Sagie Haziza
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sagie Haziza has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
Victor H. Hernandez
University of Miami Hospital, Department of Orthopaedics, Miami, FL, USA
7 shared publicationsRamakanth R. Yakkanti
University of Miami Hospital, Department of Orthopaedics, Miami, FL, USA
3 shared publications- Alexis Driscoll
Department of Orthopaedic Surgery Tufts Medical Center Boston Massachusetts U.S.A.
1 shared publication Angelo Mannino
Department of Orthopaedic Surgery, Maimonides Medical Center, Brooklyn, New York
1 shared publicationBradley A Lezak
University of Miami Miller School of Medicine, Miami, FL, USA
1 shared publicationBradley A. Lezak
University of Miami Miller School of Medicine, Miami, FL, USA
1 shared publication
Latest Publications
- Open Access
- 1 January 2026
- Published by Wiley in Case Reports in Orthopedics
- Vol. 2026 (1)
Simultaneous Bilateral Tibial Tubercle Avulsion Fractures Complicated by Compartment Syndrome in an Adolescent With Osteogenesis Imperfecta: A Case Report
Background: Osteogenesis imperfecta (OI) is a rare collagen disorder causing brittle bones. Tibial tubercle fractures are uncommon in children, comprising < 2.7% of pediatric fractures, and bilateral injuries in OI are exceptionally rare. No prior reports detail bilateral tibial tubercle fractures with concurrent bilateral compartment syndrome. We present the first known case of this presentation in an 11‐year‐old boy. Case Presentation: An 11‐year‐old male with OI fell on his knees, presenting with severe bilateral leg pain. Imaging revealed bilateral Ogden III tibial tubercle fractures. Due to tense compartments, emergent fasciotomies were performed, followed by open reduction and internal fixation. At 16‐month follow‐up, the patient reported no complications and demonstrated normal ambulation. Conclusion: Surgeons should maintain a high index of suspicion for compartment syndrome in patients with OI presenting with tibial tubercle fractures, including after low‐energy mechanisms, and intervene promptly when clinically indicated.
- 1 January 2026
- Published by Wiley in Case Reports in Orthopedics
- Vol. 2026 (1)
Open AccessSimultaneous Bilateral Tibial Tubercle Avulsion Fractures Complicated by Compartment Syndrome in an Adolescent With Osteogenesis Imperfecta: A Case Report
Background: Osteogenesis imperfecta (OI) is a rare collagen disorder causing brittle bones. Tibial tubercle fractures are uncommon in children, comprising < 2.7% of pediatric fractures, and bilateral injuries in OI are exceptionally rare. No prior reports detail bilateral tibial tubercle fractures with concurrent bilateral compartment syndrome. We present the first known case of this presentation in an 11‐year‐old boy. Case Presentation: An 11‐year‐old male with OI fell on his knees, presenting with severe bilateral leg pain. Imaging revealed bilateral Ogden III tibial tubercle fractures. Due to tense compartments, emergent fasciotomies were performed, followed by open reduction and internal fixation. At 16‐month follow‐up, the patient reported no complications and demonstrated normal ambulation. Conclusion: Surgeons should maintain a high index of suspicion for compartment syndrome in patients with OI presenting with tibial tubercle fractures, including after low‐energy mechanisms, and intervene promptly when clinically indicated.
