Yao Gao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yao Gao has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
- Wei Hang
Department of Chemistry, College of Chemistry and Chemical Engineering, Xiamen University, and Discipline of Intelligent Instrument and Equipment
8 shared publications Lin Lin
Department of Chemistry, Key Laboratory of Analytical Sciences, College of Chemistry and Chemical Engineering, Chemical Engineering, Xiamen University 361005, China
7 shared publicationsXiaomei Yan
Department of Chemistry, Key Laboratory of Analytical Sciences College of Chemistry and Chemical Engineering Xiamen University Xiamen China
5 shared publicationsZhenzhen Huang
Department of Chemistry, Key Laboratory of Analytical Sciences College of Chemistry and Chemical Engineering Xiamen University Xiamen China
5 shared publicationsJinchun Xing
Department of Urology Xiamen First Hospital Xiamen China
4 shared publicationsTianwen Zhang
Fujian Fishery Resources Monitoring Center, Fuzhou 350003, Fujian, China
4 shared publications
Latest Publications
- 23 February 2026
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 274, 117440
Simultaneous quantification of fat- and water-soluble vitamins in serum by valve-mediated dual LC-MS/MS
- 23 February 2026
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 274, 117440
Simultaneous quantification of fat- and water-soluble vitamins in serum by valve-mediated dual LC-MS/MS
- Open Access
- 19 November 2023
- Published by Elsevier in International Immunopharmacology
- Vol. 126, 111202
Downregulation of Gadd45β alleviates osteoarthritis by repressing lipopolysaccharide-induced fibroblast-like synoviocyte inflammation, proliferation and migration
- 19 November 2023
- Published by Elsevier in International Immunopharmacology
- Vol. 126, 111202
Open AccessDownregulation of Gadd45β alleviates osteoarthritis by repressing lipopolysaccharide-induced fibroblast-like synoviocyte inflammation, proliferation and migration
- Open Access
Diagnostic biomarker panels of osteoarthritis: UPLC-QToF/MS-based serum metabolic profiling
Osteoarthritis (OA) is the most common joint disease in the world, characterized by pain and loss of joint function, which has led to a serious reduction in the quality of patients’ lives. In this work, ultrahigh performance liquid chromatography coupled with quadrupole time-of-flight tandem mass spectrometry (UPLC-QToF/MS) in conjunction with multivariate pattern recognition methods and an univariate statistical analysis scheme were applied to explore the serum metabolic signatures within OA group (n = 31), HC (healthy controls) group (n = 57) and non-OA group (n = 19) for early diagnosis and differential diagnosis of OA. Based on logistic regression analysis and receiver operating characteristic (ROC) curve analysis, seven metabolites, including phosphatidylcholine (18:0/22:6), p-cresol sulfate and so on, were identified as critical metabolites for the diagnosis of OA and HC and yielded an area under the curve (AUC) of 0.978. The other panel of unknown m/z 239.091, phosphatidylcholine (18:0/18:0) and phenylalanine were found to distinguish OA from non-OA and achieved an AUC of 0.888. These potential biomarkers are mainly involved in lipid metabolism, glucose metabolism and amino acid metabolism. It is expected to reveal new insight into OA pathogenesis from changed metabolic pathways.
Open AccessDiagnostic biomarker panels of osteoarthritis: UPLC-QToF/MS-based serum metabolic profiling
Osteoarthritis (OA) is the most common joint disease in the world, characterized by pain and loss of joint function, which has led to a serious reduction in the quality of patients’ lives. In this work, ultrahigh performance liquid chromatography coupled with quadrupole time-of-flight tandem mass spectrometry (UPLC-QToF/MS) in conjunction with multivariate pattern recognition methods and an univariate statistical analysis scheme were applied to explore the serum metabolic signatures within OA group (n = 31), HC (healthy controls) group (n = 57) and non-OA group (n = 19) for early diagnosis and differential diagnosis of OA. Based on logistic regression analysis and receiver operating characteristic (ROC) curve analysis, seven metabolites, including phosphatidylcholine (18:0/22:6), p-cresol sulfate and so on, were identified as critical metabolites for the diagnosis of OA and HC and yielded an area under the curve (AUC) of 0.978. The other panel of unknown m/z 239.091, phosphatidylcholine (18:0/18:0) and phenylalanine were found to distinguish OA from non-OA and achieved an AUC of 0.888. These potential biomarkers are mainly involved in lipid metabolism, glucose metabolism and amino acid metabolism. It is expected to reveal new insight into OA pathogenesis from changed metabolic pathways.
