Joaquin Cury
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Joaquin Cury has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Anne Vanhoestenberghe
School of Biomedical Engineering and Imaging Sciences, Kings College London, London, U.K.
4 shared publications - Antoine Nonclercq
Universite Libre de Bruxelles
4 shared publications - Hugo Smets
Bio-, Electro-and Mechanical-Systems (BEAMS), Université Libre de Bruxelles Faculté des sciences appliquées/Ecole polytechnique, Avenue Franklin Roosevelt 50 CP 165/56, Brussels, Brussels, 1050, BELGIUM
4 shared publications - Jean Delbeke
Private Address - Belgium, Seringenstraat 27, Kraainem, B-1950, BELGIUM
4 shared publications Pascal Doguet
Synergia Medical Mont‐Saint‐Guibert Belgium
4 shared publications- Riëm El Tahry
Clinical Neuroscience, Institute of Neuroscience Université Catholique de Louvain Brussels Belgium
3 shared publications
Latest Publications
- Open Access
- 18 November 2026
- Published by Frontiers Media SA in Frontiers in Audiology and Otology
- Vol. 4, 1910065
Polarized light microscopy to quantify changes in the tympanic membrane microstructure in chronic otitis media
Introduction: Chronic otitis media (COM) induces progressive structural remodeling of the tympanic membrane (TM), beginning with epithelial hyperplasia and advancing to disruption of the organized collagen architecture that underlies its mechanical behavior. Loss of collagen integrity within the TM has been associated with an increased risk of retraction and perforation, yet no clinically available method directly assesses layer-specific TM structure in vivo . Polarization-sensitive optical coherence tomography (PS-OCT) has recently been proposed as a promising approach for evaluating TM microstructure, but it has not yet been applied to pathologic TMs. Quantitative polarized light microscopy (qPLM) of diseased TM sections provides disease-relevant biological support for future evaluation of PS-OCT in pathologic TMs. We aimed to measure changes in optical retardance of collagen layers in both normal and pathologic TMs. Methods: Mice were intranasally inoculated with an upper respiratory pathogen to induce otitis media. Auditory brainstem responses were recorded before (baseline) and at 7 and 28 days post-inoculation (DPI) to confirm middle ear involvement. TMs from control and OM mice were harvested at 28 DPI, embedded in Araldite resin, and sectioned at 7 μm thickness. Optical retardance of TM collagen layers was quantified using polarized light microscopy. Polarized light microscopy for assessing the integrity of collagen structures was validated using harvested human TMs. Results: TM sections from mice with chronic otitis media exhibited notable alterations in optical retardance at 28 days post-inoculation (DPI). Regions of structural alteration demonstrated a significantly reduced mean retardance (4.62 ± 1.34 nm) compared with adjacent, unaltered regions within the same TM (9.78 ± 0.95 nm). Control TMs exhibited comparable retardance values (9.16 ± 0.87 nm). Retardance in altered TM regions was significantly lower than both unaltered regions of the same TM and control TMs ( p < 0.05 for both comparisons). This is consistent with collagen disorganization and tissue degradation associated with otitis media. Induced heat damage in a human TM shows similar changes in retardance to those seen in mouse models of OM. Conclusions: qPLM provides a robust method for evaluating TM structure following otitis media. Optical retardance was significantly reduced in regions classified as disrupted within COM TMs, consistent with progressive collagen degradation during disease. Once optimized, PS-OCT-equipped otoscopes may offer a valuable, clinically translatable approach for assessing TM layer integrity in vivo .
