Yasuki Motozawa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yasuki Motozawa has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Masahito Hitosugi
Department of Legal Medicine, Shiga University of Medical Science, Shiga 520-2192, Japan
3 shared publications - Katsunori Tanaka
Department of Legal Medicine, Shiga University of Medical Science, Otsu 520-2192, Japan
2 shared publications - Kentaro Takahashi
Hino Memorial Hospital, Hino 529-1642, Japan
2 shared publications - Tetsuo Maki
Department of Mechanical Engineering, Tokyo City University, Tokyo 158-8557, Japan
2 shared publications - Arisa Takeda
Department of Legal Medicine, Shiga University of Medical Science, Tsukinowa, Seta, Otsu 520-2192, Shiga, Japan
1 shared publication - Haruo Murayama
Dokkyo Medical University, Shimotsuga, Japan
1 shared publication
Latest Publications
- Open Access
- 26 October 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (21) , 13905
Severity of Placental Abruption in Restrained Pregnant Vehicle Drivers: Correct Seat Belt Use Confirmed by Finite Element Model Analysis
Despite wearing a seat belt, pregnant drivers often suffer from negative fetal outcomes in the event of motor accidents. In order to maintain the safety of pregnant drivers and their fetuses, we assessed the severity of placental abruption caused by motor vehicle collisions using computer simulations. We employed a validated pregnant finite element model to determine the area of placental abruption. We investigated frontal vehicle collisions with a speed of 40 km/h or less involving restrained pregnant drivers with a gestational age of 30 weeks. For a crash speed of 40 km/h, the placental abruption area was 7.0% with a correctly positioned lap belt across the lower abdomen; it was 36.3% with the belt positioned at the umbilicus. The area of placental abruption depended on collision speed, but we found that with a correctly positioned belt it likely would not lead to negative fetal outcomes. We examined the effects on placental abruptions of reconfiguring seat belt width and force limiter setting. A wider lap belt and lower force limiter setting reduced the area of placental abruption to 3.5% and 1.1%, respectively; however, they allowed more forward movement upon collision. A 2.5 kN force limiter setting may be appropriate with respect to both forward movement and reduced placental abruption area. This study confirmed the importance of correctly using seat belts for pregnant drivers. It provides valuable evidence about improving safety equipment settings.
- 26 October 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (21) , 13905
Open AccessSeverity of Placental Abruption in Restrained Pregnant Vehicle Drivers: Correct Seat Belt Use Confirmed by Finite Element Model Analysis
Despite wearing a seat belt, pregnant drivers often suffer from negative fetal outcomes in the event of motor accidents. In order to maintain the safety of pregnant drivers and their fetuses, we assessed the severity of placental abruption caused by motor vehicle collisions using computer simulations. We employed a validated pregnant finite element model to determine the area of placental abruption. We investigated frontal vehicle collisions with a speed of 40 km/h or less involving restrained pregnant drivers with a gestational age of 30 weeks. For a crash speed of 40 km/h, the placental abruption area was 7.0% with a correctly positioned lap belt across the lower abdomen; it was 36.3% with the belt positioned at the umbilicus. The area of placental abruption depended on collision speed, but we found that with a correctly positioned belt it likely would not lead to negative fetal outcomes. We examined the effects on placental abruptions of reconfiguring seat belt width and force limiter setting. A wider lap belt and lower force limiter setting reduced the area of placental abruption to 3.5% and 1.1%, respectively; however, they allowed more forward movement upon collision. A 2.5 kN force limiter setting may be appropriate with respect to both forward movement and reduced placental abruption area. This study confirmed the importance of correctly using seat belts for pregnant drivers. It provides valuable evidence about improving safety equipment settings.
- Open Access
- 24 December 2021
- Published by MDPI AG in Healthcare
- Vol. 10 (1) , 27
Factors Affecting the Severity of Placental Abruption in Pregnant Vehicle Drivers: Analysis with a Novel Finite Element Model
We clarified factors affecting the severity of placental abruption in motor vehicle collisions by quantitively analyzing the area of placental abruption in a numerical simulation of an unrestrained pregnant vehicle driver at collision velocities of 3 and 6 m/s. For the simulation, we constructed a novel finite element model of a small 30-week pregnant woman, which was validated anthropometrically using computed tomography data and biomechanically using previous examinations of post-mortem human subjects. In the simulation, stress in the elements of the utero–placental interface was computed, and those elements exceeding a failure criterion were considered to be abrupted. It was found that a doubling of the collision velocity increased the area of placental abruption 10-fold, and the abruption area was approximately 20% for a collision velocity of 6 m/s, which is lower than the speed limit for general roads. This result implies that even low-speed vehicle collisions have negative maternal and fetal outcomes owing to placental abruption without a seatbelt restraint. Additionally, contact to the abdomen, 30 mm below the umbilicus, led to a larger placental abruption area than contact at the umbilicus level when the placenta was located at the uterus fundus. The results support that a reduction in the collision speed and seatbelt restraint at a suitable position are important to decrease the placental abruption area and therefore protect a pregnant woman and her fetus in a motor vehicle collision.
