SWShizhen Steven Wang

Shizhen Steven Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Shizhen Steven Wang has a total of 55 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Enumeration Comparison Study of BACARA® 2 and RAPID’B. cereus® Agars to Mannitol-Egg Yolk-Polymyxin (MYP) Agar for Detection of Bacillus cereus Group Strains

    by Guojie Cao, Jennifer Miller, Shizhen Steven Wang, Sandra Tallent

    Background: The Bacillus cereus group (B. cereus sensu lato) is a group of spore-forming strains. B. cereus group is a human pathogen associated with foodborne outbreaks with symptoms of diarrhea and emesis. Objective: This study evaluates the performance of BACARA® 2 (BAC2) and RAPID’B. cereus® (RAPID) agars compared to mannitol–egg yolk–polymyxin (MYP) agars and the original BACARA® (BAC) media to detect and enumerate the B. cereus group in pure culture and foods. Methods: We incorporated five food types to include liquid milk, whey powder, mashed potatoes, rice, and tea bags. For each food matrix, there were five test portions per level inoculum prepared (low, medium, and high), and a negative control. Individual test portions were diluted 1:10 in Butterfield’s phosphate buffer (BPB) and 0.1 mL of the dilutions were inoculated on BAC2, RAPID, and MYP agars. In-house R script was applied to conduct statistical analysis to compare medium performance in food adulteration tests. Results: Inclusivity testing determined that all six B. cytotoxicus strains grew on BAC2, RAPID, and MYP but only one strain grew on BAC after 24 h incubation. RAPID had similar results as BAC2 in single-colony tests. In food tests, relative level of detection (RLOD) values indicated MYP was more sensitive for detecting B. cereus strains than BAC2 and RAPID, which is a result of B. cytotoxicus strains in mashed potato and whey powder needing an additional 24-hour incubation to exhibit typical morphology on BAC2 and RAPID. Conclusion: Our study demonstrated the use of BAC2 and/or RAPID agar will improve the performance of the U.S. Food and Drug Administration Bacteriological Analytical Manual (BAM) B. cereus method, particularly for the detection of B. cytotoxicus. Importantly, the use of BAC2 and/or RAPID will decrease the time to detect viable B. cereus strains without additional confirmation steps compared to MYP. Highlights: For improved isolation and identification of B. cereus group in foods, we propose the use of BAC2 or RAPID as optional agars, along with MYP.


  • Open Access

    Sample Size Determination for Food Sampling

    by Shizhen S. Wang, Travis A. Canida, John D. Ihrie, Stuart J. Chirtel


  • Sampling plan designs for gluten estimation in oat flour by discrete and composite sampling

    by Girdhari M. Sharma, Shizhen S. Wang, Marion Pereira, Binaifer Bedford, Paul Wehling, Mark Arlinghaus, Josh Warren, Thomas B. Whitaker, Lauren S. Jackson, Travis Canida, et al.


  • Open Access

    On the Estimation of POD and LOD of Qualitative Microbiological Assays from a Multi-Laboratory Validation Study

    by Shizhen S Wang, John Ihrie

    Jarvis et al. (J. AOAC Int. 102: 1617-1623) estimated the mean laboratory effect (µ), standard deviation of laboratory effects (σ), probability of detection (POD), and level of detection (LOD) from a multi-laboratory validation study of qualitative microbiological assays using a random intercept complementary log-log model. Their approach estimated σ based on a Laplace approximation to the likelihood function of the model but estimated µ from a fixed effect model. We compared the estimates of µ and σ from three approaches (the Laplace approximation that estimates µ and σ simultaneously from the random intercept model, adaptive Gauss-Hermite quadrature (AGHQ), and the method of Jarvis et al.) and introduced a R Shiny app to implement the AGHQ using the widely used “lme4” R package. We conducted a simulation study to compare accuracy of the estimates of µ and σ from the three approaches and compared the estimates of µ, σ, LOD, etc. between the R Shiny app and the spreadsheet calculation tool developed by Jarvis et al. for an example dataset. Our simulation study shows that, while the three approaches produce a similar estimate of σ, the AGHQ has generally the best performance for estimating µ (and hence mean POD and LOD). The differences in the estimates between the R Shiny app and the spreadsheet were demonstrated using the example dataset. The AGHQ is the best method for estimating µ, POD, and LOD. The user-friendly R Shiny app provides a better alternative to the spreadsheet.