- 18 November 2026
- Published by Frontiers Media SA in Frontiers in Audiology and Otology
- Vol. 4, 1910065
Open AccessPolarized light microscopy to quantify changes in the tympanic membrane microstructure in chronic otitis media
Introduction: Chronic otitis media (COM) induces progressive structural remodeling of the tympanic membrane (TM), beginning with epithelial hyperplasia and advancing to disruption of the organized collagen architecture that underlies its mechanical behavior. Loss of collagen integrity within the TM has been associated with an increased risk of retraction and perforation, yet no clinically available method directly assesses layer-specific TM structure in vivo . Polarization-sensitive optical coherence tomography (PS-OCT) has recently been proposed as a promising approach for evaluating TM microstructure, but it has not yet been applied to pathologic TMs. Quantitative polarized light microscopy (qPLM) of diseased TM sections provides disease-relevant biological support for future evaluation of PS-OCT in pathologic TMs. We aimed to measure changes in optical retardance of collagen layers in both normal and pathologic TMs. Methods: Mice were intranasally inoculated with an upper respiratory pathogen to induce otitis media. Auditory brainstem responses were recorded before (baseline) and at 7 and 28 days post-inoculation (DPI) to confirm middle ear involvement. TMs from control and OM mice were harvested at 28 DPI, embedded in Araldite resin, and sectioned at 7 μm thickness. Optical retardance of TM collagen layers was quantified using polarized light microscopy. Polarized light microscopy for assessing the integrity of collagen structures was validated using harvested human TMs. Results: TM sections from mice with chronic otitis media exhibited notable alterations in optical retardance at 28 days post-inoculation (DPI). Regions of structural alteration demonstrated a significantly reduced mean retardance (4.62 ± 1.34 nm) compared with adjacent, unaltered regions within the same TM (9.78 ± 0.95 nm). Control TMs exhibited comparable retardance values (9.16 ± 0.87 nm). Retardance in altered TM regions was significantly lower than both unaltered regions of the same TM and control TMs ( p < 0.05 for both comparisons). This is consistent with collagen disorganization and tissue degradation associated with otitis media. Induced heat damage in a human TM shows similar changes in retardance to those seen in mouse models of OM. Conclusions: qPLM provides a robust method for evaluating TM structure following otitis media. Optical retardance was significantly reduced in regions classified as disrupted within COM TMs, consistent with progressive collagen degradation during disease. Once optimized, PS-OCT-equipped otoscopes may offer a valuable, clinically translatable approach for assessing TM layer integrity in vivo .
- Open Access
- 1 December 2024
- Published by KEAI Publishing in Bioactive Materials
- Vol. 42, 531-549
Enhancing biocompatibility of the brain-machine interface: A review
In vivo implantation of microelectrodes opens the door to studying neural circuits and restoring damaged neural pathways through direct electrical stimulation and recording. Although some neuroprostheses have achieved clinical success, electrode material properties, inflammatory response, and glial scar formation at the electrode-tissue interfaces affect performance and sustainability. Those challenges can be addressed by improving some of the materials' mechanical, physical, chemical, and electrical properties. This paper reviews materials and designs of current microelectrodes and discusses perspectives to advance neuroprosthetics performance.
- 1 December 2024
- Published by KEAI Publishing in Bioactive Materials
- Vol. 42, 531-549
Open AccessEnhancing biocompatibility of the brain-machine interface: A review
In vivo implantation of microelectrodes opens the door to studying neural circuits and restoring damaged neural pathways through direct electrical stimulation and recording. Although some neuroprostheses have achieved clinical success, electrode material properties, inflammatory response, and glial scar formation at the electrode-tissue interfaces affect performance and sustainability. Those challenges can be addressed by improving some of the materials' mechanical, physical, chemical, and electrical properties. This paper reviews materials and designs of current microelectrodes and discusses perspectives to advance neuroprosthetics performance.
- 8 July 2022
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 19 (4) , 046008
Chronic recording of the vagus nerve to analyze modulations by the light–dark cycle
Objective. The vagus nerve is considered to play a key role in the circadian rhythm. Chronic continuous analysis of the vagus nerve activity could contribute to a better understanding of the role of the vagus nerve in light–dark modulations. This paper presents a continuous analysis of spontaneous vagus nerve activity performed in four rats. Approach. We analyzed the vagus electroneurogram (VENG) and electroencephalogram (EEG) over a recording period of 28 d. Spike activity and heart rate estimation were derived from the VENG, and slow-wave activity was derived from the EEG. The presence of repetitive patterns was investigated with periodograms, cosinor fitting, autocorrelation, and statistical tests. The light–dark variations derived from the VENG spikes were compared with EEG slow waves, an established metric in circadian studies. Results. Our results demonstrate that light–dark variations can be detected in long-term vagus nerve activity monitoring. A recording period of about 7 d is required to characterize accurately the VENG light–dark variations. Significance. As a major outcome of this study, vagus nerve recordings hold the promise to help understand circadian regulation.
- 8 July 2022
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 19 (4) , 046008
Chronic recording of the vagus nerve to analyze modulations by the light–dark cycle
Objective. The vagus nerve is considered to play a key role in the circadian rhythm. Chronic continuous analysis of the vagus nerve activity could contribute to a better understanding of the role of the vagus nerve in light–dark modulations. This paper presents a continuous analysis of spontaneous vagus nerve activity performed in four rats. Approach. We analyzed the vagus electroneurogram (VENG) and electroencephalogram (EEG) over a recording period of 28 d. Spike activity and heart rate estimation were derived from the VENG, and slow-wave activity was derived from the EEG. The presence of repetitive patterns was investigated with periodograms, cosinor fitting, autocorrelation, and statistical tests. The light–dark variations derived from the VENG spikes were compared with EEG slow waves, an established metric in circadian studies. Results. Our results demonstrate that light–dark variations can be detected in long-term vagus nerve activity monitoring. A recording period of about 7 d is required to characterize accurately the VENG light–dark variations. Significance. As a major outcome of this study, vagus nerve recordings hold the promise to help understand circadian regulation.
