OTOren M. Tepper

Oren M. Tepper

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Oren M. Tepper has a total of 61 co-authors. Here are the top co-authors by number of shared publications:

  • Carrie S. Stern

    Division of Plastic and Reconstructive Surgery, Memorial Sloan Kettering Cancer Center

    9 shared publications
  • Elizabeth B. Jelks

    New York, N.Y.

    6 shared publications
  • Glenn W. Jelks

    New York, N.Y.

    6 shared publications
  • Evan S. Garfein

    Division of Plastic and Reconstructive Surgery, Montefiore Medical Center, Bronx, New York, United States

    5 shared publications
  • Evan S. Garfein

    From the Division of Plastic and Reconstructive Surgery and Department of Radiology, Montefiore Medical Center, Albert Einstein College of Medicine; and Montefiore 3D Printing and Innovation Laboratory

    4 shared publications
  • Jillian E. Schreiber

    Division of Plastic and Reconstructive Surgery, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, New York, USA

    4 shared publications

Latest Publications

  • Open Access

    Challenges in the Management of a Calvarial Defect in an NF1-Patient

    by Imane Abbas, Jinan Behnan, Abhishek Dubey, Genesis Liriano, Oren Tepper, Andrew J. Kobets

    Background: Calvarial defects in NF1 are rare and lack standardized management guidelines. This study seeks to shed light on calvarial defects in NF1 patients with extensive skull erosion. Methods: This case report focuses on clinical and radiological presentations and surgical interventions during six years of follow-up, comparing the results with those in the literature. Results: A five-year-old female with NF1 disease was diagnosed with a spontaneous calvarial defect in the occipital region and an arachnoid cyst underneath. The lesion enlarged progressively over the years and at the age of nine, she underwent her first surgery. Our surgery team performed a cranioplasty using a split-thickness bone graft harvested from the parietal bone after cyst decompression. Two years later, she underwent revision surgery with a titanium mesh plate due to total resorption of the initial bone graft and unsuccessful closure of the large defect. Conclusions: Calvaria defects are a relatively unknown aspect of NF1, and no standard treatment exists. Their management requires a personalized approach, considering factors like lesion size, and the potential for multiple interventions throughout the patient’s lifetime. Due to their progressive nature and the possibility of additional lesions, long-term follow-up is crucial for effective monitoring and intervention planning.


  • Turning Back the Clock with Lip Lift: Quantifying Perceived Age Reduction Using Artificial Intelligence

    by Alexandra R. Gordon, Jillian E. Schreiber, Sofia C. Tortora, Stephany Ferreira, Robert G. Dorfman, Sean Sadaat, Jason Roostaeian, Jonathan B. Levine, Oren M. Tepper

    Facial Plastic Surgery & Aesthetic Medicine


  • Open Access

    Comparing Postoperative Taping vs Customized 3D Splints for Managing Nasal Edema after Rhinoplasty

    by Anmol Patel, Alexandra N. Bs Townsend, Alexandra R. Gordon, Jillian S. Schreiber, Oren M. Tepper, John Do Layke

    Background: Significant swelling after rhinoplasty can temporarily obscure results and lead to distress for patients and surgeons. We recently developed three dimensional (3D)-printed nasal splints that aim to protect the nose and limit edema by applying gentle compression. This prospective, randomized study compares postoperative nasal edema in patients being treated with traditional taping versus 3D-printed splints. Methods: Patients undergoing primary rhinoplasty (2019–2020) were randomized into two groups: taping versus 3D-printed splinting. For 12 weeks, patients either applied steri-strips to the dorsum and tip, or used 3D-printed splints, which were based on nasal simulations. The percentage change in volume (cm3) was calculated for the total nose, dorsum, and nasal tip at various time points. Results: Nasal taping (n = 34) demonstrated a volume reduction of 4.8%, 9.9%, 10.0%, 10.3%, and 10.6% (compared with baseline) at 2 weeks, 6 weeks, 3 months, 6 months, and 1 year, respectively. In contrast, the resolution of swelling with 3D splints (n = 36) was 5.0%, 8.6%, 11.0%, 14.9%, and 15.1% at the same time points. Inter-group comparison showed that 3D splints led to significantly less edema of the total nose at 6 months and 1 year (P ≤ 0.05), as well as consistent reductions in the tip and dorsum, specifically (1 year, P ≤ 0.1, 0.01, respectively). Conclusions: 3D-printed splints after rhinoplasty leads to a significant reduction of edema, most noticeable at 6 months and 1 year. This study suggests that customized 3D-printed splints offer an effective clinical alternative to traditional taping to reduce postoperative edema after rhinoplasty.


