J. Buermans
Research Subjects
J. Buermans has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Andrei Goriaev
Laboratory for Plasma Physics, LPP-ERM/KMS, Brussels, Belgium
7 shared publications - D. López-Rodríguez
Laboratory for Plasma Physics, LPP-ERM/KMS, Brussels, Belgium
7 shared publications - Kristel Crombe
Applied Physics, Ghent University, Sint Pietersnieuwstraat 41B4, Gent, 9000, BELGIUM
7 shared publications - Per Petersson
KTH Royal Institute of Technology, Stockholm, Sweden
7 shared publications - Yurii V. Kovtun
Institute of Plasma Physics of the National Science Center “Kharkiv Institute of Physics and Technology
7 shared publications - Sebastijan Brezinsek
Forschungszentrum Jülich
6 shared publications
Latest Publications
- 5 November 2025
- Published by Springer Nature in Journal of Fusion Energy
- Vol. 44 (2) , 1-9
Сombined Glow + Microwave Discharges in the TOMAS Plasma Facility
- 5 November 2025
- Published by Springer Nature in Journal of Fusion Energy
- Vol. 44 (2) , 1-9
Сombined Glow + Microwave Discharges in the TOMAS Plasma Facility
- Open Access
- 1 March 2025
- Published by AIP Publishing in Physics of Plasmas
- Vol. 32 (3)
Combined electron cyclotron resonance and radio frequency discharges in the TOMAS facility
The experiments carried out in hydrogen at the TOMAS facility show the possibility of controlling plasma parameters such as temperature and electron density in a combined electron cyclotron resonance and radio frequency (ECR+RF) discharge. A maximum plasma density of up to ≈6 × 1016 m−3 and electron temperature of up to 35 eV are observed in the combined ECR+RF discharge. The propagation of RF waves in hydrogen plasma under a weak magnetic field is analyzed. Depending on RF frequency and experimental conditions, such as radial distribution of plasma density and magnetic field, there can be several cases: only the slow wave can propagate, simultaneously slow and fast waves can propagate, or only the fast wave can propagate. The injection of additional RF power into the ECR discharge allows us to change the flux of neutral particles and their distribution function. Even the injection of small RF power of ≈ 0.26 kW relative to microwave power of ≈ 1.7 kW leads to an increase in the hydrogen flux by a factor of ∼2.5. At RF power PRF ≈ 1.57 kW, the H0 flux increases by a factor of ∼9.3. The ability to control the fluxes and energies of particles leaving the plasma volume is important to approach the conditions necessary to study plasma–surface interactions in wall conditioning and fusion edge plasmas.
- 1 March 2025
- Published by AIP Publishing in Physics of Plasmas
- Vol. 32 (3)
Open AccessCombined electron cyclotron resonance and radio frequency discharges in the TOMAS facility
The experiments carried out in hydrogen at the TOMAS facility show the possibility of controlling plasma parameters such as temperature and electron density in a combined electron cyclotron resonance and radio frequency (ECR+RF) discharge. A maximum plasma density of up to ≈6 × 1016 m−3 and electron temperature of up to 35 eV are observed in the combined ECR+RF discharge. The propagation of RF waves in hydrogen plasma under a weak magnetic field is analyzed. Depending on RF frequency and experimental conditions, such as radial distribution of plasma density and magnetic field, there can be several cases: only the slow wave can propagate, simultaneously slow and fast waves can propagate, or only the fast wave can propagate. The injection of additional RF power into the ECR discharge allows us to change the flux of neutral particles and their distribution function. Even the injection of small RF power of ≈ 0.26 kW relative to microwave power of ≈ 1.7 kW leads to an increase in the hydrogen flux by a factor of ∼2.5. At RF power PRF ≈ 1.57 kW, the H0 flux increases by a factor of ∼9.3. The ability to control the fluxes and energies of particles leaving the plasma volume is important to approach the conditions necessary to study plasma–surface interactions in wall conditioning and fusion edge plasmas.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Characterization of plasma parameters and neutral particles in microwave and radio frequency discharges in the Toroidal Magnetized System
A characterization of plasma parameters and neutral particle energies and fluxes has been performed for radio frequency and microwave discharges in the Toroidal Magnetized System (TOMAS). A movable triple Langmuir probe was used to study the electron densities and temperatures, and a time-of-flight neutral particle analyzer was used to measure the energy and fluxes of neutral particles, as a function of the total injected power and the antenna frequency used to generate the plasma. The experimental results can provide information on the behavior of neutral particles at low energies in wall conditioning plasmas.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Characterization of plasma parameters and neutral particles in microwave and radio frequency discharges in the Toroidal Magnetized System
A characterization of plasma parameters and neutral particle energies and fluxes has been performed for radio frequency and microwave discharges in the Toroidal Magnetized System (TOMAS). A movable triple Langmuir probe was used to study the electron densities and temperatures, and a time-of-flight neutral particle analyzer was used to measure the energy and fluxes of neutral particles, as a function of the total injected power and the antenna frequency used to generate the plasma. The experimental results can provide information on the behavior of neutral particles at low energies in wall conditioning plasmas.