- Open Access
- 18 June 2021
- Published by Springer Nature in Research Square
Diagnostic biomarkers for USD via serum and urinary amino acid profiles using a metabolomics-based strategy
Background: Urinary stone disease (USD) is a common disease with a high prevalence, a high recurrence rate and a lack of effective diagnostic biomarkers.Methods: To explore the potential biomarkers for USD early diagnosis, the serum and urinary amino acid (AA) profiles of 74 USD patients were compared with 35 healthy controls (HC) via gas chromatography coupled with mass spectrometry (GC-MS).Results: Based on the serum and urinary AA profiles analyzed by metabolomic strategy, a group of 5 differentially expressed AAs including Ser, Glu, Asp, Ile and Gly and 7 metabolic pathway disorders in patients were revealed.Conclusions: These serum and urinary AA profiles could provided clinical biomarkers for USD early diagnosis, and also indicated that some specific AA metabolic pathways might play important roles in the pathogenesis of USD.
- 18 June 2021
- Published by Springer Nature in Research Square
Open AccessDiagnostic biomarkers for USD via serum and urinary amino acid profiles using a metabolomics-based strategy
Background: Urinary stone disease (USD) is a common disease with a high prevalence, a high recurrence rate and a lack of effective diagnostic biomarkers.Methods: To explore the potential biomarkers for USD early diagnosis, the serum and urinary amino acid (AA) profiles of 74 USD patients were compared with 35 healthy controls (HC) via gas chromatography coupled with mass spectrometry (GC-MS).Results: Based on the serum and urinary AA profiles analyzed by metabolomic strategy, a group of 5 differentially expressed AAs including Ser, Glu, Asp, Ile and Gly and 7 metabolic pathway disorders in patients were revealed.Conclusions: These serum and urinary AA profiles could provided clinical biomarkers for USD early diagnosis, and also indicated that some specific AA metabolic pathways might play important roles in the pathogenesis of USD.
- Open Access
- 16 February 2021
- Published by PeerJ in PeerJ Analytical Chemistry
- Vol. 3, e8
Screening of 49 antibiotic residues in aquatic products using modified QuEChERS sample preparation and UPLC-QToFMS analysis
A precise analytical method was established for rapid screening of 49 antibiotic residues in aquatic products by ultra-high performance liquid chromatography-quadrupole time of flight mass spectrometry (UPLC-QToFMS). The quick, easy, cheap, effective, rugged and safe (QuEChERS) process was refined for effective sample preparation. The homogenized samples of aquatic products were extracted with 3% acetic acid in acetonitrile, salted out with anhydrous magnesium sulfate and sodium chloride, and cleaned up by octadecylsilane (C18) and primary-secondary amine (PSA) powder. Then, the purified samples were separated on a BEH C18 column using 0.1% formic acid and methanol as mobile phases by gradient elution, detected by MS under positive Electron Spray Ionization (ESI+) mode. The linear range of matrix-matched calibration curve was 1–100 μg/L for each compound with the correlation coefficients in the range of 0.9851–0.9999. The recoveries of target antibiotics at the different spiked levels ranged from 60.2% to 117.9% except for lincomycin hydrochloride, whereas relative standard deviations (RSDs) were between 1.6% and 14.0% except for sulfaguanidine in grass Carp, Penaeus vannamei and Scylla serrata matrices. The limits of detection (LODs) (S/N = 3) for the analytes were 0.05–2.40 μg/kg, 0.08–2.00 μg/kg and 0.10–2.27 μg/kg and the limits of quantification (LOQs) (S/N = 10) were 0.16–8.00 μg/kg, 0.25–6.66 μg/kg and 0.32–7.56 μg/kg in grass Carp, Penaeus vannamei and Scylla serrata, respectively. The method was successfully applied to grass Carp, Penaeus vannamei and Scylla serrata, demonstrating its ability for the determination of multi-categories antibiotic residues in aquatic products.