- 8 July 2022
- Published by Wiley in Journal of Biophotonics
- Vol. 15 (10) , e202200028
Optical birefringence changes in myelinated and unmyelinated nerves: A comparative study
The measurement of birefringence variations related to nerve activity is a promising label‐free technique for sensing compound neural action potentials (CNAPs). While widely applied in crustaceans, little is known about its efficiency on mammal peripheral nerves. In this work, birefringence recordings to detect CNAPs, and Stokes parameters measurements were performed in rat and lobster nerves. While single‐trial detection of nerve activity in crustaceans was achieved successfully, no optical signal was detected in rats, even after extensive signal filtering and averaging. The Stokes parameters showed that a high degree of polarization of light is maintained in lobster sample, whereas an almost complete light depolarization occurs in rat nerve. Our results indicate that depolarization itself is not sufficient to explain the absence of birefringence signals in rats. We hypothesize that this absence comes from the myelin sheets, which constraint the birefringence changes to only take place at the nodes of Ranvier.
- 8 July 2022
- Published by Wiley in Journal of Biophotonics
- Vol. 15 (10) , e202200028
Optical birefringence changes in myelinated and unmyelinated nerves: A comparative study
The measurement of birefringence variations related to nerve activity is a promising label‐free technique for sensing compound neural action potentials (CNAPs). While widely applied in crustaceans, little is known about its efficiency on mammal peripheral nerves. In this work, birefringence recordings to detect CNAPs, and Stokes parameters measurements were performed in rat and lobster nerves. While single‐trial detection of nerve activity in crustaceans was achieved successfully, no optical signal was detected in rats, even after extensive signal filtering and averaging. The Stokes parameters showed that a high degree of polarization of light is maintained in lobster sample, whereas an almost complete light depolarization occurs in rat nerve. Our results indicate that depolarization itself is not sufficient to explain the absence of birefringence signals in rats. We hypothesize that this absence comes from the myelin sheets, which constraint the birefringence changes to only take place at the nodes of Ranvier.
- 9 April 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (5) , 056018
Infrared neurostimulation in ex-vivo rat sciatic nerve using 1470 nm wavelength
Objective. To design and implement a setup for ex-vivo optical stimulation for exploring the effect of several key parameters (optical power and pulse duration), activation features (threshold, spatial selectivity) and recovery characteristics (repeated stimuli) in peripheral nerves. Approach. A nerve chamber allowing ex-vivo electrical and optical stimulation was designed and built. A 1470 nm light source was chosen to stimulate the nerve. A photodiode module was implemented for synchronization of the electrical and optical channels. Main results . Compound neural action potentials (CNAPs) were successfully generated with infrared light pulses of 200–2000 µ s duration and power in the range of 3–10 W. These parameters determine a radiant exposure for stimulation in the range 1.59–4.78 J cm −2 . Recruitment curves were obtained by increasing durations at a constant power level. Neural activation threshold is reached at a mean radiant exposure of 3.16 ± 0.68 J cm −2 and mean pulse energy of 3.79 ± 0.72 mJ. Repetition rates of 2–10 Hz have been explored. In eight out of ten sciatic nerves (SNs), repeated light stimuli induced a sensitization effect in that the CNAP amplitude progressively grows, representing an increasing number of recruited fibres. In two out of ten SNs, CNAPs were composed of a succession of peaks corresponding to different conduction velocities. Significance. The reported sensitization effect could shed light on the mechanism underlying infrared neurostimulation. Our results suggest that, in sharp contrast with electrical stimuli, optical pulses could recruit slow fibres early on. This more physiological order of recruitment opens the perspective for specific neuromodulation of fibre population who remained poorly accessible until now. Short high-power light pulses at wavelengths below 1.5 µ m offer interesting perspectives for neurostimulation.