  • Commentary on: The Management of Lumps, Bumps, and Contour Irregularities of the Lower Eyelid and Cheek After Poor Outcome Fat Transfer

    by Alexandra N Townsend, Oren M Tepper

    Alexandra N Townsend, BS, Oren M Tepper, MD; Commentary on: The Management of Lumps, Bumps, and Contour Irregularities (LBCs) of the Lower Eyelid and Cheek Afte


  • Open Access

    Current Trends in Ideal Nasal Aesthetics Show Younger Patients Have a Preference Toward Longer Augmented Noses

    by Anmol A Patel, Alexandra R Gordon, Alexandra N Townsend, Jinesh Shah, Evan S Garfein, Oren M Tepper

    Aesthetic norms fluctuate over time and often result in generational differences in preferred ideal nasal aesthetics. While some traditional concepts of the ideal nasal aesthetic have been suggested in our literature, there has been no study to date that has identified contemporary preferences across different age groups. To understand the general population's current perception of ideal nasal profiles. Two-dimensional images of female noses (n = 10) of varying ethnicities were simulated to alter either the radix height or nasolabial angle (NLA) independently. Radix height was manipulated by increasing or decreasing the height by 5 mm relative to baseline. For NLA, 3 images were created with the following measurements: (1) 90°, (2) 100°, and (3) 110°. Groups were categorized by generation and age at the time of completing the study: Generation Z (Gen Z; age 18-23), Millennial 20s (age 24-30), Millennial 30s (age 31-39), and Generation X (Gen X; age 40-55). Each figure consisted of either 3 variations in radix height (n = 10) or 3 variations in NLA (n = 10). Within each figure, volunteers were asked to choose their preferred nose. The younger generations, Gen Z and Millennial 20s and 30s, preferred a more augmented radix compared to Gen X which preferred a baseline radix height. Gen Z, Millennial 20s, and Gen X preferred a 90° NLA, while Millennial 30s preferred an NLA of 100°. The authors found that younger populations (Gen Z, Millennial 20s, and Millennial 30s) preferred a more augmented appearance to the nasal radix and, on average, a more acute NLA than published data suggest.


  • Three-Dimensional Perioral Assessment Following Subnasal Lip Lift

    by Anmol A Patel, Jillian E Schreiber, Alexandra R Gordon, Karan Mehta, Brian D Mikolasko, Jonathan B Levine, Oren M Tepper

    The sub-nasal lip lift is a surgical technique that elevates the “lip line” (interface between vertical maxillary incisor height and upper lip) to achieve a more youthful aesthetic. This study offers the first ever definition of 3D changes to the upper lip due to sub-nasal lip lift. A lip lift procedure was performed (on cadaveric samples) in a sequential manner from 2.5mm to 5.0mm intervals (n=13). 3D photographs were taken using the VECTRA H1 system (Canfield Scientific, Fairfield, NJ), and 3D analysis was performed including vermillion height and width, philtral height, sagittal lip projection, vermillion surface area, and incisor show. A subset of samples (n=9) underwent a modification of the technique by undermining of the upper lip subcutaneous tissue off of the underlying muscular fascia. Vermillion surface area (baseline ranged from 1.45 - 5.52 cm 2) increased by an average of 20.5% and 43.1% with 2.5 mm and 5.0 mm lip lift, respectively. Anterior projection of the vermillion increased in all cases by an average of 2.13mm and 4.07 mm at 2.5 and 5.0 mm respectively. Philtral height decreased in all cases by an average of 3.37 and 7.23 mm at 2.5 and 5.0 mm, whereas incisal show increased on average of 1.9 and 4.09 mm, respectively. This study is the first to define the 3D morphometric changes to the upper lip following sub-nasal lip lift. Quantifying these changes aids the surgeon in both preoperative planning and guiding patient expectations.


