Rachel M. E. Cahalane
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Rachel M. E. Cahalane has a total of 104 co-authors. Here are the top co-authors by number of shared publications:
- Aisling M. Ross
The Walter & Eliza Hall Institute of Medical Research
3 shared publications - John Joseph Eugene Mulvihill
University of Limerick
3 shared publications - Michael T. Walsh
BioMaterials Cluster, Bernal Institute, University of Limerick, Limerick, Ireland
3 shared publications Busra Cangut
Mount Sinai
2 shared publications- Dylan Armfield
School of Mechanical and Materials Engineering, University College Dublin, Dublin, Ireland; SFI I-Form Centre, University College Dublin, Dublin, Ireland
2 shared publications Eamon G. Kavanagh
Department of Vascular Surgery, University Hospital Limerick, Ireland
2 shared publications
Latest Publications
- Open Access
- 1 October 2025
- Published by SAGE Publications in Journal of the Heart Valve Society
- Vol. 2 (3-4) , 411-414
The Young Professionals Network: Building Momentum and Shaping the Future of the Heart Valve Society
The Heart Valve Society Young Professional Network Board Initiative was established to foster the professional development, scientific engagement, and leadership potential of early career clinicians and researchers in the field of heart valve disease. Building on our previously published mission and vision, the initiative serves as a dynamic and inclusive platform for mentorship, interdisciplinary collaboration, and scientific engagement. It envisions a future where emerging leaders drive innovation and excellence in patient care, research, and education, strengthening the global heart valve community.
- 1 October 2025
- Published by SAGE Publications in Journal of the Heart Valve Society
- Vol. 2 (3-4) , 411-414
Open AccessThe Young Professionals Network: Building Momentum and Shaping the Future of the Heart Valve Society
The Heart Valve Society Young Professional Network Board Initiative was established to foster the professional development, scientific engagement, and leadership potential of early career clinicians and researchers in the field of heart valve disease. Building on our previously published mission and vision, the initiative serves as a dynamic and inclusive platform for mentorship, interdisciplinary collaboration, and scientific engagement. It envisions a future where emerging leaders drive innovation and excellence in patient care, research, and education, strengthening the global heart valve community.
- Open Access
In Silico Modeling of Transcatheter Heart Valve Oversizing and Ellipticity, Part I: Establishing Credibility of an Advanced Model
Background and Objectives: Transcatheter aortic valve implantation (TAVI) is the most common modality of treatment for aortic stenosis. However, transcatheter heart valves (THVs) can be prone to early failure and an increase in thrombogenic events, yet the risk factors associated with these failure modes remain poorly understood. Computational modeling may be used to predict biomechanical indices associated with degeneration and thrombogenicity, however existing models do not fully account for complex stent and leaflet material behavior, and establishing model credibility according to ASME VV-40 is required. Methods: In this study, we developed an advanced structural and hemodynamic in silico framework to predict the in vitro performance of a supra-annular, self-expanding THV across a range of clinically-relevant expansion and ellipticity indices. The THV was modelled by incorporating a novel 3-fibre material model for pericardium tissue leaflets and a super-elastic nitinol stent. Results: Calculation verification was conducted and, on this basis, we provide recommendations on mesh density, element integration and target time increment. Following verification, we validated our models with radial force, structural camera and hemodynamic particle image velocimetry testing across multiple THV deployment configurations. In the ‘min-oversizing, circular’ case, we predicted a similar geometric orifice area (4.35 vs 4.02cm 2 ), pinwheeling index (2.6% vs 2.7%), stent deflection (1.95 vs 1.76mm) and flow velocity (1.33 vs 1.27m/s) to in vitro data. Conclusion: Thus, we validated a novel structural and hemodynamic in silico framework for studying THVs, which will be applied to understand deployment factors contributing to structural degeneration and thrombogenicity. This framework also holds potential for guiding next-generation THV design and predictive procedural modeling.
