Changcheng Shi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Changcheng Shi has a total of 138 co-authors. Here are the top co-authors by number of shared publications:
- Guokun Zuo
Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo, Zhejiang, China
14 shared publications Huilin Zhou
Zhejiang International Scientific and Technological Cooperative Base of Biomedical Materials and Technology Zhejiang Engineering Research Center for Biomedical Materials Laboratory of Advanced Theranostic Materials and Technology Ningbo Institute of Materials Technology and Engineering Chinese Academy of Sciences Ningbo People's Republic of China
6 shared publicationsYehao Ma
Laboratory of Advanced Theranostic Materials and Technology, Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo, 315201, China; Ningbo Cixi Institute of Biomedical Engineering, Ningbo, 315300, China; Robotics Institute, Ningbo University of Technology, Ningbo 315211, China
6 shared publicationsDazheng Zhao
Laboratory of Advanced Theranostic Materials and Technology, Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo, 315201, China; Ningbo Cixi Institute of Biomedical Engineering, Ningbo, 315300, China
5 shared publicationsLiang Tao
Department of Neurorehabilitation, Ningbo Rehabilitation Hospital, Ningbo, 315040, China
5 shared publicationsSijia Ye
Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo, China
4 shared publications
Latest Publications
Bioinspired Epidermal Electrode With Excellent Environmental Tolerance and Adhesion for Robust Electrophysiological Monitoring
Flexible epidermal electrodes often suffer from performance degradation under harsh conditions, such as high humidity, low temperature, and accelerated aging. Drawing inspiration from the bicontinuous structure of coral reef exoskeletons, we developed a bio‐mimetic conformal dry electrode (CGAg@PUA) that integrates a highly conductive skeleton with an adhesive matrix. Gravity‐driven self‐deposition of silver nanoparticles (AgNPs) on the lower electrode surface creates planar bicontinuous conductive paths. The PUA matrix, featuring polydimethylsiloxane soft segments, offers superior elasticity, adhesion, and low‐temperature resistance. Additionally, carbon nanofibers (CNFs) and graphene (GR) dispersed in the matrix establish continuous 3D conductive pathways. CGAg@PUA exhibited excellent cytocompatibility and biological safety in cytotoxicity assessments. After 24 h of accelerated aging, the CGAg@PUA‐20 electrode retained 57.3 ± 6.3% of its initial adhesion strength and 75.5 ± 4.8% of its tensile strength on non‐degreased porcine skin. The in situ adhesion strength on non‐degreased porcine skin reached 566.2 ± 32.4 kPa at −80°C. At 10 Hz, the skin interface impedance of the CGAg@PUA‐20 electrode was 91.4 ± 5.2 kΩ·cm 2 , while after immersion in deionized water for 24 h, the impedance decreased by 6%. At last, the CGAg@PUA electrode demonstrates stable, prolonged capability to acquire high‐quality electrocardiogram (ECG), electromyography (EMG), and electroencephalogram (EEG) signals.
Bioinspired Epidermal Electrode With Excellent Environmental Tolerance and Adhesion for Robust Electrophysiological Monitoring
Flexible epidermal electrodes often suffer from performance degradation under harsh conditions, such as high humidity, low temperature, and accelerated aging. Drawing inspiration from the bicontinuous structure of coral reef exoskeletons, we developed a bio‐mimetic conformal dry electrode (CGAg@PUA) that integrates a highly conductive skeleton with an adhesive matrix. Gravity‐driven self‐deposition of silver nanoparticles (AgNPs) on the lower electrode surface creates planar bicontinuous conductive paths. The PUA matrix, featuring polydimethylsiloxane soft segments, offers superior elasticity, adhesion, and low‐temperature resistance. Additionally, carbon nanofibers (CNFs) and graphene (GR) dispersed in the matrix establish continuous 3D conductive pathways. CGAg@PUA exhibited excellent cytocompatibility and biological safety in cytotoxicity assessments. After 24 h of accelerated aging, the CGAg@PUA‐20 electrode retained 57.3 ± 6.3% of its initial adhesion strength and 75.5 ± 4.8% of its tensile strength on non‐degreased porcine skin. The in situ adhesion strength on non‐degreased porcine skin reached 566.2 ± 32.4 kPa at −80°C. At 10 Hz, the skin interface impedance of the CGAg@PUA‐20 electrode was 91.4 ± 5.2 kΩ·cm 2 , while after immersion in deionized water for 24 h, the impedance decreased by 6%. At last, the CGAg@PUA electrode demonstrates stable, prolonged capability to acquire high‐quality electrocardiogram (ECG), electromyography (EMG), and electroencephalogram (EEG) signals.
