Vidhi Himanshu Sheth
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Vidhi Himanshu Sheth has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Naisargi Shah
Professor and Head of Department, Department of Prosthodontics and Crown & Bridge, T.P.C.T.'s Terna Dental College, Navi Mumbai, India
4 shared publications Naisargi P. Shah
Department of Prosthodontics, Crown and Bridge, TPCT's Terna Dental College, Navi Mumbai, Maharashtra, India
3 shared publicationsNikhil Bhanushali
Reader, Department of Public Health Dentistry, T.P.C.T.'s Terna Dental College, Navi Mumbai, India
3 shared publications- Anshul Khanna2 shared publications
Ashutosh Pai
2 shared publicationsRomi Jain
Professor and Head of Department, Department of Public Health Dentistry, T.P.C.T.'s Terna Dental College, Navi Mumbai, India
2 shared publications
Latest Publications
- 30 October 2025
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 135 (3) , 647-648
Comments regarding: Sheth et al. Development and validation of a risk-of-bias tool for assessing in vitro studies conducted in dentistry: The QUIN
- 30 October 2025
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 135 (3) , 647-648
Comments regarding: Sheth et al. Development and validation of a risk-of-bias tool for assessing in vitro studies conducted in dentistry: The QUIN
- Open Access
- 24 January 2024
- Published by Wolters Kluwer Health in The Journal of Indian Prosthodontic Society
- Vol. 24 (1) , 95-102
A comparative evaluation of internal and marginal fits of custom post and core fabricated using conventional and two digital techniques: An in vitro study
Aim: The purpose of this in vitro study was to comparatively evaluate the marginal and internal fits of cobalt–chromium metal custom post and core fabricated using a conventional technique with two digital techniques. Settings and Design: The study was designed in an in-vitro study setting. Materials and Methods: Five sets of custom post and core restorations were fabricated using the conventional (Group 1) and two semi digital methods (digital scanning of the resin pattern and computer aided additive manufacturing, and digital scanning of the silicone impression and subsequent computer aided designing [CAD] computer aided manufacturing fabrication) (Group 2 and 3). Marginal and internal fits of the posts were evaluated using a micro computed tomography scan at various points. Statistical Analysis Used: A one way ANOVA test of the scores was made to evaluate the effect of different methods of custom post and core fabrication on marginal and internal fits. Bonferroni adjusted post hoc tests were conducted for intergroup comparison. Results: Least marginal gap was reported in Group 3 (82.5 ± 14.36 μm) followed by Group 1 (110 ± 25.19 μm) and Group 2 (112.5 ± 26.75 μm). Least internal gap at cervical, middle and apical as well as overall values were observed in Group 3 (78 ± 9.25 μm, 72 ± 7.79 μm, 160 ± 15.81 μm, 103.3 ± 4.43 μm) followed by Group 1 (113.5 ± 25.35 μm, 132.5 ± 19.92 μm, 502 ± 74.63 μm, 249.3 ± 25.44 μm) and Group 2 (114.5 ± 21.68 μm, 133.5 ± 19.57 μm, 598 ± 87.86 μm, 282 ± 28.91 μm) respectively. The results of one-way ANOVA and Bonferroni adjusted post hoc tests for marginal gap did not show any statistically significant difference between the three groups ( P > 0.05) but revealed statistically significant difference ( P = 0.02) in internal gap values at the cervical, middle, and apical regions as well as overall internal gap region between the three groups. Conclusions: Better marginal and internal fits were observed in custom post and core fabricated by digital scanning of the silicone impression and subsequent CAD as compared to those fabricated by the other two groups.