Open AccessIn Silico Modeling of Transcatheter Heart Valve Oversizing and Ellipticity, Part I: Establishing Credibility of an Advanced Model
Background and Objectives: Transcatheter aortic valve implantation (TAVI) is the most common modality of treatment for aortic stenosis. However, transcatheter heart valves (THVs) can be prone to early failure and an increase in thrombogenic events, yet the risk factors associated with these failure modes remain poorly understood. Computational modeling may be used to predict biomechanical indices associated with degeneration and thrombogenicity, however existing models do not fully account for complex stent and leaflet material behavior, and establishing model credibility according to ASME VV-40 is required. Methods: In this study, we developed an advanced structural and hemodynamic in silico framework to predict the in vitro performance of a supra-annular, self-expanding THV across a range of clinically-relevant expansion and ellipticity indices. The THV was modelled by incorporating a novel 3-fibre material model for pericardium tissue leaflets and a super-elastic nitinol stent. Results: Calculation verification was conducted and, on this basis, we provide recommendations on mesh density, element integration and target time increment. Following verification, we validated our models with radial force, structural camera and hemodynamic particle image velocimetry testing across multiple THV deployment configurations. In the ‘min-oversizing, circular’ case, we predicted a similar geometric orifice area (4.35 vs 4.02cm 2 ), pinwheeling index (2.6% vs 2.7%), stent deflection (1.95 vs 1.76mm) and flow velocity (1.33 vs 1.27m/s) to in vitro data. Conclusion: Thus, we validated a novel structural and hemodynamic in silico framework for studying THVs, which will be applied to understand deployment factors contributing to structural degeneration and thrombogenicity. This framework also holds potential for guiding next-generation THV design and predictive procedural modeling.
- Open Access
In Silico Modeling of Transcatheter Heart Valve Oversizing and Ellipticity, Part II: Effects on Leaflet Mechanics, Hemodynamics, and Stent Deflection Contributing to Thrombogenic Risk and Structural Degeneration
Background and Objectives: Transcatheter aortic valve implantation (TAVI) is the leading treatment for aortic stenosis. Self-expanding transcatheter heart valves (THVs) are oversized to prevent paravalvular leakage and then deployed over the diseased native valve. However, this can result in incomplete expansion and elliptical deployment, which may influence thrombogenic risk and structural degeneration, although this is not fully understood. Methods: In this study, we utilized a validated in silico framework to assess the impact of THV oversizing and ellipticity on leaflet mechanics, hemodynamic shear stress and stent deformation, which are indicators of structural degeneration and thrombogenicity. We simulated self-expansion of a deformable THV stent within an idealized aortic annulus, applied pulsatile loading conditions representative of the cardiac cycle and then evaluated post-deployment frame deformation, leaflet mechanics, hemodynamics and stent fatigue. Results: We predicted ‘stent-frame decoupling’ of the supra-annular THV, with increased expansion and circularity at the functional valve level compared to the inflow. Maximal oversizing of the THV reduced valve expansion at the supra-annular valve level (< 90% expansion), which increased leaflet coaptation and pinwheeling, but reduced peak leaflet stresses and stent deflection. Maximal oversizing also altered hemodynamics, causing early mainstream flow separation, which increased leaflet oscillatory shear and viscous shear stress downstream of the THV, potentially increasing thrombogenic risk and promoting tissue degeneration. THV ellipticity induced heterogenous stent deflections, leading to variable leaflet stress distributions and coaptation mismatch. Conclusion: We propose that flexible THV stents may mitigate adverse effects of elliptical deployment and emphasize the importance of assessing THV expansion through fluoroscopy and considering post-TAVI balloon-dilatation to increase expansion and improve long-term functional valve performance.
Open AccessIn Silico Modeling of Transcatheter Heart Valve Oversizing and Ellipticity, Part II: Effects on Leaflet Mechanics, Hemodynamics, and Stent Deflection Contributing to Thrombogenic Risk and Structural Degeneration
Background and Objectives: Transcatheter aortic valve implantation (TAVI) is the leading treatment for aortic stenosis. Self-expanding transcatheter heart valves (THVs) are oversized to prevent paravalvular leakage and then deployed over the diseased native valve. However, this can result in incomplete expansion and elliptical deployment, which may influence thrombogenic risk and structural degeneration, although this is not fully understood. Methods: In this study, we utilized a validated in silico framework to assess the impact of THV oversizing and ellipticity on leaflet mechanics, hemodynamic shear stress and stent deformation, which are indicators of structural degeneration and thrombogenicity. We simulated self-expansion of a deformable THV stent within an idealized aortic annulus, applied pulsatile loading conditions representative of the cardiac cycle and then evaluated post-deployment frame deformation, leaflet mechanics, hemodynamics and stent fatigue. Results: We predicted ‘stent-frame decoupling’ of the supra-annular THV, with increased expansion and circularity at the functional valve level compared to the inflow. Maximal oversizing of the THV reduced valve expansion at the supra-annular valve level (< 90% expansion), which increased leaflet coaptation and pinwheeling, but reduced peak leaflet stresses and stent deflection. Maximal oversizing also altered hemodynamics, causing early mainstream flow separation, which increased leaflet oscillatory shear and viscous shear stress downstream of the THV, potentially increasing thrombogenic risk and promoting tissue degeneration. THV ellipticity induced heterogenous stent deflections, leading to variable leaflet stress distributions and coaptation mismatch. Conclusion: We propose that flexible THV stents may mitigate adverse effects of elliptical deployment and emphasize the importance of assessing THV expansion through fluoroscopy and considering post-TAVI balloon-dilatation to increase expansion and improve long-term functional valve performance.