- Open Access
- 21 November 2025
- Published by Elsevier in Acta Psychologica
- Vol. 261, 105951
Motor learning improvement by matching visual-haptic error modulation to individual skill level and motivation
- 21 November 2025
- Published by Elsevier in Acta Psychologica
- Vol. 261, 105951
Open AccessMotor learning improvement by matching visual-haptic error modulation to individual skill level and motivation
- 24 October 2025
- Published by Springer Nature
- p. 336-347
Effects of Rhythmic Auditory Cues on Brain Network Characterization During Human Gait Initiation
- 24 October 2025
- Published by Springer Nature
- p. 336-347
Effects of Rhythmic Auditory Cues on Brain Network Characterization During Human Gait Initiation
- 5 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (18) , 29258-29270
A Modified Method of Wearable Gait Analysis for Stroke Patients Based on the Peak Width Threshold and Phase Re-Segmentation
Wearable gait analysis technology offering flexibility and cost-effectiveness, holds significant potential for quantifying the gait functions of stroke patients. It remains a key challenge that how to further reduce cumulative errors by using wearable technology. An algorithm for re-segmenting the gait phase was proposed to improve the precision of zero-velocity detection and gait parameters. The adaptive threshold method was used to separate the stationary phase and the non-stationary phase of the gait cycle. Next, an efficient method called the peak width threshold (PWT) for phase re-segmentation was developed to obtain effective peaks from acceleration and angular velocity data. And the peaks which were incorrectly segmented would be adjusted between the stationary and non-stationary phase. The precision of feet position detection was improved by using zero velocity update (ZUPT) algorithm and dual-foot constraints. Finally, four typical gait parameters were calculated from feet position and phase information. The results demonstrated that the wearable inertial sensors system displays a good agreement compared to the foot pressure-based gait analysis system, and the mean absolute errors (MAE) of the stride length, step length, stride velocity, and cadence are 1.77±1.22 cm, 2.40±1.83 cm, 0.02±0.01 m/s, and 1.16±1.37 steps/min, respectively. This proposed method improves the accuracy of gait phase and feet position detection, which is helpful to objectively evaluate the gait functions of stroke patients.
- 5 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (18) , 29258-29270
A Modified Method of Wearable Gait Analysis for Stroke Patients Based on the Peak Width Threshold and Phase Re-Segmentation
Wearable gait analysis technology offering flexibility and cost-effectiveness, holds significant potential for quantifying the gait functions of stroke patients. It remains a key challenge that how to further reduce cumulative errors by using wearable technology. An algorithm for re-segmenting the gait phase was proposed to improve the precision of zero-velocity detection and gait parameters. The adaptive threshold method was used to separate the stationary phase and the non-stationary phase of the gait cycle. Next, an efficient method called the peak width threshold (PWT) for phase re-segmentation was developed to obtain effective peaks from acceleration and angular velocity data. And the peaks which were incorrectly segmented would be adjusted between the stationary and non-stationary phase. The precision of feet position detection was improved by using zero velocity update (ZUPT) algorithm and dual-foot constraints. Finally, four typical gait parameters were calculated from feet position and phase information. The results demonstrated that the wearable inertial sensors system displays a good agreement compared to the foot pressure-based gait analysis system, and the mean absolute errors (MAE) of the stride length, step length, stride velocity, and cadence are 1.77±1.22 cm, 2.40±1.83 cm, 0.02±0.01 m/s, and 1.16±1.37 steps/min, respectively. This proposed method improves the accuracy of gait phase and feet position detection, which is helpful to objectively evaluate the gait functions of stroke patients.