  • Intraoperative Navigation in Plastic Surgery with Augmented Reality: A Preclinical Validation Study

    by Hayeem L. Rudy, Jillian S. Schreiber, Nicole Wake, Robert P. B.A. Lesko, Alexandra B.A. Gordon, Evan S. Garfein, Oren M. Tepper

    Background: Augmented reality allows users to visualize and interact with digital images including three-dimensional holograms in the real world. This technology may have value intraoperatively by improving surgical decision-making and precision but relies on the ability to accurately align a hologram to a patient. This study aims to quantify the accuracy with which a hologram of soft tissue can be aligned to a patient and used to guide intervention. Methods: A mannequin’s face was marked in a standardized fashion with 14 incision patterns in red and nine reference points in blue. A three-dimensional photograph was then taken, converted into a hologram, and uploaded to HoloLens (Verto Studio LLC, San Diego, Calif.), a wearable augmented reality device. The red markings were then erased, leaving only the blue points. The hologram was then viewed through the HoloLens in augmented reality and aligned onto the mannequin. The user then traced the overlaid red markings present on the hologram. Three-dimensional photographs of the newly marked mannequin were then taken and compared with the baseline three-dimensional photographs of the mannequin for accuracy of the red markings. This process was repeated for 15 trials (n = 15). Results: The accuracy of the augmented reality-guided intervention, when considering all trials, was 1.35 ± 0.24 mm. Markings that were positioned laterally on the face were significantly more difficult to reproduce than those centered around the facial midline. Conclusions: Holographic markings can be accurately translated onto a mannequin with an average error of less than 1.4 mm. These data support the notion that augmented reality navigation may be practical and reliable for clinical integration in plastic surgery.


  • Commentary on: The Layered Anatomy of the Nose: An Ultrasound-Based Investigation

    by Oren M Tepper, Alexa Choy

    Oren M Tepper, MD, Alexa Choy; Commentary on: The Layered Anatomy of the Nose: An Ultrasound-Based Investigation, Aesthetic Surgery Journal, , sjab378, https://


  • 3D Printed Surgical Guides Applied in Rhinoplasty to Help Obtain Ideal Nasal Profile

    by Alexandra R. Gordon, Jillian E. Schreiber, Anmol Patel, Oren M. Tepper

    Introduction As computer simulation for rhinoplasty continues to rise, the technology’s utility extends beyond increasing patient conversion. Virtual simulation of the surgical result can assist with surgical planning and intraoperative decision-making. 3D printed anatomic models or surgical guides based on 3D images may help align surgeons with their original surgical plan. This study aims to evaluate the utility of 3D printed surgical guides as an intraoperative tool to help establish dorsal height and tip position. Methods Patients undergoing rhinoplasty had preoperative virtual 3D surgical simulations performed. Simulations were used to create a 3D printed nasal kits containing ceramic models of the preoperative nose and simulated nose, sagittal contour guide, and customized postoperative nasal splint. Nasal guides were sterilized for continual intraoperative assessment of profile contour (i.e., dorsal height and tip position). Postoperative 3D images (1–3 months post-op) were then compared to preoperative simulations. The difference between z coordinates and y coordinates determined the difference in projection and rotation, respectively. Results Fifteen patients met inclusion criteria for this study. With the use of 3D printed surgical guides, the final tip position was on average of 0.8±0.7mm from simulated projection and 0.3±0.2mm from simulated rotation. Similarly, projection for the cartilaginous and bony dorsum was within 1.0±0.8 and 0.8±0.7mm of the simulation, respectively. Conclusion Virtual simulation is useful in defining aesthetic goals preoperatively, but the potential clinical value extends beyond this. 3D printed rhinoplasty guides extend the simulation’s utility to decision-making intraoperatively. This technology offers a novel medium for anatomic reference, which may improve adherence to desired aesthetic goals. Level of Evidence V This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine Ratings, please refer to Table of Contents or online Instructions to Authors www.springer.com/00266.