DADaniella Albuquerque

Daniella Albuquerque

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Daniella Albuquerque has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    MI-PACE Home-Based Cardiac Telerehabilitation Program for Heart Attack Survivors: Usability Study

    by Eric Y Ding, Nathaniel Erskine, Wim Stut, David D McManus, Amy Peterson, Ziyue Wang, Jorge Escobar Valle, Daniella Albuquerque, Alvaro Alonso, Naomi F Botkin, et al.

    Background: Cardiac rehabilitation programs, consisting of exercise training and disease management interventions, reduce morbidity and mortality after acute myocardial infarction. Objective: In this pilot study, we aimed to developed and assess the feasibility of delivering a health watch–informed 12-week cardiac telerehabilitation program to acute myocardial infarction survivors who declined to participate in center-based cardiac rehabilitation. Methods: We enrolled patients hospitalized after acute myocardial infarction at an academic medical center who were eligible for but declined to participate in center-based cardiac rehabilitation. Each participant underwent a baseline exercise stress test. Participants received a health watch, which monitored heart rate and physical activity, and a tablet computer with an app that displayed progress toward accomplishing weekly walking and exercise goals. Results were transmitted to a cardiac rehabilitation nurse via a secure connection. For 12 weeks, participants exercised at home and also participated in weekly phone counseling sessions with the nurse, who provided personalized cardiac rehabilitation solutions and standard cardiac rehabilitation education. We assessed usability of the system, adherence to weekly exercise and walking goals, counseling session attendance, and disease-specific quality of life. Results: Of 18 participants (age: mean 59 years, SD 7) who completed the 12-week telerehabilitation program, 6 (33%) were women, and 6 (33%) had ST-elevation myocardial infarction. Participants wore the health watch for a median of 12.7 hours (IQR 11.1, 13.8) per day and completed a median of 86% of exercise goals. Participants, on average, walked 121 minutes per week (SD 175) and spent 189 minutes per week (SD 210) in their target exercise heart rate zone. Overall, participants found the system to be highly usable (System Usability Scale score: median 83, IQR 65, 100). Conclusions: This pilot study established the feasibility of delivering cardiac telerehabilitation at home to acute myocardial infarction survivors via a health watch–based program and telephone counseling sessions. Usability and adherence to health watch use, exercise recommendations, and counseling sessions were high. Further studies are warranted to compare patient outcomes and health care resource utilization between center-based rehabilitation and telerehabilitation.


  • Open Access

    Development and Validation of an Automated Algorithm to Detect Atrial Fibrillation Within Stored Intensive Care Unit Continuous Electrocardiographic Data: Observational Study

    by Allan J Walkey, Syed K Bashar, Md Billal Hossain, Eric Ding, Daniella Albuquerque, Michael Winter, Ki H Chon, David D McManus

    Background: Atrial fibrillation (AF) is the most common arrhythmia during critical illness, representing a sepsis-defining cardiac dysfunction associated with adverse outcomes. Large burdens of premature beats and noisy signal during sepsis may pose unique challenges to automated AF detection. Objective: The objective of this study is to develop and validate an automated algorithm to accurately identify AF within electronic health care data among critically ill patients with sepsis. Methods: This is a retrospective cohort study of patients hospitalized with sepsis identified from Medical Information Mart for Intensive Care (MIMIC III) electronic health data with linked electrocardiographic (ECG) telemetry waveforms. Within 3 separate cohorts of 50 patients, we iteratively developed and validated an automated algorithm that identifies ECG signals, removes noise, and identifies irregular rhythm and premature beats in order to identify AF. We compared the automated algorithm to current methods of AF identification in large databases, including ICD-9 (International Classification of Diseases, 9th edition) codes and hourly nurse annotation of heart rhythm. Methods of AF identification were tested against gold-standard manual ECG review. Results: AF detection algorithms that did not differentiate AF from premature atrial and ventricular beats performed modestly, with 76% (95% CI 61%-87%) accuracy. Performance improved (P=.02) with the addition of premature beat detection (validation set accuracy: 94% [95% CI 83%-99%]). Median time between automated and manual detection of AF onset was 30 minutes (25th-75th percentile 0-208 minutes). The accuracy of ICD-9 codes (68%; P=.002 vs automated algorithm) and nurse charting (80%; P=.02 vs algorithm) was lower than that of the automated algorithm. Conclusions: An automated algorithm using telemetry ECG data can feasibly and accurately detect AF among critically ill patients with sepsis, and represents an improvement in AF detection within large databases.


