Kshitiz Gupta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kshitiz Gupta has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
Avanish Mishra
3 shared publications- Steven T. Wereley
School of Mechanical Engineering, Purdue University, West Lafayette, USA
3 shared publications Zhengwei Chen
3 shared publications- Hector Garcia Martin
Joint BioEnergy Institute, Emeryville, CA, USA
2 shared publications Kaustav Gopinathan
2 shared publicationsSteven T. Wereley
2 shared publications
Latest Publications
- Open Access
- 28 November 2025
- Published by Elsevier in Current Opinion in Biotechnology
- Vol. 97, 103392
Perspectives for artificial intelligence in bioprocess automation
- 28 November 2025
- Published by Elsevier in Current Opinion in Biotechnology
- Vol. 97, 103392
Open AccessPerspectives for artificial intelligence in bioprocess automation
- Open Access
- 22 July 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (8) , 788
High-Throughput Microfluidic Electroporation (HTME): A Scalable, 384-Well Platform for Multiplexed Cell Engineering
Electroporation-mediated gene delivery is a cornerstone of synthetic biology, offering several advantages over other methods: higher efficiencies, broader applicability, and simpler sample preparation. Yet, electroporation protocols are often challenging to integrate into highly multiplexed workflows, owing to limitations in their scalability and tunability. These challenges ultimately increase the time and cost per transformation. As a result, rapidly screening genetic libraries, exploring combinatorial designs, or optimizing electroporation parameters requires extensive iterations, consuming large quantities of expensive custom-made DNA and cell lines or primary cells. To address these limitations, we have developed a High-Throughput Microfluidic Electroporation (HTME) platform that includes a 384-well electroporation plate (E-Plate) and control electronics capable of rapidly electroporating all wells in under a minute with individual control of each well. Fabricated using scalable and cost-effective printed-circuit-board (PCB) technology, the E-Plate significantly reduces consumable costs and reagent consumption by operating on nano to microliter volumes. Furthermore, individually addressable wells facilitate rapid exploration of large sets of experimental conditions to optimize electroporation for different cell types and plasmid concentrations/types. Use of the standard 384-well footprint makes the platform easily integrable into automated workflows, thereby enabling end-to-end automation. We demonstrate transformation of E. coli with pUC19 to validate the HTME’s core functionality, achieving at least a single colony forming unit in more than 99% of wells and confirming the platform’s ability to rapidly perform hundreds of electroporations with customizable conditions. This work highlights the HTME’s potential to significantly accelerate synthetic biology Design-Build-Test-Learn (DBTL) cycles by mitigating the transformation/transfection bottleneck.
- 22 July 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (8) , 788
Open AccessHigh-Throughput Microfluidic Electroporation (HTME): A Scalable, 384-Well Platform for Multiplexed Cell Engineering
Electroporation-mediated gene delivery is a cornerstone of synthetic biology, offering several advantages over other methods: higher efficiencies, broader applicability, and simpler sample preparation. Yet, electroporation protocols are often challenging to integrate into highly multiplexed workflows, owing to limitations in their scalability and tunability. These challenges ultimately increase the time and cost per transformation. As a result, rapidly screening genetic libraries, exploring combinatorial designs, or optimizing electroporation parameters requires extensive iterations, consuming large quantities of expensive custom-made DNA and cell lines or primary cells. To address these limitations, we have developed a High-Throughput Microfluidic Electroporation (HTME) platform that includes a 384-well electroporation plate (E-Plate) and control electronics capable of rapidly electroporating all wells in under a minute with individual control of each well. Fabricated using scalable and cost-effective printed-circuit-board (PCB) technology, the E-Plate significantly reduces consumable costs and reagent consumption by operating on nano to microliter volumes. Furthermore, individually addressable wells facilitate rapid exploration of large sets of experimental conditions to optimize electroporation for different cell types and plasmid concentrations/types. Use of the standard 384-well footprint makes the platform easily integrable into automated workflows, thereby enabling end-to-end automation. We demonstrate transformation of E. coli with pUC19 to validate the HTME’s core functionality, achieving at least a single colony forming unit in more than 99% of wells and confirming the platform’s ability to rapidly perform hundreds of electroporations with customizable conditions. This work highlights the HTME’s potential to significantly accelerate synthetic biology Design-Build-Test-Learn (DBTL) cycles by mitigating the transformation/transfection bottleneck.
- 29 March 2024
- Published by Elsevier
- p. 163-196
Droplet and digital microfluidics–enabled analytical techniques
- 29 March 2024
- Published by Elsevier
- p. 163-196
Droplet and digital microfluidics–enabled analytical techniques
- 29 March 2024
- Published by Elsevier
Contributors
- 4 July 2023
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 23 (15) , 3361-3369
A combinatorial droplet microfluidic device integrated with mass spectrometry for enzyme screening
We describe Drop-NIMS, a novel combination of droplet microfluidics and the matrix-free nanostructure-initiator mass spectrometry (NIMS) technology, with applications in enzyme screening.