- Open Access
- 17 April 2024
- Published by Frontiers Media SA in Frontiers in Neurology
- Vol. 15, 1337230
Upper limb motor assessment for stroke with force, muscle activation and interhemispheric balance indices based on sEMG and fNIRS
Introduction: Upper limb rehabilitation assessment plays a pivotal role in the recovery process of stroke patients. The current clinical assessment tools often rely on subjective judgments of healthcare professionals. Some existing research studies have utilized physiological signals for quantitative assessments. However, most studies used single index to assess the motor functions of upper limb. The fusion of surface electromyography (sEMG) and functional near-infrared spectroscopy (fNIRS) presents an innovative approach, offering simultaneous insights into the central and peripheral nervous systems.Methods: We concurrently collected sEMG signals and brain hemodynamic signals during bilateral elbow flexion in 15 stroke patients with subacute and chronic stages and 15 healthy control subjects. The sEMG signals were analyzed to obtain muscle synergy based indexes including synergy stability index (SSI), closeness of individual vector (CV) and closeness of time profile (CT). The fNIRS signals were calculated to extract laterality index (LI).Results: The primary findings were that CV, SSI and LI in posterior motor cortex (PMC) and primary motor cortex (M1) on the affected hemisphere of stroke patients were significantly lower than those in the control group (p < 0.05). Moreover, CV, SSI and LI in PMC were also significantly different between affected and unaffected upper limb movements (p < 0.05). Furthermore, a linear regression model was used to predict the value of the Fugl-Meyer score of upper limb (FMul) (R2 = 0.860, p < 0.001).Discussion: This study established a linear regression model using force, CV, and LI features to predict FMul scale values, which suggests that the combination of force, sEMG and fNIRS hold promise as a novel method for assessing stroke rehabilitation.
- 17 April 2024
- Published by Frontiers Media SA in Frontiers in Neurology
- Vol. 15, 1337230
Open AccessUpper limb motor assessment for stroke with force, muscle activation and interhemispheric balance indices based on sEMG and fNIRS
Introduction: Upper limb rehabilitation assessment plays a pivotal role in the recovery process of stroke patients. The current clinical assessment tools often rely on subjective judgments of healthcare professionals. Some existing research studies have utilized physiological signals for quantitative assessments. However, most studies used single index to assess the motor functions of upper limb. The fusion of surface electromyography (sEMG) and functional near-infrared spectroscopy (fNIRS) presents an innovative approach, offering simultaneous insights into the central and peripheral nervous systems.Methods: We concurrently collected sEMG signals and brain hemodynamic signals during bilateral elbow flexion in 15 stroke patients with subacute and chronic stages and 15 healthy control subjects. The sEMG signals were analyzed to obtain muscle synergy based indexes including synergy stability index (SSI), closeness of individual vector (CV) and closeness of time profile (CT). The fNIRS signals were calculated to extract laterality index (LI).Results: The primary findings were that CV, SSI and LI in posterior motor cortex (PMC) and primary motor cortex (M1) on the affected hemisphere of stroke patients were significantly lower than those in the control group (p < 0.05). Moreover, CV, SSI and LI in PMC were also significantly different between affected and unaffected upper limb movements (p < 0.05). Furthermore, a linear regression model was used to predict the value of the Fugl-Meyer score of upper limb (FMul) (R2 = 0.860, p < 0.001).Discussion: This study established a linear regression model using force, CV, and LI features to predict FMul scale values, which suggests that the combination of force, sEMG and fNIRS hold promise as a novel method for assessing stroke rehabilitation.