- 16 February 2021
- Published by PeerJ in PeerJ Analytical Chemistry
- Vol. 3, e8
Open AccessScreening of 49 antibiotic residues in aquatic products using modified QuEChERS sample preparation and UPLC-QToFMS analysis
A precise analytical method was established for rapid screening of 49 antibiotic residues in aquatic products by ultra-high performance liquid chromatography-quadrupole time of flight mass spectrometry (UPLC-QToFMS). The quick, easy, cheap, effective, rugged and safe (QuEChERS) process was refined for effective sample preparation. The homogenized samples of aquatic products were extracted with 3% acetic acid in acetonitrile, salted out with anhydrous magnesium sulfate and sodium chloride, and cleaned up by octadecylsilane (C18) and primary-secondary amine (PSA) powder. Then, the purified samples were separated on a BEH C18 column using 0.1% formic acid and methanol as mobile phases by gradient elution, detected by MS under positive Electron Spray Ionization (ESI+) mode. The linear range of matrix-matched calibration curve was 1–100 μg/L for each compound with the correlation coefficients in the range of 0.9851–0.9999. The recoveries of target antibiotics at the different spiked levels ranged from 60.2% to 117.9% except for lincomycin hydrochloride, whereas relative standard deviations (RSDs) were between 1.6% and 14.0% except for sulfaguanidine in grass Carp, Penaeus vannamei and Scylla serrata matrices. The limits of detection (LODs) (S/N = 3) for the analytes were 0.05–2.40 μg/kg, 0.08–2.00 μg/kg and 0.10–2.27 μg/kg and the limits of quantification (LOQs) (S/N = 10) were 0.16–8.00 μg/kg, 0.25–6.66 μg/kg and 0.32–7.56 μg/kg in grass Carp, Penaeus vannamei and Scylla serrata, respectively. The method was successfully applied to grass Carp, Penaeus vannamei and Scylla serrata, demonstrating its ability for the determination of multi-categories antibiotic residues in aquatic products.
- 1 October 2018
- Published by Elsevier in Veterinary Microbiology
- Vol. 224, 34-42
Influence of outer membrane vesicles of Proteus mirabilis isolated from boar semen on sperm function
- 1 October 2018
- Published by Elsevier in Veterinary Microbiology
- Vol. 224, 34-42
Influence of outer membrane vesicles of Proteus mirabilis isolated from boar semen on sperm function
- 26 February 2018
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 10 (13) , 1552-1559
An ultrasensitive fluorescence aptasensor for carcino-embryonic antigen detection based on fluorescence resonance energy transfer from upconversion phosphors to Au nanoparticles
A novel fluorescence resonance energy transfer (FRET)-based aptasensor was proposed for carcino-embryonic antigen (CEA) detection utilizing NaYF4:Yb3+, Er3+ upconversion nanoparticles (UCNPs) and gold nanoparticles (Au-NPs) as the energy donor and acceptor, respectively. The FRET process occurs when the single-stranded DNA modified UCNPs and Au-NPs are linked together by the CEA aptamer, which leads to the fluorescence quenching of UCNPs. However, the presence of CEA splits the above fluorescence-suppressed Au-NPs–aptamer–UCNPs sandwich complex, resulting in the fluorescence recovery of UCNPs. The recovery of fluorescence intensity is linearly correlated to the concentration of CEA in the range of 0.05–2.0 ng mL−1, enabling the detection and quantification of CEA. Such a sandwich-type FRET-based assay possesses a low limit of detection (0.02 ng mL−1) and satisfactory selectivity and reproducibility, indicating that this biosensor is applicable for the trace detection of the CEA protein.
- 26 February 2018
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 10 (13) , 1552-1559
An ultrasensitive fluorescence aptasensor for carcino-embryonic antigen detection based on fluorescence resonance energy transfer from upconversion phosphors to Au nanoparticles
A novel fluorescence resonance energy transfer (FRET)-based aptasensor was proposed for carcino-embryonic antigen (CEA) detection utilizing NaYF4:Yb3+, Er3+ upconversion nanoparticles (UCNPs) and gold nanoparticles (Au-NPs) as the energy donor and acceptor, respectively. The FRET process occurs when the single-stranded DNA modified UCNPs and Au-NPs are linked together by the CEA aptamer, which leads to the fluorescence quenching of UCNPs. However, the presence of CEA splits the above fluorescence-suppressed Au-NPs–aptamer–UCNPs sandwich complex, resulting in the fluorescence recovery of UCNPs. The recovery of fluorescence intensity is linearly correlated to the concentration of CEA in the range of 0.05–2.0 ng mL−1, enabling the detection and quantification of CEA. Such a sandwich-type FRET-based assay possesses a low limit of detection (0.02 ng mL−1) and satisfactory selectivity and reproducibility, indicating that this biosensor is applicable for the trace detection of the CEA protein.
- 18 April 2013
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 85 (9) , 4268-4272
Single-Cell Elemental Analysis via High Irradiance Femtosecond Laser Ionization Time-of-Flight Mass Spectrometry
In modern bioanalytics, elemental analysis of single cells is important yet challenging due to the complicated biological matrices and elemental contents. We have developed the high irradiance femtosecond laser ionization orthogonal time-of-flight mass spectrometry (fs-LI-O-TOFMS) to determine the elemental composition of individual cells. The sample preparation procedure is simple and fast through heating and drying the cells. Under typical operating conditions, elements above femtogram levels in a single cell can be clearly observed in the spectrum with reasonable isotope ratios. Some of the nonmetallic elements that are difficult to measure by ICPMS, such as P, S, and Cl, can be easily determined by fs-LI-O-TOFMS. Replicate analyses show that signal variations are 15–35% for metallic elements and 25–50% for nonmetallic elements. The results demonstrate that fs-LI-O-TOFMS is a simple, rapid, and practical tool for the elemental determination of single cells.
