after different stages of treatment. Results. Desensitizing agents’ application on the demineralized dentine discs exhibited significant reduction of permeability compared to its maximum acid permeability values. Mp‐Mh oxalate showed a significant reduction in dentine permeability (p < 0.05) when compared to RMGI XT VAR and LIQ SiO2. On SEM/EDX analysis, all the agents formed mineral precipitates that occluded the dentine tubules. Conclusions. 2.7% wt. monopotassium‐monohydrogen oxalate was significantly effective in reducing dentine permeability compared to RMGI XT VAR and LIQ SiO2.
- Open Access
- 1 June 2016
- Published by Elsevier in Desalination and Water Treatment
- Vol. 57 (26) , 11999-12009
Natural radioactivity levels in commercialized bottled drinking water and their radiological quality assessment
This work presents radiological data on most commonly sold bottled water brands in the urban areas of Bangladesh. A significant fragment of the population use bottled water as their source of daily water intake. It is known from the literature that some varieties of bottled waters contain natural radionuclides in higher concentration than the traditional municipal tap water. In this study, concentrations of naturally occurring radioactive materials, particularly 226Ra, 228Ra, and 40K, and its annual effective dose with its stochastic effects were determined in available brands of bottled mineral water manufactured in Bangladesh. The measurement was performed by gamma-ray spectroscopy using a hyper-pure germanium detector. The activity concentration of the radiologically important nuclides 226Ra and 228Ra were found within the permissible limits of 1 and 0.1 Bq l−1, respectively, recommended by World Health Organization (WHO) in almost all samples. The annual effective doses caused by natural radioactivity of 228Ra for the infants (0–1 year) and adolescent (12–17 year) groups exceeded the recommended WHO guideline level of 0.1 mSv y−1 for drinking water in most of the cases. Particularly for those age groups, the estimated doses are extremely high. In general, the carcinogenic risk due to natural radioactive doses for all bottled water samples were found below the acceptable limit of 10−3.
- 1 June 2016
- Published by Elsevier in Desalination and Water Treatment
- Vol. 57 (26) , 11999-12009
Open AccessNatural radioactivity levels in commercialized bottled drinking water and their radiological quality assessment
This work presents radiological data on most commonly sold bottled water brands in the urban areas of Bangladesh. A significant fragment of the population use bottled water as their source of daily water intake. It is known from the literature that some varieties of bottled waters contain natural radionuclides in higher concentration than the traditional municipal tap water. In this study, concentrations of naturally occurring radioactive materials, particularly 226Ra, 228Ra, and 40K, and its annual effective dose with its stochastic effects were determined in available brands of bottled mineral water manufactured in Bangladesh. The measurement was performed by gamma-ray spectroscopy using a hyper-pure germanium detector. The activity concentration of the radiologically important nuclides 226Ra and 228Ra were found within the permissible limits of 1 and 0.1 Bq l−1, respectively, recommended by World Health Organization (WHO) in almost all samples. The annual effective doses caused by natural radioactivity of 228Ra for the infants (0–1 year) and adolescent (12–17 year) groups exceeded the recommended WHO guideline level of 0.1 mSv y−1 for drinking water in most of the cases. Particularly for those age groups, the estimated doses are extremely high. In general, the carcinogenic risk due to natural radioactive doses for all bottled water samples were found below the acceptable limit of 10−3.