- 25 February 2024
- Vol. 41 (1) , 90-97
基于交互力模糊识别的上肢康复机器人模式调整控制策略研究
在上肢康复机器人辅助训练过程中,对于软瘫期脑卒中患者通常采用被动训练策略。为了激发患者的主动康复意愿,对于逐渐具备主动发力能力的患者,康复治疗师会采用机器人助动训练策略。本文针对末端牵引式上肢康复机器人,提出一种基于交互力模糊判别的人体上肢运动功能评估方法以及按需辅助的人机交互控制策略。首先设计了基于计算力矩控制器的被动训练和结合势能场的助动训练模式,然后将训练过程中三维力传感器采集的交互力信息引入至模糊推理系统中,提出了主动参与度 σ ,并设计相应的辅助策略算法实现两种训练模式的自适应调整。最后通过试验证明了主动参与度 σ 与表面肌电信号之间的相关性。并且,相较于仅通过交互力大小进行模式调整的控制策略,该方法具有更快的响应速度,使机器人在训练过程中更具安全性。
- 25 February 2024
- Vol. 41 (1) , 90-97
基于交互力模糊识别的上肢康复机器人模式调整控制策略研究
在上肢康复机器人辅助训练过程中,对于软瘫期脑卒中患者通常采用被动训练策略。为了激发患者的主动康复意愿,对于逐渐具备主动发力能力的患者,康复治疗师会采用机器人助动训练策略。本文针对末端牵引式上肢康复机器人,提出一种基于交互力模糊判别的人体上肢运动功能评估方法以及按需辅助的人机交互控制策略。首先设计了基于计算力矩控制器的被动训练和结合势能场的助动训练模式,然后将训练过程中三维力传感器采集的交互力信息引入至模糊推理系统中,提出了主动参与度 σ ,并设计相应的辅助策略算法实现两种训练模式的自适应调整。最后通过试验证明了主动参与度 σ 与表面肌电信号之间的相关性。并且,相较于仅通过交互力大小进行模式调整的控制策略,该方法具有更快的响应速度,使机器人在训练过程中更具安全性。
- 20 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (7) , 2265-2275
Short Step Length Estimation for Parkinson's Disease Patients by Using Fusion Data From Camera-IMU in Smart Glasses
Shortened step length is a prominent motor abnormality in Parkinson's disease (PD) patients. Current methods for estimating short step length have the limitation of relying on laboratory scenarios, wearing multiple sensors, and inaccurate estimation results from a single sensor. In this paper, we proposed a novel method for estimating short step length for PD patients by fusing data from camera and inertial measurement units in smart glasses. A simultaneous localization and mapping technique and acceleration thresholding-based step detection technique were combined to realize the step length estimation. Two sets of experiments were conducted to demonstrate the performance of our method. In the first set of experiments with 12 healthy subjects, the proposed method demonstrated an average error of 8.44% across all experiments including six fixed step lengths below 30 cm. The second set of straightly walking experiments were implemented with 12 PD patients, the proposed method exhibited an average error of 4.27% compared to a standard gait evaluation technique in total walking distance. Notably, among the results of step lengths below 40 cm, our method agreed with the standard technique (R ${^{2}}$ =0.8659). This study offers a promising approach for estimating short step length for PD patients during smart glasses-based gait training.
- 20 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (7) , 2265-2275
Short Step Length Estimation for Parkinson's Disease Patients by Using Fusion Data From Camera-IMU in Smart Glasses
Shortened step length is a prominent motor abnormality in Parkinson's disease (PD) patients. Current methods for estimating short step length have the limitation of relying on laboratory scenarios, wearing multiple sensors, and inaccurate estimation results from a single sensor. In this paper, we proposed a novel method for estimating short step length for PD patients by fusing data from camera and inertial measurement units in smart glasses. A simultaneous localization and mapping technique and acceleration thresholding-based step detection technique were combined to realize the step length estimation. Two sets of experiments were conducted to demonstrate the performance of our method. In the first set of experiments with 12 healthy subjects, the proposed method demonstrated an average error of 8.44% across all experiments including six fixed step lengths below 30 cm. The second set of straightly walking experiments were implemented with 12 PD patients, the proposed method exhibited an average error of 4.27% compared to a standard gait evaluation technique in total walking distance. Notably, among the results of step lengths below 40 cm, our method agreed with the standard technique (R ${^{2}}$ =0.8659). This study offers a promising approach for estimating short step length for PD patients during smart glasses-based gait training.
- Open Access
- 12 February 2024
- Published by Frontiers Media SA in Frontiers in Human Neuroscience
- Vol. 18, 1337504
Effects of rhythmic visual cues on cortical activation and functional connectivity features during stepping: an fNIRS study
Introduction: Rhythmic visual cues (RVCs) may influence gait initiation by modulating cognition resources. However, it is unknown how RVCs modulate cognitive resources allocation during gait movements. This study focused on investigating the effects of RVCs on cortical hemodynamic response features during stepping to evaluate the changes of cognitive resources.Methods: We recorded cerebral hemoglobin concentration changes of 14 channels in 17 healthy subjects using functional near-infrared spectroscopy (fNIRS) during stepping tasks under exposure to RVCs and non-rhythmic visual cues (NRVCs). We reported mean oxygenated hemoglobin (HbO) concentration changes, β-values, and functional connectivity (FC) between channels.Results: The results showed that, the RVC conditions revealed lower HbO responses compared to the NRVC conditions during the preparation and early stepping. Correspondingly, the β-values reflected that RVCs elicited lower hemodynamic responses than NRVCs, and there was a decreasing trend in stimulus-evoked cortical activation as the task progressed. However, the FC between channels were stronger under RVCs than under NRVCs during the stepping progress, and there were more significant differences in FC during the early stepping.Discussion: In conclusion, there were lower cognitive demand and stronger FC under RVC conditions than NRVC conditions, which indicated higher efficiency of cognitive resources allocation during stepping tasks. This study may provide a new insight for further understanding the mechanism on how RVCs alleviate freezing of gait.