- Open Access
- 16 February 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (4) , 1123
Dynamic Locking Plate versus Multiple Cancellous Screws for the Fixation of Intracapsular Femoral Neck Fractures: Long-Term Results and Quality-Of-Life Assessment Based on Patient-Reported Outcome Measures
The purpose of this study was to compare the long-term clinical outcomes and quality-of-life measures for two fixation methods in the setting of displaced femoral neck fractures. The two groups included fixation with multiple cancellous screws (group 1) and telescopic femoral neck screws and a small locking plate device (Targon FN) (group 2). Patients underwent reduction and internal fixation with either multiple cancellous screws or the Targon FN device from March 2000 to January 2012. Failure endpoints included nonunion, osteonecrosis of the femoral head, and revision surgery. Patient-reported outcome measures included chronic pain, ability to ambulate, and the use of ambulation assistive devices. Statistical analysis demonstrated a statistically significant lower rate of non-union and overall complication in the Targon FN group (p value < 0.001 and p value = 0.005, respectively). Logistic regression analysis showed that operative fixation with the Targon FN device decreased the odds ratio for overall complication by a factor of 0.34 (p = 0.02). There were no statistically significant differences between groups 1 and 2 in patient-reported outcomes (chronic pain (p = 0.21), ability to ambulate (p = 0.07), and the use of an ambulation assistive device (p = 0.07)). When compared to traditional cancellous screw fixation of femoral neck fractures, the Targon FN device has significantly lower complication rates and equivalent patient-reported outcomes.
- 16 February 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (4) , 1123
Open AccessDynamic Locking Plate versus Multiple Cancellous Screws for the Fixation of Intracapsular Femoral Neck Fractures: Long-Term Results and Quality-Of-Life Assessment Based on Patient-Reported Outcome Measures
The purpose of this study was to compare the long-term clinical outcomes and quality-of-life measures for two fixation methods in the setting of displaced femoral neck fractures. The two groups included fixation with multiple cancellous screws (group 1) and telescopic femoral neck screws and a small locking plate device (Targon FN) (group 2). Patients underwent reduction and internal fixation with either multiple cancellous screws or the Targon FN device from March 2000 to January 2012. Failure endpoints included nonunion, osteonecrosis of the femoral head, and revision surgery. Patient-reported outcome measures included chronic pain, ability to ambulate, and the use of ambulation assistive devices. Statistical analysis demonstrated a statistically significant lower rate of non-union and overall complication in the Targon FN group (p value < 0.001 and p value = 0.005, respectively). Logistic regression analysis showed that operative fixation with the Targon FN device decreased the odds ratio for overall complication by a factor of 0.34 (p = 0.02). There were no statistically significant differences between groups 1 and 2 in patient-reported outcomes (chronic pain (p = 0.21), ability to ambulate (p = 0.07), and the use of an ambulation assistive device (p = 0.07)). When compared to traditional cancellous screw fixation of femoral neck fractures, the Targon FN device has significantly lower complication rates and equivalent patient-reported outcomes.
- Open Access
- 17 January 2024
- Published by MDPI AG in Preprints.org
Dynamic Locking Plate versus Multiple Cancellous Screws for the Fixation of Intracapsular Femoral Neck Fractures: Long-Term Results and Prom Based Quality of Life Assessment
The purpose of this study was to compare the long-term clinical outcomes and quality of life measures for two fixation methods in the setting of displaced femoral neck fractures. The two groups included fixation with multiple cancellous screws (group 1) and telescopic femoral neck screws and small locking plate device (Targon FN) (group 2). Patients underwent reduction and internal fixation with either multiple cancellous screws or Targon FN device from March 2000 to January 2012. Failure endpoints included nonunion, osteonecrosis of the femoral head, and revision surgery. Patient reported outcome measures included chronic pain, ability to ambulate, and the use of ambulation assistive devices. Statistical analysis demonstrated a statistically significant lower rate of non-union and overall complication in the Targon FN group (p value < 0.001 and p value = 0.005 respectively). Logistic regression analysis showed that operative fixation with the Targon FN device decreased the odds ratio for overall complication by a factor of 0.34 (P = 0.02). There were no statistically significant differences between groups 1 and 2 in patient reported outcomes (chronic pain (p-0.21), ability to ambulate (p- 0.07), and the use of ambulation assistive device (p-0.07)). When compared to traditional cancellous screw fixation of femoral neck fractures, the Targon FN device has significantly lower complications rates and equivalent patient reported outcomes.
