NKNicholas Kaufmann

Nicholas Kaufmann

*This is an algorithmically generated author record based on publicly available information.

Nicholas Kaufmann has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Load monitoring concept for tidal turbines based on strain measurements at the support arm of the vessel

    by Urs Zweiffel, Georg Jacobs, Julian Röder, Tim Scholz, Maximilian Zweiffel, Nicholas Kaufmann

    Tidal turbines show predictable energy output. Thus, this form of energy generation has potential to supplement established, but less predictable, renewable energy systems like PV and wind energy. However, the levelized cost of electricity (LCOE) of tidal energy is roughly ten times higher than those of solar and wind energy. Therefore, the LCOE must be reduced to ascertain economic competitiveness. A high share of the LCOE consists of the maintenance costs. Thus, decreasing the maintenance costs is an effective way to reduce the LCOE. The current lack of monitoring systems necessitates a time-based maintenance schedule. Compared to predictive maintenance systems, this results in premature and sometimes unnecessary service. The application of a load monitoring system and corresponding maintenance plans allows to maintain the turbines based on the loads experienced, reducing not needed service and therefore maintenance costs. A novel concept for a load monitoring system for tidal turbines based on strain measurements has been developed. The considered tidal turbine system consists of a support arm structure which is attached to a floating vessel. The strains are measured with strain gauges attached to the bespoken support arm structure. To reduce effects of the environmental conditions, strains are measured on the arm above sea level and not at the rotor. Measuring the strains on the support arm distant from the rotor necessitates a robust transfer function to determine the rotor loads. In this paper, the development and optimization of the transfer function is presented. FEM simulations are used to determine the strains on the arm for varying static rotor loads. The simulation results are used to derive a transfer function from arm strain to rotor loads. The transfer function with strain measurements on the support arm in the field as an input comprises a real-time capable load monitoring system. To develop a cheap but reliable system, the number of measuring points of the system needs to be minimized, while still achieving a robust transfer function. The influence of the strain gauge’s measuring range is also considered for the robustness of the transfer function. An optimization algorithm is used to find the minimal amount of measuring points for a 1 % relative error between applied and measured load. The layout is optimized regarding the condition of the transfer function to mispositioning and misalignment measuring points.

  • Open Access

    Impact of cavitation and inflow perturbation on the performance of a horizontal-axis tidal turbine

    by Alessandro Capone, Fabio DiFelice, Francesco Salvatore, Harish Maddukkari, Nicholas Kaufmann, Ralf Starzmann

    The impact of cavitation and inflow perturbation by an upstream support structure on the performance of a horizontal-axis tidal turbine has been studied by experiments at model scale in a depressurized water channel at CNR-INM. Measurements of turbine generated power and thrust have been carried out at varying channel flow speed, tip-speed ratio, and cavitation number. The visualization of cavitation patterns has been associated with the performance measurements to identify the role played by different cavitation types on turbine behavior. Radiated noise measurement were also performed to assess the impact of cavitation phenomena on turbine induced acoustic signature.


  • Open Access

    Using vortex generators for flow separation control on tidal turbine profiles and blades

    by M. Manolesos, L. Chng, N. Kaufmann, P. Ouro, D. Ntouras, G. Papadakis


  • Open Access

    Effect of Fouling on the Performance of an Instream Turbine

    by Ralf Starzmann, Nicholas Kaufmann, Penny Jeffcoate, Ray Pieroway, Maricarmen Guerra, Alex Hay

    As the tidal energy industry starts to mature towards commercial projects a key focus is on reliable power performance. As for any marine application, fouling poses a potential performance reduction risk for instream turbine deployments. SCHOTTEL HYDRO have developed their current commercial SCHOTTEL Instream Turbines. Four drivetrains with 6.3m rotors were deployed on the surface platform PLAT-I by Sustainable Marine Energy. One of PLAT-Is key features is access to the turbines for inspection and maintenance in situ. The system has undergone sea testing from 2017 to 2021 in Scotland and Nova Scotia (Canada). This paper presents the hydrodynamic rotor performance reduction due to fouling based on full-scale experimental results. An in-house blade element momentum model is used to quantify the changes of the hydrodynamic forces in terms of lift and drag for the hydrofoils used. Furthermore, the effect of fouling on the downstream wake was quantified in the field. The performance reduction due to fouling is significant and leads to a power drop of up to 43%, whereas the thrust is reduced by 25%. This is also reflected in a reduction of the turbine’s downstream wake as a “fouled” rotor extracts less energy from the flow. Modifications of the polar data, used for semi-empirical performance predictions, are able to predict the effect of fouling on the rotor performance. In general, the results derived from the testing prove the significance of access to the turbines in order to avoid reduction in the turbines’ performance due to fouling.


  • Open Access

    Strain gauge measurements on a full scale tidal turbine blade

    by Thomas Lake, Jack Hughes, Michael Togneri, Alison J. Williams, Penny Jeffcoate, Ralf Starzmann, Nicholas Kaufmann, Ian Masters