  • Open Access

    Development and Validation of an Automated Algorithm to Detect Atrial Fibrillation Within Stored Intensive Care Unit Continuous Electrocardiographic Data: Observational Study (Preprint)

    by Allan J Walkey, Syed K Bashar, Billal Hossain, Eric Ding, Daniella Albuquerque, Michael Winter, Ki H Chon, David D McManus

    BACKGROUND Atrial fibrillation (AF) is the most common arrhythmia during critical illness, representing a sepsis-defining cardiac dysfunction associated with adverse outcomes. Large burdens of premature beats and noisy signal during sepsis may pose unique challenges to automated AF detection. OBJECTIVE The objective of this study is to develop and validate an automated algorithm to accurately identify AF within electronic health care data among critically ill patients with sepsis. METHODS This is a retrospective cohort study of patients hospitalized with sepsis identified from Medical Information Mart for Intensive Care (MIMIC III) electronic health data with linked electrocardiographic (ECG) telemetry waveforms. Within 3 separate cohorts of 50 patients, we iteratively developed and validated an automated algorithm that identifies ECG signals, removes noise, and identifies irregular rhythm and premature beats in order to identify AF. We compared the automated algorithm to current methods of AF identification in large databases, including ICD-9 (International Classification of Diseases, 9th edition) codes and hourly nurse annotation of heart rhythm. Methods of AF identification were tested against gold-standard manual ECG review. RESULTS AF detection algorithms that did not differentiate AF from premature atrial and ventricular beats performed modestly, with 76% (95% CI 61%-87%) accuracy. Performance improved (P=.02) with the addition of premature beat detection (validation set accuracy: 94% [95% CI 83%-99%]). Median time between automated and manual detection of AF onset was 30 minutes (25th-75th percentile 0-208 minutes). The accuracy of ICD-9 codes (68%; P=.002 vs automated algorithm) and nurse charting (80%; P=.02 vs algorithm) was lower than that of the automated algorithm. CONCLUSIONS An automated algorithm using telemetry ECG data can feasibly and accurately detect AF among critically ill patients with sepsis, and represents an improvement in AF detection within large databases.

  • Open Access

    MI-PACE Home-Based Cardiac Telerehabilitation Program for Heart Attack Survivors: Usability Study (Preprint)

    by Eric Y Ding, Nathaniel Erskine, Wim Stut, David D McManus, Amy Peterson, Ziyue Wang, Jorge Escobar Valle, Daniella Albuquerque, Alvaro Alonso, Naomi F Botkin, et al.

    BACKGROUND Cardiac rehabilitation programs, consisting of exercise training and disease management interventions, reduce morbidity and mortality after acute myocardial infarction. OBJECTIVE In this pilot study, we aimed to developed and assess the feasibility of delivering a health watch–informed 12-week cardiac telerehabilitation program to acute myocardial infarction survivors who declined to participate in center-based cardiac rehabilitation. METHODS We enrolled patients hospitalized after acute myocardial infarction at an academic medical center who were eligible for but declined to participate in center-based cardiac rehabilitation. Each participant underwent a baseline exercise stress test. Participants received a health watch, which monitored heart rate and physical activity, and a tablet computer with an app that displayed progress toward accomplishing weekly walking and exercise goals. Results were transmitted to a cardiac rehabilitation nurse via a secure connection. For 12 weeks, participants exercised at home and also participated in weekly phone counseling sessions with the nurse, who provided personalized cardiac rehabilitation solutions and standard cardiac rehabilitation education. We assessed usability of the system, adherence to weekly exercise and walking goals, counseling session attendance, and disease-specific quality of life. RESULTS Of 18 participants (age: mean 59 years, SD 7) who completed the 12-week telerehabilitation program, 6 (33%) were women, and 6 (33%) had ST-elevation myocardial infarction. Participants wore the health watch for a median of 12.7 hours (IQR 11.1, 13.8) per day and completed a median of 86% of exercise goals. Participants, on average, walked 121 minutes per week (SD 175) and spent 189 minutes per week (SD 210) in their target exercise heart rate zone. Overall, participants found the system to be highly usable (System Usability Scale score: median 83, IQR 65, 100). CONCLUSIONS This pilot study established the feasibility of delivering cardiac telerehabilitation at home to acute myocardial infarction survivors via a health watch–based program and telephone counseling sessions. Usability and adherence to health watch use, exercise recommendations, and counseling sessions were high. Further studies are warranted to compare patient outcomes and health care resource utilization between center-based rehabilitation and telerehabilitation.