- Open Access
- 1 July 2025
- Published by Wolters Kluwer Health in Arteriosclerosis, Thrombosis, and Vascular Biology
- Vol. 45 (7) , 1277-1305
Multiomic Landscape of Extracellular Vesicles in Human Carotid Atherosclerotic Plaque Reveals Endothelial Communication Networks
BACKGROUND: Carotid atherosclerosis is orchestrated by cell-cell communication that drives progression along a clinical continuum (asymptomatic to symptomatic). Extracellular vesicles (EVs) are cell-derived nanoparticles representing a new paradigm in cellular communication. Little is known about their biological cargo, cellular origin/destination, and functional roles in human atherosclerotic plaque. METHODS: EVs were enriched via size exclusion chromatography from human carotid endarterectomy samples dissected into paired plaque and marginal zones (symptomatic n=16, asymptomatic n=13). EV-cargos were assessed via whole transcriptome microRNA-sequencing and mass spectrometry–based proteomics. EV multiomics was integrated with bulk and single-cell RNA-sequencing datasets to predict EV cellular origin and ligand-receptor interactions, and multimodal biological network integration of EV-cargo was completed. EV functional impact was assessed with endothelial angiogenesis assays. RESULTS: Carotid plaques contained more EVs than adjacent marginal zones, with differential enrichment for EV-microRNAs and EV-proteins in key atherogenic pathways. EV cellular origin analysis suggested that tissue EV signatures originated from endothelial cells, smooth muscle cells, and immune cells. Integrated tissue vesiculomics and single-cell RNA-sequencing indicated complex EV–vascular cell communication that changed with disease progression and plaque vulnerability (ie, symptomatic disease). Plaques from symptomatic patients, but not asymptomatic patients, were characterized by increased involvement of endothelial pathways and more complex ligand-receptor interactions, relative to their marginal zones. Plaque EVs were predicted to mediate communication with endothelial cells. Pathway enrichment analysis delineated an endothelial signature with roles in angiogenesis and neovascularization, well-known indices of plaque instability. This was validated functionally, wherein human carotid symptomatic plaque EVs induced sprouting angiogenesis in comparison to their matched marginal zones. CONCLUSIONS: Our findings indicate that EVs may drive dynamic changes in plaques through EV–vascular cell communication and effector functions that typify vulnerability to rupture, precipitating symptomatic disease. The discovery of endothelial-directed angiogenic processes mediated by EVs creates new therapeutic avenues for atherosclerosis.
