Muhammad Tauseef Nasir
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Muhammad Tauseef Nasir has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Kyung Chun Kim
Eco-friendly Smart Ship Parts Technology Innovation Center, Pusan National University, Busan 46241, Republic of Korea
3 shared publications - Michael Chukwuemeka Ekwonu
School of Mechanical Engineering, Pusan National University, Busan 46241, Korea
3 shared publications - Javad Abolfazli Esfahani
Mechanical Engineering Department, Faculty of Engineering, Ferdowsi University of Mashhad, Mashhad, Iran
2 shared publications - Binqi Chen
School of Aeronautics and Astronautics, University of Electronic Science and Technology of China, Chengdu, China
1 shared publication - Mirae Kim
School of Mechanical Engineering, Eco-friendly Smart Ship Parts Technology Innovation Center, Pusan National University, Busan, Republic of Korea
1 shared publication - Yoonseong Park
School of Mechanical Engineering, Pusan National University, Busan 46241, Korea
1 shared publication
Latest Publications
- Open Access
Dynamic Simulation of Partial Load Operation of an Organic Rankine Cycle with Two Parallel Expanders
The parallel expander ORC system is one of the solutions for providing an additional power output by improving the partial-load performance of an ORC. The parallel expander system corresponds to partial-load conditions by switching between various combinations of the expanders. During this process, the dynamic behavior occurs, which have not been characterized well in the open literature according to the best of the authors’ knowledge. In this study, we developed a dynamic modeling of an ORC system using dual expanders (DE-ORC) to study the dynamic responses during its mode changes. System components were simulated using an open-source library of ThermoCycle written in Modelica language. For each component, empirical parameters were implemented based on the experimental results. Furthermore, during the mode change that involved going from dual expander mode to singular expander mode, and to prevent the formation of the droplet in the expanders, a control strategy was proposed and simulated. The strategy involved lowering of the mass flow rate and then shifting the mode. Several timings between flow rate lowering and shifting the mode were analyzed, and the optimum shifting time was found to be in between 40 to 50 s.
Open AccessDynamic Simulation of Partial Load Operation of an Organic Rankine Cycle with Two Parallel Expanders
The parallel expander ORC system is one of the solutions for providing an additional power output by improving the partial-load performance of an ORC. The parallel expander system corresponds to partial-load conditions by switching between various combinations of the expanders. During this process, the dynamic behavior occurs, which have not been characterized well in the open literature according to the best of the authors’ knowledge. In this study, we developed a dynamic modeling of an ORC system using dual expanders (DE-ORC) to study the dynamic responses during its mode changes. System components were simulated using an open-source library of ThermoCycle written in Modelica language. For each component, empirical parameters were implemented based on the experimental results. Furthermore, during the mode change that involved going from dual expander mode to singular expander mode, and to prevent the formation of the droplet in the expanders, a control strategy was proposed and simulated. The strategy involved lowering of the mass flow rate and then shifting the mode. Several timings between flow rate lowering and shifting the mode were analyzed, and the optimum shifting time was found to be in between 40 to 50 s.
- Open Access
Integrated Vapor Compression Chiller with Bottoming Organic Rankine Cycle and Onsite Low-Grade Renewable Energy
The present study offers a scheme to improve the performance of existing large-scale chillers. The system involves raising the temperature of the chiller’s cooling water stream using renewable energy sources by incorporating an organic Rankine cycle (ORC). The thermal analysis was conducted by raising the temperature of one-third of the approximately 200 ton chiller’s cooling water. The investigation was considered for ORC evaporator inlet temperature of 90~120 °C by the step of 10 °C. Various working fluids for the different ORC evaporator inlet temperatures were examined. Sensitivity analyses conducted on the degree of superheating, degree of subcooling, condenser saturation temperature, pinch point temperature differences of the ORC evaporator and condenser, and the mass flowrates of the heating and cooling streams were also reported. Genetic algorithm was employed to carry out the optimization. The best options for the ORC working fluid at the heating source ORC evaporator inlet temperatures of 90 °C was found to be DME, presenting an improvement of 48.72% in comparison with the rated coefficient of performance (COP) value of the VCC, with a renewable energy input requirement of 710 kW. At the heat source temperatures of 100 °C and 110 °C, butene, which presented an improvement in the COP equal to 48.76% and 68.85%, respectively, with the corresponding renewable energy requirements of 789.6 kW and 852 kW, was found to be the ideal candidate. Meanwhile, at the heat source inlet temperature of 120 °C, R1233zd (E), representing an improvement of 140.88% with the renewable energy input of around 1061 kW, was determined to be the most favorable ORC working fluid candidate.