- 17 January 2024
- Published by MDPI AG in Preprints.org
Open AccessDynamic Locking Plate versus Multiple Cancellous Screws for the Fixation of Intracapsular Femoral Neck Fractures: Long-Term Results and Prom Based Quality of Life Assessment
The purpose of this study was to compare the long-term clinical outcomes and quality of life measures for two fixation methods in the setting of displaced femoral neck fractures. The two groups included fixation with multiple cancellous screws (group 1) and telescopic femoral neck screws and small locking plate device (Targon FN) (group 2). Patients underwent reduction and internal fixation with either multiple cancellous screws or Targon FN device from March 2000 to January 2012. Failure endpoints included nonunion, osteonecrosis of the femoral head, and revision surgery. Patient reported outcome measures included chronic pain, ability to ambulate, and the use of ambulation assistive devices. Statistical analysis demonstrated a statistically significant lower rate of non-union and overall complication in the Targon FN group (p value < 0.001 and p value = 0.005 respectively). Logistic regression analysis showed that operative fixation with the Targon FN device decreased the odds ratio for overall complication by a factor of 0.34 (P = 0.02). There were no statistically significant differences between groups 1 and 2 in patient reported outcomes (chronic pain (p-0.21), ability to ambulate (p- 0.07), and the use of ambulation assistive device (p-0.07)). When compared to traditional cancellous screw fixation of femoral neck fractures, the Targon FN device has significantly lower complications rates and equivalent patient reported outcomes.
- 27 September 2022
- Published by Elsevier in Journal of Orthopaedics
- Vol. 34, 322-326
Relative frequency of primary total hip arthroplasty for avascular necrosis in the United States as compared to a regional center: A data review
- 27 September 2022
- Published by Elsevier in Journal of Orthopaedics
- Vol. 34, 322-326
Relative frequency of primary total hip arthroplasty for avascular necrosis in the United States as compared to a regional center: A data review
- 1 April 2022
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 37 (8) , 1606-1611
Survivorship and Outcomes of Femoral Neck Preserving Stems in Primary Total Hip Arthroplasty
- 1 April 2022
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 37 (8) , 1606-1611
Survivorship and Outcomes of Femoral Neck Preserving Stems in Primary Total Hip Arthroplasty
- 19 January 2022
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 37 (5) , 809-813
Time-Driven Activity-Based Costing in Preoperative Tasks for Total Hip and Knee Arthroplasty
- 19 January 2022
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 37 (5) , 809-813
Time-Driven Activity-Based Costing in Preoperative Tasks for Total Hip and Knee Arthroplasty
- 1 January 2022
- Published by Indian Orthopaedic Research Group in Journal of Orthopaedic Case Reports
- Vol. 12 (5) , 105-108
A Tale of Two Suprascapular Neuropathy Presentations: A Case Report
Introduction: Supra-scapular nerve (SSN) neuropathy is a rare condition that can cause shoulder dysfunction. Prior literature has identified mass effect, space occupying lesions, trauma, and repetitive overhead activities as possible etiologies. Cases Presentations: We report two cases of SSN neuropathy; a 21-year-old competitive female volleyball player with traction associated neuropathy and a 45-year-old male with a large paralabral ganglion cyst causing compressive neuropathy. Conclusion: The following report highlights two different etiologies of SSN neuropathy and reviews the treatment of these conditions. Clinicians should consider SSN neuropathy in patients with unexplained shoulder pain and dysfunction.
- 1 January 2022
- Published by Indian Orthopaedic Research Group in Journal of Orthopaedic Case Reports
- Vol. 12 (5) , 105-108
A Tale of Two Suprascapular Neuropathy Presentations: A Case Report
Introduction: Supra-scapular nerve (SSN) neuropathy is a rare condition that can cause shoulder dysfunction. Prior literature has identified mass effect, space occupying lesions, trauma, and repetitive overhead activities as possible etiologies. Cases Presentations: We report two cases of SSN neuropathy; a 21-year-old competitive female volleyball player with traction associated neuropathy and a 45-year-old male with a large paralabral ganglion cyst causing compressive neuropathy. Conclusion: The following report highlights two different etiologies of SSN neuropathy and reviews the treatment of these conditions. Clinicians should consider SSN neuropathy in patients with unexplained shoulder pain and dysfunction.