- 4 July 2023
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 23 (15) , 3361-3369
A combinatorial droplet microfluidic device integrated with mass spectrometry for enzyme screening
We describe Drop-NIMS, a novel combination of droplet microfluidics and the matrix-free nanostructure-initiator mass spectrometry (NIMS) technology, with applications in enzyme screening.
- 18 August 2021
- Published by Wiley in Electrophoresis
- Vol. 42 (23) , 2483-2489
Time‐resolved particle image velocimetry analysis and computational modeling of transient optically induced electrothermal micro vortex
Trapping, sorting, transportation, and manipulation of synthetic microparticles and biological cells enable investigations in their behavior and properties. Microfluidic techniques like rapid electrokinetic patterning (REP) provide a non‐invasive means to probe into the nature of these micro and nanoparticles. The opto‐electrically induced nature of a REP micro vortex allows tuning of the trap characteristics in real‐time. In this work, we studied the effects of transient optical heating on the induced electrothermal vortex using micro‐particle image velocimetry (μ‐PIV) and computational modeling. A near infra‐red (980 nm) laser beam was focused on a colloidal suspension of 1 μm polystyrene beads sandwiched between two parallel‐plate electrodes. The electrodes were subjected to an AC current. The laser spot was scanned back‐and‐forth in a line, at different frequencies, to create the transient vortex. This phenomenon was also studied with a computational model made using COMSOL Multiphysics. We visualize fluid flow in custom‐shaped REP traps by superposing multiple axisymmetric (spot) vortices and discuss the limitations of using superposition in dynamically changing traps.
- 18 August 2021
- Published by Wiley in Electrophoresis
- Vol. 42 (23) , 2483-2489
Time‐resolved particle image velocimetry analysis and computational modeling of transient optically induced electrothermal micro vortex
Trapping, sorting, transportation, and manipulation of synthetic microparticles and biological cells enable investigations in their behavior and properties. Microfluidic techniques like rapid electrokinetic patterning (REP) provide a non‐invasive means to probe into the nature of these micro and nanoparticles. The opto‐electrically induced nature of a REP micro vortex allows tuning of the trap characteristics in real‐time. In this work, we studied the effects of transient optical heating on the induced electrothermal vortex using micro‐particle image velocimetry (μ‐PIV) and computational modeling. A near infra‐red (980 nm) laser beam was focused on a colloidal suspension of 1 μm polystyrene beads sandwiched between two parallel‐plate electrodes. The electrodes were subjected to an AC current. The laser spot was scanned back‐and‐forth in a line, at different frequencies, to create the transient vortex. This phenomenon was also studied with a computational model made using COMSOL Multiphysics. We visualize fluid flow in custom‐shaped REP traps by superposing multiple axisymmetric (spot) vortices and discuss the limitations of using superposition in dynamically changing traps.
- 17 February 2021
- Published by American Physical Society (APS) in Physical Review Fluids
- Vol. 6 (2) , 023701
Nature of trapping forces in optically induced electrothermal vortex based tweezers
Rapid electrokinetic patterning (REP) is an emerging microfluidic tweezer which can dynamically trap and manipulate micro- and nanoparticles via modulation of electrothermal vortices with optical patterns. By analyzing the trajectory of trapped particles with subpixel resolution, we show that the transverse trapping force in REP originates due to axisymmetric Stokes drag experienced by the particles in toroidal electrothermal vortices. The trapping force scales linearly with radial distance from the trap center and trap stiffness is on the order of femtonewtons/μm in the transverse plane. This low trap stiffness is a direct feature of the fluidic nature of the REP trapping and would be useful for measuring femtonewton-scale forces.
- 17 February 2021
- Published by American Physical Society (APS) in Physical Review Fluids
- Vol. 6 (2) , 023701
Nature of trapping forces in optically induced electrothermal vortex based tweezers
Rapid electrokinetic patterning (REP) is an emerging microfluidic tweezer which can dynamically trap and manipulate micro- and nanoparticles via modulation of electrothermal vortices with optical patterns. By analyzing the trajectory of trapped particles with subpixel resolution, we show that the transverse trapping force in REP originates due to axisymmetric Stokes drag experienced by the particles in toroidal electrothermal vortices. The trapping force scales linearly with radial distance from the trap center and trap stiffness is on the order of femtonewtons/μm in the transverse plane. This low trap stiffness is a direct feature of the fluidic nature of the REP trapping and would be useful for measuring femtonewton-scale forces.