- 18 April 2013
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 85 (9) , 4268-4272
Single-Cell Elemental Analysis via High Irradiance Femtosecond Laser Ionization Time-of-Flight Mass Spectrometry
In modern bioanalytics, elemental analysis of single cells is important yet challenging due to the complicated biological matrices and elemental contents. We have developed the high irradiance femtosecond laser ionization orthogonal time-of-flight mass spectrometry (fs-LI-O-TOFMS) to determine the elemental composition of individual cells. The sample preparation procedure is simple and fast through heating and drying the cells. Under typical operating conditions, elements above femtogram levels in a single cell can be clearly observed in the spectrum with reasonable isotope ratios. Some of the nonmetallic elements that are difficult to measure by ICPMS, such as P, S, and Cl, can be easily determined by fs-LI-O-TOFMS. Replicate analyses show that signal variations are 15–35% for metallic elements and 25–50% for nonmetallic elements. The results demonstrate that fs-LI-O-TOFMS is a simple, rapid, and practical tool for the elemental determination of single cells.
- 1 September 2012
- Published by Elsevier in Chinese Journal of Analytical Chemistry
- Vol. 40 (9) , 1322-1328
A Study of Human Bladder Cancer by Serum and Urine Metabonomics
- 1 September 2012
- Published by Elsevier in Chinese Journal of Analytical Chemistry
- Vol. 40 (9) , 1322-1328
A Study of Human Bladder Cancer by Serum and Urine Metabonomics
- 11 June 2012
- Published by Wiley in Proteomics
- Vol. 12 (14) , 2238-2246
LC‐MS‐based serum metabolic profiling for genitourinary cancer classification and cancer type‐specific biomarker discovery
Bladder cancer (BC) and kidney cancer (KC) are the first two commonly occurring genitourinary cancers in China. In this study, a comprehensive LC‐MS‐based method, which utilizes both reversed phase liquid chromatography (RPLC) and hydrophilic interaction chromatography (HILIC) separations, has been carried out in conjunction with multivariate data analysis to discriminate the global serum profiles of BC, KC, and noncancer controls. An independent test set consisting of different patients has been used to objectively evaluate the predictive ability of the analysis platform. Excellent sensitivity and specificity have been achieved in detection of KC and BC. The results suggest that serum metabolic profiling could be used for different types of genitourinary cancer diagnosis. Furthermore, cancer type‐specific biomarkers were found through a critical selection criterion. As a result, eicosatrienol, azaprostanoic acid, docosatrienol, retinol, and 14′‐apo‐beta‐carotenal were found as specific biomarkers for BC; and PE(P‐16:0e/0:0), glycerophosphorylcholine, ganglioside GM3 (d18:1/22:1), C17 sphinganine, and SM(d18:0/16:1(9Z)) were found as specific biomarkers for KC. Receiver operating characteristic (ROC) analysis was used for the preliminary evaluation of the biomarkers. These biomarkers have great potential to be used in the clinical diagnosis after further rigorous assessment.
- 11 June 2012
- Published by Wiley in Proteomics
- Vol. 12 (14) , 2238-2246
LC‐MS‐based serum metabolic profiling for genitourinary cancer classification and cancer type‐specific biomarker discovery
Bladder cancer (BC) and kidney cancer (KC) are the first two commonly occurring genitourinary cancers in China. In this study, a comprehensive LC‐MS‐based method, which utilizes both reversed phase liquid chromatography (RPLC) and hydrophilic interaction chromatography (HILIC) separations, has been carried out in conjunction with multivariate data analysis to discriminate the global serum profiles of BC, KC, and noncancer controls. An independent test set consisting of different patients has been used to objectively evaluate the predictive ability of the analysis platform. Excellent sensitivity and specificity have been achieved in detection of KC and BC. The results suggest that serum metabolic profiling could be used for different types of genitourinary cancer diagnosis. Furthermore, cancer type‐specific biomarkers were found through a critical selection criterion. As a result, eicosatrienol, azaprostanoic acid, docosatrienol, retinol, and 14′‐apo‐beta‐carotenal were found as specific biomarkers for BC; and PE(P‐16:0e/0:0), glycerophosphorylcholine, ganglioside GM3 (d18:1/22:1), C17 sphinganine, and SM(d18:0/16:1(9Z)) were found as specific biomarkers for KC. Receiver operating characteristic (ROC) analysis was used for the preliminary evaluation of the biomarkers. These biomarkers have great potential to be used in the clinical diagnosis after further rigorous assessment.