Open AccessIntegrated Vapor Compression Chiller with Bottoming Organic Rankine Cycle and Onsite Low-Grade Renewable Energy
The present study offers a scheme to improve the performance of existing large-scale chillers. The system involves raising the temperature of the chiller’s cooling water stream using renewable energy sources by incorporating an organic Rankine cycle (ORC). The thermal analysis was conducted by raising the temperature of one-third of the approximately 200 ton chiller’s cooling water. The investigation was considered for ORC evaporator inlet temperature of 90~120 °C by the step of 10 °C. Various working fluids for the different ORC evaporator inlet temperatures were examined. Sensitivity analyses conducted on the degree of superheating, degree of subcooling, condenser saturation temperature, pinch point temperature differences of the ORC evaporator and condenser, and the mass flowrates of the heating and cooling streams were also reported. Genetic algorithm was employed to carry out the optimization. The best options for the ORC working fluid at the heating source ORC evaporator inlet temperatures of 90 °C was found to be DME, presenting an improvement of 48.72% in comparison with the rated coefficient of performance (COP) value of the VCC, with a renewable energy input requirement of 710 kW. At the heat source temperatures of 100 °C and 110 °C, butene, which presented an improvement in the COP equal to 48.76% and 68.85%, respectively, with the corresponding renewable energy requirements of 789.6 kW and 852 kW, was found to be the ideal candidate. Meanwhile, at the heat source inlet temperature of 120 °C, R1233zd (E), representing an improvement of 140.88% with the renewable energy input of around 1061 kW, was determined to be the most favorable ORC working fluid candidate.
- Open Access
Assessment of a District Trigeneration Biomass Powered Double Organic Rankine Cycle as Primed Mover and Supported Cooling
This study presents a combined cooling, heating, and power system powered by biogas, suitable for small scale communities in remote locations. To run such a system, in order to obtain the daily life essentials of electricity, hot water, and cooling, municipal waste can be considered as an option. Furthermore, the organic Rankine cycle part of the organic Rankine cycle powered vapor compression chiller can be used in times of need for additional electric production. The system comprises a medium temperature organic Rankine cycle utilizing M-xylene as its working fluid, and the cooling was covered by an Isobutane vapor compression cycle powered by an R245fa employing organic Rankine cycle. The system analyzed was designated to provide 250 kW of electricity. The energetic and exergetic analysis was performed, considering several system design parameters. The impact of the design parameters in the prime mover has a much greater effect on the whole system. The system proposed can deliver cooling values at the rate between 9.19 and 22 kW and heating values ranging from 879 up to 1255 kW, depending on the design parameter. Furthermore, the second law efficiency of the system was found to be approximately 56% at the baseline conditions and can be increased to 64.5%.
Open AccessAssessment of a District Trigeneration Biomass Powered Double Organic Rankine Cycle as Primed Mover and Supported Cooling
This study presents a combined cooling, heating, and power system powered by biogas, suitable for small scale communities in remote locations. To run such a system, in order to obtain the daily life essentials of electricity, hot water, and cooling, municipal waste can be considered as an option. Furthermore, the organic Rankine cycle part of the organic Rankine cycle powered vapor compression chiller can be used in times of need for additional electric production. The system comprises a medium temperature organic Rankine cycle utilizing M-xylene as its working fluid, and the cooling was covered by an Isobutane vapor compression cycle powered by an R245fa employing organic Rankine cycle. The system analyzed was designated to provide 250 kW of electricity. The energetic and exergetic analysis was performed, considering several system design parameters. The impact of the design parameters in the prime mover has a much greater effect on the whole system. The system proposed can deliver cooling values at the rate between 9.19 and 22 kW and heating values ranging from 879 up to 1255 kW, depending on the design parameter. Furthermore, the second law efficiency of the system was found to be approximately 56% at the baseline conditions and can be increased to 64.5%.