- 2 December 2021
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 143 (3) , 1311-1321
Perioperative management of acetabular and pelvic fractures: evidence-based recommendations
Purpose The American Academy of Orthopaedic Surgeons does not currently provide clinical practice guidelines for management of PAF. Accordingly, this article aims to review and consolidate the relevant historical and recent literature in important topics pertaining to perioperative management of PAF. Methods A thorough literature review using PubMed, Cochrane and Embase databases was performed to assess preoperative, intraoperative and postoperative management of PAF fracture. Topics reviewed included: time from injury to definitive fixation, the role of inferior vena cava filters (IVCF), tranexamic acid (TXA) use, intraopoperative cell salvage, incisional negative pressure wound therapy (NPWT), intraoperative antibiotic powder use, heterotopic ossification prophylaxis, and pre- and postoperative venous thromboembolism (VTE) prophylaxis. Results A total of 126 articles pertaining to the preoperative, intraoperative and postoperative management of PAF were reviewed. Articles reviewed by topic include 13 articles pertaining to time to fixation, 23 on IVCF use, 14 on VTE prophylaxis, 20 on TXA use, 10 on cell salvage, 10 on iNPWT 14 on intraoperative antibiotic powder and 20 on HO prophylaxis. An additional eight articles were reviewed to describe background information. Five articles provided information for two or more treatment modalities and were therefore included in multiple categories when tabulating the number of articles reviewed per topic. Conclusion The literature supports the use of radiation therapy for HO prophylaxis, early (< 5 days from injury) surgical intervention and the routine use of intraoperative TXA. The literature does not support the routine use of iNPWT or IVCF. There is inadequate information to make a recommendation regarding the use of cell salvage and wound infiltration with antibiotic powder. While the routine use of chemical VTE prophylaxis is recommended, there is insufficient evidence to recommend the optimal agent and duration of therapy.
- 2 December 2021
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 143 (3) , 1311-1321
Perioperative management of acetabular and pelvic fractures: evidence-based recommendations
Purpose The American Academy of Orthopaedic Surgeons does not currently provide clinical practice guidelines for management of PAF. Accordingly, this article aims to review and consolidate the relevant historical and recent literature in important topics pertaining to perioperative management of PAF. Methods A thorough literature review using PubMed, Cochrane and Embase databases was performed to assess preoperative, intraoperative and postoperative management of PAF fracture. Topics reviewed included: time from injury to definitive fixation, the role of inferior vena cava filters (IVCF), tranexamic acid (TXA) use, intraopoperative cell salvage, incisional negative pressure wound therapy (NPWT), intraoperative antibiotic powder use, heterotopic ossification prophylaxis, and pre- and postoperative venous thromboembolism (VTE) prophylaxis. Results A total of 126 articles pertaining to the preoperative, intraoperative and postoperative management of PAF were reviewed. Articles reviewed by topic include 13 articles pertaining to time to fixation, 23 on IVCF use, 14 on VTE prophylaxis, 20 on TXA use, 10 on cell salvage, 10 on iNPWT 14 on intraoperative antibiotic powder and 20 on HO prophylaxis. An additional eight articles were reviewed to describe background information. Five articles provided information for two or more treatment modalities and were therefore included in multiple categories when tabulating the number of articles reviewed per topic. Conclusion The literature supports the use of radiation therapy for HO prophylaxis, early (< 5 days from injury) surgical intervention and the routine use of intraoperative TXA. The literature does not support the routine use of iNPWT or IVCF. There is inadequate information to make a recommendation regarding the use of cell salvage and wound infiltration with antibiotic powder. While the routine use of chemical VTE prophylaxis is recommended, there is insufficient evidence to recommend the optimal agent and duration of therapy.