- 24 December 2021
- Published by MDPI AG in Healthcare
- Vol. 10 (1) , 27
Open AccessFactors Affecting the Severity of Placental Abruption in Pregnant Vehicle Drivers: Analysis with a Novel Finite Element Model
We clarified factors affecting the severity of placental abruption in motor vehicle collisions by quantitively analyzing the area of placental abruption in a numerical simulation of an unrestrained pregnant vehicle driver at collision velocities of 3 and 6 m/s. For the simulation, we constructed a novel finite element model of a small 30-week pregnant woman, which was validated anthropometrically using computed tomography data and biomechanically using previous examinations of post-mortem human subjects. In the simulation, stress in the elements of the utero–placental interface was computed, and those elements exceeding a failure criterion were considered to be abrupted. It was found that a doubling of the collision velocity increased the area of placental abruption 10-fold, and the abruption area was approximately 20% for a collision velocity of 6 m/s, which is lower than the speed limit for general roads. This result implies that even low-speed vehicle collisions have negative maternal and fetal outcomes owing to placental abruption without a seatbelt restraint. Additionally, contact to the abdomen, 30 mm below the umbilicus, led to a larger placental abruption area than contact at the umbilicus level when the placenta was located at the uterus fundus. The results support that a reduction in the collision speed and seatbelt restraint at a suitable position are important to decrease the placental abruption area and therefore protect a pregnant woman and her fetus in a motor vehicle collision.
- Open Access
- 16 February 2021
- Published by MDPI AG in Healthcare
- Vol. 9 (2) , 214
Biomechanical Analysis of Serious Neck Injuries Resulting from Judo
To establish a basis for initial diagnosis and for proposing preventive measures for the serious neck injuries occasionally experienced by judo practitioners, the biomechanical mechanisms of these injuries were analyzed. Two male judo experts repeatedly threw an anthropomorphic test device (POLAR dummy) using three throwing techniques (Seoi-nage, Osoto-gari, and Ouchi-gari). The dummy’s kinematic data were captured using a high-speed digital camera, and the load and moment of the neck were measured with load cells. The neck injury criterion (Nij) and beam criterion were also calculated. In Seoi-nage, the anterior and parietal regions of the dummy’s head contacted the tatami (judo mat). Subsequently, most of the body weight was applied, with the neck experiencing the highest compression. However, in Osoto-gari and Ouchi-gari, the occipital region of the dummy’s head contacted the tatami. Significantly higher values of both Nij (median 0.68) and beam criterion (median 0.90) corresponding to a 34.7% to 37.1% risk of neck injury with an abbreviated injury scale score ≥2 were shown in Seoi-nage than in either Ouchi-gari or Osoto-gari. In judo, when thrown by the Seoi-nage technique, serious neck injuries can occur as a result of neck compression that occurs when the head contacts the ground.
- 16 February 2021
- Published by MDPI AG in Healthcare
- Vol. 9 (2) , 214
Open AccessBiomechanical Analysis of Serious Neck Injuries Resulting from Judo
To establish a basis for initial diagnosis and for proposing preventive measures for the serious neck injuries occasionally experienced by judo practitioners, the biomechanical mechanisms of these injuries were analyzed. Two male judo experts repeatedly threw an anthropomorphic test device (POLAR dummy) using three throwing techniques (Seoi-nage, Osoto-gari, and Ouchi-gari). The dummy’s kinematic data were captured using a high-speed digital camera, and the load and moment of the neck were measured with load cells. The neck injury criterion (Nij) and beam criterion were also calculated. In Seoi-nage, the anterior and parietal regions of the dummy’s head contacted the tatami (judo mat). Subsequently, most of the body weight was applied, with the neck experiencing the highest compression. However, in Osoto-gari and Ouchi-gari, the occipital region of the dummy’s head contacted the tatami. Significantly higher values of both Nij (median 0.68) and beam criterion (median 0.90) corresponding to a 34.7% to 37.1% risk of neck injury with an abbreviated injury scale score ≥2 were shown in Seoi-nage than in either Ouchi-gari or Osoto-gari. In judo, when thrown by the Seoi-nage technique, serious neck injuries can occur as a result of neck compression that occurs when the head contacts the ground.