- Open Access
- 12 July 2024
- Published by IOP Publishing in Physica Scripta
- Vol. 99 (8) , 085606
Study of the Electron cyclotron power deposition in TOMAS
Efficient Electron Cyclotron Resonance Heating (ECRH) breakdown and pre-ionization can be achieved with fundamental X-mode, while higher harmonics can introduce excessive stray radiation. Fundamental heating however is characterized by a low cut-off density, introducing additional power absorption mechanisms in the plasma. A good knowledge of these mechanisms is necessary to use fundamental X-mode as an efficient pre-ionization method. Numerous experiments were performed on the TOroidally MAgnetized System (TOMAS) to study the power deposition for ECRH in helium. It is a facility designed to study plasma production, wall conditioning and plasma-surface interactions and is operated by LPP-ERM/KMS at the FZ-Jülich. The influence of the injected power P EC and the magnetic field B 0 on the absorption mechanisms is examined, in order to reduce stray radiation and improve the absorption efficiency. This will allow to determine the best scenarios for plasma start-up and pre-ionization.
- 12 July 2024
- Published by IOP Publishing in Physica Scripta
- Vol. 99 (8) , 085606
Open AccessStudy of the Electron cyclotron power deposition in TOMAS
Efficient Electron Cyclotron Resonance Heating (ECRH) breakdown and pre-ionization can be achieved with fundamental X-mode, while higher harmonics can introduce excessive stray radiation. Fundamental heating however is characterized by a low cut-off density, introducing additional power absorption mechanisms in the plasma. A good knowledge of these mechanisms is necessary to use fundamental X-mode as an efficient pre-ionization method. Numerous experiments were performed on the TOroidally MAgnetized System (TOMAS) to study the power deposition for ECRH in helium. It is a facility designed to study plasma production, wall conditioning and plasma-surface interactions and is operated by LPP-ERM/KMS at the FZ-Jülich. The influence of the injected power P EC and the magnetic field B 0 on the absorption mechanisms is examined, in order to reduce stray radiation and improve the absorption efficiency. This will allow to determine the best scenarios for plasma start-up and pre-ionization.
- Open Access
- 1 May 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (5)
Characterization of ECRH plasmas in TOMAS
To improve the plasma performance and control the density and plasma quality during the flat top phase, wall conditioning techniques are used in large fusion devices like W7-X and in JT60-SA. To study the performance of electron cyclotron wall conditioning, numerous experiments were performed on the TOroidally MAgnetized System, which is operated by LPP-ERM/KMS at the FZ-Jülich. It is a facility designed to study plasma production, wall conditioning, and plasma–surface interactions. The produced electron cyclotron resonance heating plasmas are characterized in various conditions by density and temperature measurements using a movable triple Langmuir probe in the horizontal and the vertical direction, complemented by video and spectroscopic data, to obtain a 2D extrapolation of the plasma parameters in the machine. A way to calibrate the triple Langmuir probe measurements is also investigated. These data can be used to determine the direction of the plasma drift in the vessel and identify the power absorption mechanisms. This will give more insight in the plasma behavior and improve the efficiency of wall conditioning and sample exposure experiments.
- 1 May 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (5)
Open AccessCharacterization of ECRH plasmas in TOMAS
To improve the plasma performance and control the density and plasma quality during the flat top phase, wall conditioning techniques are used in large fusion devices like W7-X and in JT60-SA. To study the performance of electron cyclotron wall conditioning, numerous experiments were performed on the TOroidally MAgnetized System, which is operated by LPP-ERM/KMS at the FZ-Jülich. It is a facility designed to study plasma production, wall conditioning, and plasma–surface interactions. The produced electron cyclotron resonance heating plasmas are characterized in various conditions by density and temperature measurements using a movable triple Langmuir probe in the horizontal and the vertical direction, complemented by video and spectroscopic data, to obtain a 2D extrapolation of the plasma parameters in the machine. A way to calibrate the triple Langmuir probe measurements is also investigated. These data can be used to determine the direction of the plasma drift in the vessel and identify the power absorption mechanisms. This will give more insight in the plasma behavior and improve the efficiency of wall conditioning and sample exposure experiments.
- Open Access
- 1 May 2023
- Published by AIP Publishing in AIP Advances
- Vol. 13 (5)
Triple Langmuir probe calibration in TOMAS ECRH plasma
In the TOMAS device, a triple Langmuir probe is used to measure the electron temperature and density. The accuracy of this measurement depends on correct determination of the effective collecting area of the probe, which depends on complex plasma transport processes. The probe can be calibrated by electron cyclotron resonance heating experiments using the cut-off density of the ordinary wave (O-wave). This threshold only depends on the frequency of the injected wave, and the occurrence of this phenomenon is clearly visible in the temperature evolution. The value of density is consequently known at this point and can be used to calibrate the density measurements of the triple Langmuir probe.