  • Open Access

    On the Statistical Testing Methods for Single Laboratory Validation of Qualitative Microbiological Assays with an Unpaired Design

    by Shizhen S Wang

    Background: There exists several statistical methods for detecting a difference of detection rates between alternative and reference qualitative microbiological assays in a single laboratory validation study with an unpaired design. Objective: We compared performance of eight methods including Fisher's exact test, unequal variance two-sample t-test, Wilcoxon rank-sumtest, z-test, and methods based on Wilson confidence intervals, complementary log-log regression, Firth's logistic regression, and ordinary logistic regression. Method: We first compared the minimum detectable difference in the proportion of detections between the alternative and reference methods among these statistical methods for a varied number of test portions. We then compared power and size of test of these methods using simulated data. Results: Firth's logistic regression and the unequal variance two-sample t-test had the lowest minimum detectable difference and highest power. None of these statistical methods had an estimated size of test always within a 95% confidence interval of the nominal value 0.05 with small numbers of test portions (n = 12, 20, 30). Fisher's exact test, the Wilcoxon rank-sumtest, and the z-test were conservative even with a moderately large number of test portions (n = 40), while Firth's logistic regression and the unequal variance two-sample t-test had a size of test closer to 0.05 than other methods. Conclusions: Firth's logistic regression and the unequal variance two-sample t-test are better choices than other competing methods. Highlights: We recommend the unequal variance two-sample t-test over Firth's logistic regression because the unequal variance two-sample t-test is better known and easier to use. We provide an example using real data.


  • Open Access

    On the Statistical Testing Methods for Single Laboratory Validation of Qualitative Microbiological Assays with a Paired Design

    by Shizhen S Wang

    There are several statistical methods for detecting a difference of detection rates between alternative and reference qualitative microbiological assays in a single laboratory validation study with a paired design. We compared performance of eight methods including McNemar’s test, sign test, Wilcoxon signed-rank test, paired t-test, and the regression methods based on conditional logistic (CLOGIT), mixed effects complementary log-log (MCLOGLOG), mixed effects logistic (MLOGIT) models and a linear mixed effects model (LMM). We first compared the minimum detectable difference in the proportion of detections between the alternative and reference detection methods among these statistical methods for a varied number of test portions. We then compared power and type 1 error rates of these methods using simulated data. The MCLOGLOG and MLOGIT models had the lowest minimum detectable difference, followed by the LMM and paired t-test. The MCLOGLOG and MLOGIT models had the highest average power but were anticonservative when correlation between the pairs of outcome values of the alternative and reference methods was high. The LMM and paired t-test had mostly the highest average power when the correlation was low and the second highest average power when the correlation was high. Type 1 error rates of these last two methods approached the nominal value of significance level when the number of test portions was moderately large (n > 20). The LMM and paired t-test are better choices than other competing methods, and we provide an example using real data.


  • Open Access

    Multi-Laboratory Validation of a Loop-Mediated Isothermal Amplification Method for Screening Salmonella in Animal Food

    by Beilei Ge, Kelly J. Domesle, Qianru Yang, Thomas S. Hammack, Shizhen S. Wang, Xiaohong Deng, Lijun Hu, Guodong Zhang, Yuan Hu, Xiaokuang Lai, et al.

    Loop-mediated isothermal amplification (LAMP) has gained wide popularity in the detection of Salmonella in foods owing to its simplicity, rapidity, and robustness. This multi-laboratory validation (MLV) study aimed to validate a Salmonella LAMP-based method against the United States Food and Drug Administration (FDA) Bacteriological Analytical Manual (BAM) Chapter 5 Salmonella reference method in a representative animal food matrix (dry dog food). Fourteen independent collaborators from seven laboratories in the United States and Canada participated in the study. Each collaborator received two sets of 24 blind-coded dry dog food samples (eight uninoculated; eight inoculated at a low level, 0.65 MPN/25 g; and eight inoculated at a high level, 3.01 MPN/25 g) and initiated the testing on the same day. The MLV study used an unpaired design where different test portions were analyzed by the LAMP and BAM methods using different preenrichment protocols (buffered peptone water for LAMP and lactose broth for BAM). All LAMP samples were confirmed by culture using the BAM method. BAM samples were also tested by LAMP following lactose broth preenrichment (paired samples). Statistical analysis was carried out by the probability of detection (POD) per AOAC guidelines and by a random intercept logistic regression model. Overall, no significant differences in POD between the Salmonella LAMP and BAM methods were observed with either unpaired or paired samples, indicating the methods were comparable. LAMP testing following preenrichment in buffered peptone water or lactose broth also resulted in insignificant POD differences (P > 0.05). The MLV study strongly supports the utility and applicability of this rapid and reliable LAMP method in routine regulatory screening of Salmonella in animal food.


  • A common polymorphism is associated with body mass index in Uyghur population

    by Jun Zhang, Rong Lin, Fen Wang, Ming Lu, Ren-Yong Lin, Shi-Zhen Wang, Hao Wen, Li Jin, Xiao-Feng Wang