- 9 April 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (5) , 056018
Infrared neurostimulation in ex-vivo rat sciatic nerve using 1470 nm wavelength
Objective. To design and implement a setup for ex-vivo optical stimulation for exploring the effect of several key parameters (optical power and pulse duration), activation features (threshold, spatial selectivity) and recovery characteristics (repeated stimuli) in peripheral nerves. Approach. A nerve chamber allowing ex-vivo electrical and optical stimulation was designed and built. A 1470 nm light source was chosen to stimulate the nerve. A photodiode module was implemented for synchronization of the electrical and optical channels. Main results . Compound neural action potentials (CNAPs) were successfully generated with infrared light pulses of 200–2000 µ s duration and power in the range of 3–10 W. These parameters determine a radiant exposure for stimulation in the range 1.59–4.78 J cm −2 . Recruitment curves were obtained by increasing durations at a constant power level. Neural activation threshold is reached at a mean radiant exposure of 3.16 ± 0.68 J cm −2 and mean pulse energy of 3.79 ± 0.72 mJ. Repetition rates of 2–10 Hz have been explored. In eight out of ten sciatic nerves (SNs), repeated light stimuli induced a sensitization effect in that the CNAP amplitude progressively grows, representing an increasing number of recruited fibres. In two out of ten SNs, CNAPs were composed of a succession of peaks corresponding to different conduction velocities. Significance. The reported sensitization effect could shed light on the mechanism underlying infrared neurostimulation. Our results suggest that, in sharp contrast with electrical stimuli, optical pulses could recruit slow fibres early on. This more physiological order of recruitment opens the perspective for specific neuromodulation of fibre population who remained poorly accessible until now. Short high-power light pulses at wavelengths below 1.5 µ m offer interesting perspectives for neurostimulation.
- 15 February 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (5) , 056008
Analysing vagus nerve spontaneous activity using finite element modelling
Objective. Finite element modelling has been widely used to understand the effect of stimulation on the nerve fibres. Yet the literature on analysis of spontaneous nerve activity is much scarcer. In this study, we introduce a method based on a finite element model, to analyse spontaneous nerve activity with a typical bipolar electrode recording setup, enabling the identification of spontaneously active fibres. We applied our method to the vagus nerve, which plays a key role in refractory epilepsy. Approach. We developed a 3D model including dynamic action potential propagation, based on the vagus nerve geometry. The impact of key recording parameters – inter-electrode distance and temperature – and uncontrolled parameters – fibre size and position in the nerve – on the ability to discriminate active fibres were quantified. A specific algorithm was implemented to detect and classify action potentials from recordings and tested on six rats in vivo vagus nerve recordings. Main results. Fibre diameters can be discriminated if they are below 3 µm and 7 µm, respectively for inter-electrode distances of 2 mm and 4 mm. The impact of the position of the fibre inside the nerve on fibre diameter discrimination, is limited. The range of active fibres identified by modelling in the vagus nerve of rats is in agreement with ranges found at histology. Significance. The nerve fibre diameter, directly proportional to the action potential propagation velocity, is related to a specific physiological function. Estimating the source fibre diameter is thus essential to interpret neural recordings. Among many possible applications, the present method was developed in the context of a project to improve vagus nerve stimulation therapy for epilepsy.
- 15 February 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (5) , 056008
Analysing vagus nerve spontaneous activity using finite element modelling
Objective. Finite element modelling has been widely used to understand the effect of stimulation on the nerve fibres. Yet the literature on analysis of spontaneous nerve activity is much scarcer. In this study, we introduce a method based on a finite element model, to analyse spontaneous nerve activity with a typical bipolar electrode recording setup, enabling the identification of spontaneously active fibres. We applied our method to the vagus nerve, which plays a key role in refractory epilepsy. Approach. We developed a 3D model including dynamic action potential propagation, based on the vagus nerve geometry. The impact of key recording parameters – inter-electrode distance and temperature – and uncontrolled parameters – fibre size and position in the nerve – on the ability to discriminate active fibres were quantified. A specific algorithm was implemented to detect and classify action potentials from recordings and tested on six rats in vivo vagus nerve recordings. Main results. Fibre diameters can be discriminated if they are below 3 µm and 7 µm, respectively for inter-electrode distances of 2 mm and 4 mm. The impact of the position of the fibre inside the nerve on fibre diameter discrimination, is limited. The range of active fibres identified by modelling in the vagus nerve of rats is in agreement with ranges found at histology. Significance. The nerve fibre diameter, directly proportional to the action potential propagation velocity, is related to a specific physiological function. Estimating the source fibre diameter is thus essential to interpret neural recordings. Among many possible applications, the present method was developed in the context of a project to improve vagus nerve stimulation therapy for epilepsy.