- 12 February 2024
- Published by Frontiers Media SA in Frontiers in Human Neuroscience
- Vol. 18, 1337504
Open AccessEffects of rhythmic visual cues on cortical activation and functional connectivity features during stepping: an fNIRS study
Introduction: Rhythmic visual cues (RVCs) may influence gait initiation by modulating cognition resources. However, it is unknown how RVCs modulate cognitive resources allocation during gait movements. This study focused on investigating the effects of RVCs on cortical hemodynamic response features during stepping to evaluate the changes of cognitive resources.Methods: We recorded cerebral hemoglobin concentration changes of 14 channels in 17 healthy subjects using functional near-infrared spectroscopy (fNIRS) during stepping tasks under exposure to RVCs and non-rhythmic visual cues (NRVCs). We reported mean oxygenated hemoglobin (HbO) concentration changes, β-values, and functional connectivity (FC) between channels.Results: The results showed that, the RVC conditions revealed lower HbO responses compared to the NRVC conditions during the preparation and early stepping. Correspondingly, the β-values reflected that RVCs elicited lower hemodynamic responses than NRVCs, and there was a decreasing trend in stimulus-evoked cortical activation as the task progressed. However, the FC between channels were stronger under RVCs than under NRVCs during the stepping progress, and there were more significant differences in FC during the early stepping.Discussion: In conclusion, there were lower cognitive demand and stronger FC under RVC conditions than NRVC conditions, which indicated higher efficiency of cognitive resources allocation during stepping tasks. This study may provide a new insight for further understanding the mechanism on how RVCs alleviate freezing of gait.
- 19 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-14
Noncontact in Bed Measurements of Electrocardiogram Using a Capacitively Coupled Electrode Array Based on Flexible Circuit Board
Unconstrained vital sign monitoring technology has been a hot topic of research in recent years as people increasingly focus on their health status and sleep quality. Conventional contact electrocardiogram (ECG) measurement technology has difficulties in meeting the application needs of sleep scenarios due to short validity period and low comfort. To handle this problem, ECG measurement using non-contact capacitively coupled sensing technology, which do not require direct skin contact for ECG signal acquisition, could be an alternative. However, this method requires fixing the ECG measurement electrodes in two specific positions, which makes it difficult to meet the needs for body differences and multiple sleep postures. This study presents a non-contact sleep ECG measurement system based on a flexible electrode array, which can acquire ECG signals through pajamas and bed sheets using the principle of capacitive coupling. The experiment results showed that the average signal-to-noise ratio (SNR) of the data measured in the supine and lateral postures of subjects was above 30 dB, and the respiratory waves (RW) with the same frequency as contact ECG measurement system could be extracted. We also used this system to acquire ECG signals from multiple points on the dorsal of four subjects and analyzed their variation patterns, and the experimental results were in high agreement with the ECG potential employment recorded by 32-lead body surface maps. Meanwhile, the T-wave, R-wave, S-wave peaks and the ratio of T and R waves of the collected ECG signals were extracted as features. Based on this, the action classification model was trained using long short-term memory network (LSTM) to classify the postures of four subjects in supine, left lateral and right lateral positions, and the classification accuracies were 95.83%, 98.94%, 98.80% and 98.30%, respectively. Although our prototype system must be further improvement and development, these results provide a strong basis for future realization of electrode array-based ECG signal selection algorithms. The proposed system has great potential value in detecting abnormalities of ECG, heart rate (HR), respiration and other vital indicators during human sleep and realizing personalized medical treatment.