- 1 July 2025
- Published by Wolters Kluwer Health in Arteriosclerosis, Thrombosis, and Vascular Biology
- Vol. 45 (7) , 1277-1305
Open AccessMultiomic Landscape of Extracellular Vesicles in Human Carotid Atherosclerotic Plaque Reveals Endothelial Communication Networks
BACKGROUND: Carotid atherosclerosis is orchestrated by cell-cell communication that drives progression along a clinical continuum (asymptomatic to symptomatic). Extracellular vesicles (EVs) are cell-derived nanoparticles representing a new paradigm in cellular communication. Little is known about their biological cargo, cellular origin/destination, and functional roles in human atherosclerotic plaque. METHODS: EVs were enriched via size exclusion chromatography from human carotid endarterectomy samples dissected into paired plaque and marginal zones (symptomatic n=16, asymptomatic n=13). EV-cargos were assessed via whole transcriptome microRNA-sequencing and mass spectrometry–based proteomics. EV multiomics was integrated with bulk and single-cell RNA-sequencing datasets to predict EV cellular origin and ligand-receptor interactions, and multimodal biological network integration of EV-cargo was completed. EV functional impact was assessed with endothelial angiogenesis assays. RESULTS: Carotid plaques contained more EVs than adjacent marginal zones, with differential enrichment for EV-microRNAs and EV-proteins in key atherogenic pathways. EV cellular origin analysis suggested that tissue EV signatures originated from endothelial cells, smooth muscle cells, and immune cells. Integrated tissue vesiculomics and single-cell RNA-sequencing indicated complex EV–vascular cell communication that changed with disease progression and plaque vulnerability (ie, symptomatic disease). Plaques from symptomatic patients, but not asymptomatic patients, were characterized by increased involvement of endothelial pathways and more complex ligand-receptor interactions, relative to their marginal zones. Plaque EVs were predicted to mediate communication with endothelial cells. Pathway enrichment analysis delineated an endothelial signature with roles in angiogenesis and neovascularization, well-known indices of plaque instability. This was validated functionally, wherein human carotid symptomatic plaque EVs induced sprouting angiogenesis in comparison to their matched marginal zones. CONCLUSIONS: Our findings indicate that EVs may drive dynamic changes in plaques through EV–vascular cell communication and effector functions that typify vulnerability to rupture, precipitating symptomatic disease. The discovery of endothelial-directed angiogenic processes mediated by EVs creates new therapeutic avenues for atherosclerosis.
- Open Access
Cross-species proteomics quantification pipeline distinguishes donor versus host extracellular matrix in explanted biomaterials
Xenogenic biomaterial durability, including bioprosthetic heart valves (BPVs), is compromised by pathological extracellular matrix (ECM) remodeling, resulting in progressive structural degeneration. Mass spectrometry-based proteomics can help reveal BPV degeneration mechanisms; however, peptide sequence similarity between donor and host species complicates protein-level analysis. We present a cross-species proteomic analytical strategy for xenogenic biomaterials and cross-species proteomic datasets. In silico tryptic digestion of human and bovine protein databases identified over 400 overlapping proteins with a high protein percent identity. Explanted human BPV tissue was divided into macroscopically distinct regions of degeneration and analyzed by mass spectrometry. A peptide-level strategy quantified protein abundances in a species-delineated analysis. We highlighted degeneration region-specific depositions of key human ECM proteins and bovine ECM proteins whose abundance is time dependent. We demonstrated that single-species analysis of a cross-species proteome results in inaccurate quantification. This study highlights the importance of distinguishing between donor and host species proteomes for accurate protein quantification. While focused on clinically explanted biomaterials, our approach is broadly applicable to all forms of xenotransplantation and the use of xenogenic matrices.
Open AccessCross-species proteomics quantification pipeline distinguishes donor versus host extracellular matrix in explanted biomaterials
Xenogenic biomaterial durability, including bioprosthetic heart valves (BPVs), is compromised by pathological extracellular matrix (ECM) remodeling, resulting in progressive structural degeneration. Mass spectrometry-based proteomics can help reveal BPV degeneration mechanisms; however, peptide sequence similarity between donor and host species complicates protein-level analysis. We present a cross-species proteomic analytical strategy for xenogenic biomaterials and cross-species proteomic datasets. In silico tryptic digestion of human and bovine protein databases identified over 400 overlapping proteins with a high protein percent identity. Explanted human BPV tissue was divided into macroscopically distinct regions of degeneration and analyzed by mass spectrometry. A peptide-level strategy quantified protein abundances in a species-delineated analysis. We highlighted degeneration region-specific depositions of key human ECM proteins and bovine ECM proteins whose abundance is time dependent. We demonstrated that single-species analysis of a cross-species proteome results in inaccurate quantification. This study highlights the importance of distinguishing between donor and host species proteomes for accurate protein quantification. While focused on clinically explanted biomaterials, our approach is broadly applicable to all forms of xenotransplantation and the use of xenogenic matrices.