- 1 May 2023
- Published by AIP Publishing in AIP Advances
- Vol. 13 (5)
Open AccessTriple Langmuir probe calibration in TOMAS ECRH plasma
In the TOMAS device, a triple Langmuir probe is used to measure the electron temperature and density. The accuracy of this measurement depends on correct determination of the effective collecting area of the probe, which depends on complex plasma transport processes. The probe can be calibrated by electron cyclotron resonance heating experiments using the cut-off density of the ordinary wave (O-wave). This threshold only depends on the frequency of the injected wave, and the occurrence of this phenomenon is clearly visible in the temperature evolution. The value of density is consequently known at this point and can be used to calibrate the density measurements of the triple Langmuir probe.
- 12 November 2021
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 63 (12) , 125023
Comparative analysis of the plasma parameters of ECR and combined ECR + RF discharges in the TOMAS plasma facility
The toroidal magnetized system (TOMAS) plasma facility aims at complementary research on wall conditioning methods, plasma production and plasma–surface interaction studies. This paper explores for the first time the parameters in helium electron-cyclotron resonance (ECR) plasma and combined ECR + radio-frequency (RF) discharges in TOMAS. The ECR discharge in this work, at 2.45 GHz and 87.6 mT, is the main one for creating and maintaining the plasma, while the addition of RF power at 25 MHz allows to broaden the achievable electron temperature and density at a given gas flow, as evidenced by triple Langmuir probe measurements. This effect of the combined ECR + RF discharge provides flexibility to study particular aspects of wall conditioning techniques relevant to larger devices, or to approach plasma conditions relevant to fusion edge plasmas for particular surface interaction studies.
- 12 November 2021
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 63 (12) , 125023
Comparative analysis of the plasma parameters of ECR and combined ECR + RF discharges in the TOMAS plasma facility
The toroidal magnetized system (TOMAS) plasma facility aims at complementary research on wall conditioning methods, plasma production and plasma–surface interaction studies. This paper explores for the first time the parameters in helium electron-cyclotron resonance (ECR) plasma and combined ECR + radio-frequency (RF) discharges in TOMAS. The ECR discharge in this work, at 2.45 GHz and 87.6 mT, is the main one for creating and maintaining the plasma, while the addition of RF power at 25 MHz allows to broaden the achievable electron temperature and density at a given gas flow, as evidenced by triple Langmuir probe measurements. This effect of the combined ECR + RF discharge provides flexibility to study particular aspects of wall conditioning techniques relevant to larger devices, or to approach plasma conditions relevant to fusion edge plasmas for particular surface interaction studies.
- 1 February 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (2) , 023506
The upgraded TOMAS device: A toroidal plasma facility for wall conditioning, plasma production, and plasma–surface interaction studies
The Toroidal Magnetized System device has been significantly upgraded to enable development of various wall conditioning techniques, including methods based on ion and electron cyclotron (IC/EC) range of frequency plasmas, and to complement plasma–wall interaction research in tokamaks and stellarators. The toroidal magnetic field generated by 16 coils can reach its maximum of 125 mT on the toroidal axis. The EC system is operated at 2.45 GHz with up to 6 kW forward power. The IC system can couple up to 6 kW in the frequency range of 10 MHz–50 MHz. The direct current glow discharge system is based on a graphite anode with a maximum voltage of 1.5 kV and a current of 6 A. A load-lock system with a vertical manipulator allows exposure of material samples. A number of diagnostics have been installed: single- and triple-pin Langmuir probes for radial plasma profiles, a time-of-flight neutral particle analyzer capable of detecting neutrals in the energy range of 10 eV–1000 eV, and a quadrupole mass spectrometer and video systems for plasma imaging. The majority of systems and diagnostics are controlled by the Siemens SIMATIC S7 system, which also provides safety interlocks.
- 1 February 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (2) , 023506
The upgraded TOMAS device: A toroidal plasma facility for wall conditioning, plasma production, and plasma–surface interaction studies
The Toroidal Magnetized System device has been significantly upgraded to enable development of various wall conditioning techniques, including methods based on ion and electron cyclotron (IC/EC) range of frequency plasmas, and to complement plasma–wall interaction research in tokamaks and stellarators. The toroidal magnetic field generated by 16 coils can reach its maximum of 125 mT on the toroidal axis. The EC system is operated at 2.45 GHz with up to 6 kW forward power. The IC system can couple up to 6 kW in the frequency range of 10 MHz–50 MHz. The direct current glow discharge system is based on a graphite anode with a maximum voltage of 1.5 kV and a current of 6 A. A load-lock system with a vertical manipulator allows exposure of material samples. A number of diagnostics have been installed: single- and triple-pin Langmuir probes for radial plasma profiles, a time-of-flight neutral particle analyzer capable of detecting neutrals in the energy range of 10 eV–1000 eV, and a quadrupole mass spectrometer and video systems for plasma imaging. The majority of systems and diagnostics are controlled by the Siemens SIMATIC S7 system, which also provides safety interlocks.