- 24 January 2024
- Published by Wolters Kluwer Health in The Journal of Indian Prosthodontic Society
- Vol. 24 (1) , 95-102
Open AccessA comparative evaluation of internal and marginal fits of custom post and core fabricated using conventional and two digital techniques: An in vitro study
Aim: The purpose of this in vitro study was to comparatively evaluate the marginal and internal fits of cobalt–chromium metal custom post and core fabricated using a conventional technique with two digital techniques. Settings and Design: The study was designed in an in-vitro study setting. Materials and Methods: Five sets of custom post and core restorations were fabricated using the conventional (Group 1) and two semi digital methods (digital scanning of the resin pattern and computer aided additive manufacturing, and digital scanning of the silicone impression and subsequent computer aided designing [CAD] computer aided manufacturing fabrication) (Group 2 and 3). Marginal and internal fits of the posts were evaluated using a micro computed tomography scan at various points. Statistical Analysis Used: A one way ANOVA test of the scores was made to evaluate the effect of different methods of custom post and core fabrication on marginal and internal fits. Bonferroni adjusted post hoc tests were conducted for intergroup comparison. Results: Least marginal gap was reported in Group 3 (82.5 ± 14.36 μm) followed by Group 1 (110 ± 25.19 μm) and Group 2 (112.5 ± 26.75 μm). Least internal gap at cervical, middle and apical as well as overall values were observed in Group 3 (78 ± 9.25 μm, 72 ± 7.79 μm, 160 ± 15.81 μm, 103.3 ± 4.43 μm) followed by Group 1 (113.5 ± 25.35 μm, 132.5 ± 19.92 μm, 502 ± 74.63 μm, 249.3 ± 25.44 μm) and Group 2 (114.5 ± 21.68 μm, 133.5 ± 19.57 μm, 598 ± 87.86 μm, 282 ± 28.91 μm) respectively. The results of one-way ANOVA and Bonferroni adjusted post hoc tests for marginal gap did not show any statistically significant difference between the three groups ( P > 0.05) but revealed statistically significant difference ( P = 0.02) in internal gap values at the cervical, middle, and apical regions as well as overall internal gap region between the three groups. Conclusions: Better marginal and internal fits were observed in custom post and core fabricated by digital scanning of the silicone impression and subsequent CAD as compared to those fabricated by the other two groups.
- 1 January 2024
- Published by Indian Prosthodontic Society, Kerala State Branch in The Journal of Prosthetic and Implant Dentistry
- Vol. 7 (2)
An evaluation of the sources and extent of error in the position of implants placed using 3D-printed stereolithographic surgical guides.
Official website of Indian Prosthodontic Society Kerala State Branch
- 1 January 2024
- Published by Indian Prosthodontic Society, Kerala State Branch in The Journal of Prosthetic and Implant Dentistry
- Vol. 7 (2)
An evaluation of the sources and extent of error in the position of implants placed using 3D-printed stereolithographic surgical guides.
Official website of Indian Prosthodontic Society Kerala State Branch
- 1 January 2024
- Published by Indian Prosthodontic Society, Kerala State Branch in The Journal of Prosthetic and Implant Dentistry
- Vol. 7 (2)
An evaluation of the sources and extent of error in the position of implants placed using 3D-printed stereolithographic surgical guides.
Official website of Indian Prosthodontic Society Kerala State Branch
- 1 January 2024
- Published by Indian Prosthodontic Society, Kerala State Branch in The Journal of Prosthetic and Implant Dentistry
- Vol. 7 (2)
An evaluation of the sources and extent of error in the position of implants placed using 3D-printed stereolithographic surgical guides.
Official website of Indian Prosthodontic Society Kerala State Branch
- 1 September 2022
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 128 (3) , 436-442
An evaluation of virtually planned and 3D-printed stereolithographic surgical guides from CBCT and digital scans: An in vitro study
- 1 September 2022
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 128 (3) , 436-442
An evaluation of virtually planned and 3D-printed stereolithographic surgical guides from CBCT and digital scans: An in vitro study
- Top Cited Papers
- 23 June 2022
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 131 (6) , 1038-1042
Development and validation of a risk-of-bias tool for assessing in vitro studies conducted in dentistry: The QUIN
- 23 June 2022
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 131 (6) , 1038-1042
Top Cited PapersDevelopment and validation of a risk-of-bias tool for assessing in vitro studies conducted in dentistry: The QUIN