- Open Access
- 1 October 2024
- Published by SAGE Publications in Journal of the Heart Valve Society
- Vol. 1 (1)
The Young Professionals Network: A New Initiative for The Heart Valve Society
- 1 October 2024
- Published by SAGE Publications in Journal of the Heart Valve Society
- Vol. 1 (1)
Open AccessThe Young Professionals Network: A New Initiative for The Heart Valve Society
- Open Access
- 13 November 2023
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (11) , e0293456
The association between human blood clot analogue computed tomography imaging, composition, contraction, and mechanical characteristics
Background: Clot composition, contraction, and mechanical properties are likely determinants of endovascular thrombectomy success. A pre-interventional estimation of these properties is hypothesized to aid in selecting the most suitable treatment for different types of thrombi. Here we determined the association between the aforementioned properties and computed tomography (CT) characteristics using human blood clot analogues. Methods: Clot analogues were prepared from the blood of 4 healthy human donors with 5 red blood cell (RBC) volume suspensions: 0%, 20%, 40%, 60% and 80% RBCs. Contraction was measured as the weight of the contracted clots as a percentage of the original suspension. The clots were imaged using CT with and without contrast to quantify clot density and density increase. Unconfined compression was performed to determine the high strain compressive stiffness. The RBC content was analysed using H&E staining. Results: The 5 RBC suspensions formed only two groups of clots, fibrin-rich (0% RBCs) and RBC-rich (>90% RBCs), as determined by histology. The density of the fibrin-rich clots was significantly lower (31-38HU) compared to the RBC-rich clots (72-89HU), and the density increase of the fibrin-rich clots was significantly higher (82-127HU) compared to the RBC-rich clots (3-17HU). The compressive stiffness of the fibrin-rich clots was higher (178–1624 kPa) than the stiffness of the RBC-rich clots (6–526 kPa). Additionally, the degree of clot contraction was higher for the fibrin-rich clots (89–96%) compared to the RBC-rich clots (11–77%). Conclusions: CT imaging clearly reflects clot RBC content and seems to be related to the clot contraction and stiffness. CT imaging might be a useful tool in predicting the thrombus characteristics. However, future studies should confirm these findings by analysing clots with intermediate RBC and platelet content.
- 13 November 2023
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (11) , e0293456
Open AccessThe association between human blood clot analogue computed tomography imaging, composition, contraction, and mechanical characteristics
Background: Clot composition, contraction, and mechanical properties are likely determinants of endovascular thrombectomy success. A pre-interventional estimation of these properties is hypothesized to aid in selecting the most suitable treatment for different types of thrombi. Here we determined the association between the aforementioned properties and computed tomography (CT) characteristics using human blood clot analogues. Methods: Clot analogues were prepared from the blood of 4 healthy human donors with 5 red blood cell (RBC) volume suspensions: 0%, 20%, 40%, 60% and 80% RBCs. Contraction was measured as the weight of the contracted clots as a percentage of the original suspension. The clots were imaged using CT with and without contrast to quantify clot density and density increase. Unconfined compression was performed to determine the high strain compressive stiffness. The RBC content was analysed using H&E staining. Results: The 5 RBC suspensions formed only two groups of clots, fibrin-rich (0% RBCs) and RBC-rich (>90% RBCs), as determined by histology. The density of the fibrin-rich clots was significantly lower (31-38HU) compared to the RBC-rich clots (72-89HU), and the density increase of the fibrin-rich clots was significantly higher (82-127HU) compared to the RBC-rich clots (3-17HU). The compressive stiffness of the fibrin-rich clots was higher (178–1624 kPa) than the stiffness of the RBC-rich clots (6–526 kPa). Additionally, the degree of clot contraction was higher for the fibrin-rich clots (89–96%) compared to the RBC-rich clots (11–77%). Conclusions: CT imaging clearly reflects clot RBC content and seems to be related to the clot contraction and stiffness. CT imaging might be a useful tool in predicting the thrombus characteristics. However, future studies should confirm these findings by analysing clots with intermediate RBC and platelet content.
- Open Access
- 4 July 2023
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 12 (13) , e027866
Cross‐Sectional Validation of a Novel Computed Tomography‐Based Carotid Mean Calcium Density Measurement
Background: The purpose of this study was to validate a technique for measuring mean calcium density and to determine associations of cardiovascular risk factors with carotid calcium density. Methods and Results: We performed a cross‐sectional study in a random sample of 100 stroke‐free participants from the population‐based Rotterdam Study. The mean calcium density of the combined left and right carotid bifurcations was quantified with a threshold of 130 Hounsfield Units (HU) using a novel density technique. To validate the methodology, carotid calcium volumes acquired using the technique in the current study were compared with measurements computed using dedicated clinical software (semiautomatic technique based on a threshold of ≥130 HU). Next, we investigated the associations of participant demographics, total calcium volume, and known cardiovascular risk factors (hypertension, diabetes, hypercholesterolemia, obesity, and smoking status) with the newly derived mean carotid calcium density measurement using linear regression analyses. Calcium volumes obtained with the 2 methods showed a high agreement (intraclass correlation coefficient=0.99, P P P =0.017). No other significant associations were found between participant demographics or cardiovascular risk factors and mean carotid calcium density. Conclusions: We demonstrated the feasibility of a carotid calcium density measurement technique. The data warrant a subsequent longitudinal study to determine the association between carotid calcium density and the risk of cerebrovascular events.