- 31 August 2021
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 36 (03) , 322-328
Effects of Venous Insufficiency in Patients Undergoing Primary Total Knee Arthroplasty: An Analysis of 1.2 Million Patients
Chronic venous insufficiency (CVI) is extraordinarily prevalent in our aging population with over 30 million people in the United States suffering from the disease. There is a paucity of data analyzing the effects of CVI on outcomes following total knee arthroplasty (TKA). The purpose of this study was to utilize a nationwide administrative claims database to determine whether patients with CVI undergoing TKA have higher rates of: (1) in-hospital lengths of stay (LOS); (2) readmission rates; (3) medical complications; (4) implant-related complications; and (5) costs of care compared to controls. Using a nationwide database, we matched patients with CVI undergoing TKA to controls without CVI undergoing TKA in a 1:5 ratio by age, sex, and medical comorbidities associated with CVI. Primary outcomes analyzed within the study included LOS, 90-day readmission rates, 90-day medical complications, 2-year implant-related complications, in addition to 90-day total global episode of care costs. The query yielded 1,265,534 patients with (n = 210,926) and without (n = 1,054,608) CVI undergoing primary TKA. Patients with CVI had significantly longer LOS (4 vs. 3 days, p < 0.0001), higher 90-day readmission rates (20.96 vs. 15.34%; odds ratio [OR]: 1.46, 95% confidence interval [CI]: 1.44–1.48, p < 0.0001), and higher odds of medical complications (2.27 vs. 1.30%; OR: 1.76, 95% CI: 1.70–1.83, p < 0.0001) compared to matched controls. Patients with CVI also had higher odds of periprosthetic joint infections (2.23 vs. 1.03%; OR: 2.18, p < 0.0001) and implant-related complications in general (4.27 vs. 2.17%; OR: 2.01, 95% CI: 1.96–2.06, p < 0.0001). Additionally, patients with CVI had higher total global 90-day episode of care costs ($15,583.07 vs. $14,286.95, p < 0.0001). Patients with CVI undergoing TKA have increased LOS, higher odds of medical and implant complications, and increased costs of care compared to those without CVI. The study can be utilized by orthopaedic surgeons to counsel patients on the potential complications following this procedure. This is a level III, retrospective cohort study.
- 31 August 2021
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 36 (03) , 322-328
Effects of Venous Insufficiency in Patients Undergoing Primary Total Knee Arthroplasty: An Analysis of 1.2 Million Patients
Chronic venous insufficiency (CVI) is extraordinarily prevalent in our aging population with over 30 million people in the United States suffering from the disease. There is a paucity of data analyzing the effects of CVI on outcomes following total knee arthroplasty (TKA). The purpose of this study was to utilize a nationwide administrative claims database to determine whether patients with CVI undergoing TKA have higher rates of: (1) in-hospital lengths of stay (LOS); (2) readmission rates; (3) medical complications; (4) implant-related complications; and (5) costs of care compared to controls. Using a nationwide database, we matched patients with CVI undergoing TKA to controls without CVI undergoing TKA in a 1:5 ratio by age, sex, and medical comorbidities associated with CVI. Primary outcomes analyzed within the study included LOS, 90-day readmission rates, 90-day medical complications, 2-year implant-related complications, in addition to 90-day total global episode of care costs. The query yielded 1,265,534 patients with (n = 210,926) and without (n = 1,054,608) CVI undergoing primary TKA. Patients with CVI had significantly longer LOS (4 vs. 3 days, p < 0.0001), higher 90-day readmission rates (20.96 vs. 15.34%; odds ratio [OR]: 1.46, 95% confidence interval [CI]: 1.44–1.48, p < 0.0001), and higher odds of medical complications (2.27 vs. 1.30%; OR: 1.76, 95% CI: 1.70–1.83, p < 0.0001) compared to matched controls. Patients with CVI also had higher odds of periprosthetic joint infections (2.23 vs. 1.03%; OR: 2.18, p < 0.0001) and implant-related complications in general (4.27 vs. 2.17%; OR: 2.01, 95% CI: 1.96–2.06, p < 0.0001). Additionally, patients with CVI had higher total global 90-day episode of care costs ($15,583.07 vs. $14,286.95, p < 0.0001). Patients with CVI undergoing TKA have increased LOS, higher odds of medical and implant complications, and increased costs of care compared to those without CVI. The study can be utilized by orthopaedic surgeons to counsel patients on the potential complications following this procedure. This is a level III, retrospective cohort study.