- 19 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-14
Noncontact in Bed Measurements of Electrocardiogram Using a Capacitively Coupled Electrode Array Based on Flexible Circuit Board
Unconstrained vital sign monitoring technology has been a hot topic of research in recent years as people increasingly focus on their health status and sleep quality. Conventional contact electrocardiogram (ECG) measurement technology has difficulties in meeting the application needs of sleep scenarios due to short validity period and low comfort. To handle this problem, ECG measurement using non-contact capacitively coupled sensing technology, which do not require direct skin contact for ECG signal acquisition, could be an alternative. However, this method requires fixing the ECG measurement electrodes in two specific positions, which makes it difficult to meet the needs for body differences and multiple sleep postures. This study presents a non-contact sleep ECG measurement system based on a flexible electrode array, which can acquire ECG signals through pajamas and bed sheets using the principle of capacitive coupling. The experiment results showed that the average signal-to-noise ratio (SNR) of the data measured in the supine and lateral postures of subjects was above 30 dB, and the respiratory waves (RW) with the same frequency as contact ECG measurement system could be extracted. We also used this system to acquire ECG signals from multiple points on the dorsal of four subjects and analyzed their variation patterns, and the experimental results were in high agreement with the ECG potential employment recorded by 32-lead body surface maps. Meanwhile, the T-wave, R-wave, S-wave peaks and the ratio of T and R waves of the collected ECG signals were extracted as features. Based on this, the action classification model was trained using long short-term memory network (LSTM) to classify the postures of four subjects in supine, left lateral and right lateral positions, and the classification accuracies were 95.83%, 98.94%, 98.80% and 98.30%, respectively. Although our prototype system must be further improvement and development, these results provide a strong basis for future realization of electrode array-based ECG signal selection algorithms. The proposed system has great potential value in detecting abnormalities of ECG, heart rate (HR), respiration and other vital indicators during human sleep and realizing personalized medical treatment.
- 23 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (19) , 23583-23596
Parallel High Capacitance Capacitors Connected With Flexible Electrodes for Enhancement of cECG Signal Quality
In the application for sleeping cardiac monitoring utilizing capacitive electrocardiogram (cECG), a raw cECG signal with high-fidelity is typically difficult to be obtained due to the low coupling capacitance made up of human skin, low dielectric fabrics and sensing electrodes. In order to overcome this challenge, this study proposed a parallel capacitor-flexible electrode for enhancing the performance of ECG monitoring system and investigated the influence of the parallel capacitors on ECG monitoring. Parallel capacitors at both ends of the coupling capacitance could increase the coupling capacitance and reduce the equivalent impedance, which could improve the signal-to-noise ratio (SNR) (from about 10dB to more than 30dB) of the acquired cECG signals. In this study, firstly, the optimal connection point and parallel capacitor were determined; secondly, the application of proposed system was demonstrated and well-characterized cECG signals (SNR 35.066dB) were obtained. The cECG signals acquired by the proposed and reference system were in good agreement. The calculated intervals of all subjects extracted from the cECG signals were within the standard interval ranges, which was consistent with the health condition of the subjects. The results also showed that the proposed system had an average HR error of 1.4% for 20 minutes compared to the reference system. In conclusion, this study innovatively proposed a method to enhance cECG signal quality, which has a promising potential for long-term sleeping ECG monitoring.
- 23 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (19) , 23583-23596
Parallel High Capacitance Capacitors Connected With Flexible Electrodes for Enhancement of cECG Signal Quality
In the application for sleeping cardiac monitoring utilizing capacitive electrocardiogram (cECG), a raw cECG signal with high-fidelity is typically difficult to be obtained due to the low coupling capacitance made up of human skin, low dielectric fabrics and sensing electrodes. In order to overcome this challenge, this study proposed a parallel capacitor-flexible electrode for enhancing the performance of ECG monitoring system and investigated the influence of the parallel capacitors on ECG monitoring. Parallel capacitors at both ends of the coupling capacitance could increase the coupling capacitance and reduce the equivalent impedance, which could improve the signal-to-noise ratio (SNR) (from about 10dB to more than 30dB) of the acquired cECG signals. In this study, firstly, the optimal connection point and parallel capacitor were determined; secondly, the application of proposed system was demonstrated and well-characterized cECG signals (SNR 35.066dB) were obtained. The cECG signals acquired by the proposed and reference system were in good agreement. The calculated intervals of all subjects extracted from the cECG signals were within the standard interval ranges, which was consistent with the health condition of the subjects. The results also showed that the proposed system had an average HR error of 1.4% for 20 minutes compared to the reference system. In conclusion, this study innovatively proposed a method to enhance cECG signal quality, which has a promising potential for long-term sleeping ECG monitoring.