- 4 July 2023
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 12 (13) , e027866
Open AccessCross‐Sectional Validation of a Novel Computed Tomography‐Based Carotid Mean Calcium Density Measurement
Background: The purpose of this study was to validate a technique for measuring mean calcium density and to determine associations of cardiovascular risk factors with carotid calcium density. Methods and Results: We performed a cross‐sectional study in a random sample of 100 stroke‐free participants from the population‐based Rotterdam Study. The mean calcium density of the combined left and right carotid bifurcations was quantified with a threshold of 130 Hounsfield Units (HU) using a novel density technique. To validate the methodology, carotid calcium volumes acquired using the technique in the current study were compared with measurements computed using dedicated clinical software (semiautomatic technique based on a threshold of ≥130 HU). Next, we investigated the associations of participant demographics, total calcium volume, and known cardiovascular risk factors (hypertension, diabetes, hypercholesterolemia, obesity, and smoking status) with the newly derived mean carotid calcium density measurement using linear regression analyses. Calcium volumes obtained with the 2 methods showed a high agreement (intraclass correlation coefficient=0.99, P P P =0.017). No other significant associations were found between participant demographics or cardiovascular risk factors and mean carotid calcium density. Conclusions: We demonstrated the feasibility of a carotid calcium density measurement technique. The data warrant a subsequent longitudinal study to determine the association between carotid calcium density and the risk of cerebrovascular events.
- Open Access
- 6 January 2023
- Published by MDPI AG in Pharmaceutics
- Vol. 15 (1) , 200
Identification of Nanoparticle Properties for Optimal Drug Delivery across a Physiological Cell Barrier
Nanoparticles (NPs) represent an attractive strategy to overcome difficulties associated with the delivery of therapeutics. Knowing the optimal properties of NPs to address these issues could allow for improved in vivo responses. This work investigated NPs prepared from 5 materials of 3 sizes and 3 concentrations applied to a cell barrier model. The NPs permeability across a cell barrier and their effects on cell barrier integrity and cell viability were evaluated. The properties of these NPs, as determined in water (traditional) vs. media (realistic), were compared to cell responses. It was found that for all cellular activities, NP properties determined in media was the best predictor of the cell response. Notably, ZnO NPs caused significant alterations to cell viability across all 3 cell lines tested. Importantly, we report that the zeta potential of NPs correlates significantly with NP permeability and NP-induced changes in cell viability. NPs with physiological-based zeta potential of −12 mV result in good cell barrier penetration without considerable changes in cell viability.
- 6 January 2023
- Published by MDPI AG in Pharmaceutics
- Vol. 15 (1) , 200
Open AccessIdentification of Nanoparticle Properties for Optimal Drug Delivery across a Physiological Cell Barrier
Nanoparticles (NPs) represent an attractive strategy to overcome difficulties associated with the delivery of therapeutics. Knowing the optimal properties of NPs to address these issues could allow for improved in vivo responses. This work investigated NPs prepared from 5 materials of 3 sizes and 3 concentrations applied to a cell barrier model. The NPs permeability across a cell barrier and their effects on cell barrier integrity and cell viability were evaluated. The properties of these NPs, as determined in water (traditional) vs. media (realistic), were compared to cell responses. It was found that for all cellular activities, NP properties determined in media was the best predictor of the cell response. Notably, ZnO NPs caused significant alterations to cell viability across all 3 cell lines tested. Importantly, we report that the zeta potential of NPs correlates significantly with NP permeability and NP-induced changes in cell viability. NPs with physiological-based zeta potential of −12 mV result in good cell barrier penetration without considerable changes in cell viability.
- Open Access
- 1 September 2021
- Published by Elsevier in Biochemistry and Biophysics Reports
- Vol. 27, 101096
The effect of serum starvation on tight junctional proteins and barrier formation in Caco-2 cells
- 1 September 2021
- Published by Elsevier in Biochemistry and Biophysics Reports
- Vol. 27, 101096
Open AccessThe effect of serum starvation on tight junctional proteins and barrier formation in Caco-2 cells