YLYan Li

Yan Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yan Li has a total of 77 co-authors. Here are the top co-authors by number of shared publications:

  • Haoyun Wei

    State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing 100084, China

    30 shared publications
  • Haoyun Wei

    State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing 100084, China

    12 shared publications
  • Jiarui Li

    State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing 100084, China

    8 shared publications
  • Kun Chen

    Key Laboratory of Precision Measurement Technology & Instrument, Department of Precision Instrument, Tsinghua University, Beijing 100084, China

    6 shared publications
  • Hongyuan Zhang

    Cole Eye Institute Cleveland Clinic 44195 Cleveland USA

    5 shared publications
  • Taoran Le

    Tsinghua Univ, Dept Precis Instruments, State Key Lab Precis Measurement Technol & Instrum, Beijing 100084, Peoples R China

    5 shared publications

Latest Publications

  • Open Access

    Temperature-Invariant High-Resolution Imaging for Automotive Cameras Using Collaborative Passive Compensation

    by Kouwen Zhang, Zhaoqing Liu, Xiaoyang Lin, Shenwei Xu, Junyu Zhou, Yan Li, Haoyun Wei

    Thermal-induced degradation of modulation transfer function (MTF) and image sharpness in automotive camera modules under large real-world temperature variations is a key bottleneck for the safe deployment of level 3 and higher advanced driver assistance systems. To address this challenge, a collaborative passive compensation framework is proposed to maintain high-resolution imaging performance across extreme temperature conditions. Within this framework, an elastic spacer is embedded into the lens stack as an additional optical design degree of freedom. This carefully engineered element expands the thermal focus compensation capability of the lens assembly and suppresses inherent back focal plane (BFP) drift within a narrow range through coordinated opto-mechanical coupling optimal design. Then, a metal stiffener plate is introduced to tailor the thermo-mechanical deformation behavior of the detector-mounted printed circuit board. By optimizing the thickness of the stiffener plate, the residual thermally induced BFP drift of the overall opto-mechanical system is effectively counteracted, enabling global opto-mechanical–thermal equilibrium. Experimental results from the prototype camera module demonstrate that, over an ultra-wide temperature range from −40 °C to +95 °C, the maximum absolute BFP mismatch between the lens optical focus plane and the image sensor plane is constrained within 1m, achieving ∼90% reduction compared with conventional optical-only athermalization approaches. At a spatial frequency of 119 lp/mm, the MTF at the center and the left/right 0.7-field positions consistently exceeds the design threshold of 0.5 with negligible degradation throughout the full temperature range. These results demonstrate that the proposed approach enables a fully passive, temperature-invariant automotive camera module, achieving an optimal balance among compactness, cost efficiency, and robustness under harsh automotive operating conditions.

  • Open Access

    Optical–Structural Optimization for Condensation Suppression in Automotive Camera Modules

    by Kouwen Zhang, Yike Xu, Shenwei Xu, Xiaoyang Lin, Junyu Zhou, Zhaoqing Liu, Yan Li, Haoyun Wei

    Cameras have become indispensable sensors in intelligent vehicles, with their deployment steadily increasing across modern automobiles. It is critical for camera modules to have reliable and accurate environmental perception, but a major challenge is condensation inside the modules that severely compromises imaging quality. To address this issue, we performed comprehensive thermodynamics-based simulations to clarify condensation mechanisms and evaluate their impact on optical imaging performance. Based on these insights, we proposed an integrated optical–structural optimization strategy that reduces the internal cavity volume adjacent to the first lens, simultaneously increasing the first lens thickness and the curvature of its internal surface. This strategy both reduces water vapor volume and elevates the temperature of potential condensation zones. The optimized module exhibits markedly improved resistance to condensation compared with the baseline design in the experiment, raising the critical condensation threshold from a sudden temperature drop of 42 °C to over 60 °C. This approach effectively mitigates condensation under harsh environmental conditions without additional cost. Our simple yet effective design is broadly applicable to diverse automotive camera module architectures, thereby enhancing system reliability and improving the overall safety of autonomous driving.

  • Highly Sensitive CO/Oâ‚‚ Sensor for In Situ Measurement in Industrial Heating Furnace Based on Calibration-Free Wavelength Modulation Spectroscopy

    by Chao Huang, Xiangchen Kong, Chun Li, Yan Li, Haoyun Wei

    Continuous catalytic reforming heating furnace is a large-scale system that provides consistent and stable heat support for catalytic reactions. Real-time, in-situ and simultaneous measurement of carbon monoxide (CO) and oxygen (O2) is essential for optimizing its performance. Here, we present a highly sensitive CO/O2 sensor based on calibration-free wavelength modulation spectroscopy (WMS) for application in a 10-meter-long large-scale continuous reforming heating furnace. The first harmonic-normalized second harmonic WMS (WMS-2f/1f) technique and a time-division-multiplexed strategy were employed to address the challenges of harsh industrial environments. A Single-ended configuration with a retro-reflector and a through-hole parabolic mirror effectively doubled the optical path while simplifying the sensor setup, providing a novel solution for monitoring large-scale heating furnaces. The sensor demonstrated detection limits of 0.3 ppm and 0.04% for CO and O2, respectively, achieving high sensitivity at high temperature around 850 K. Long-term in-situ monitoring confirmed the sensor’s reliability in detecting CO and O₂ concentrations. Observational data further revealed several instances of incomplete combustion process lasting for 1-2 hours, caused by fluctuations in fuel supply. These findings highlight the significant potential of the proposed laser absorption-based gas sensor to enhance heating furnace control, contributing to improved economic efficiency, environmental protection, and operational safety.


  • Open Access

    Improvement of gain and spatial resolution for impulsive stimulated Brillouin scattering microscopy

    by Taoran Le, Jiarui Li, Haoyun Wei, Yan Li


  • Reducing tilt-to-length coupling with imaging system and photodetector tilt in transponder-type interferometer

    by Xiaoyang Lin, Henglin Mu, Xin Xu, Yidong Tan, Haoyun Wei, Yan Li

    A transponder-type laser interferometer is built to simulate tilt-to-length coupling in spaceborne gravitational wave interferometers. Intentional tilt of the detector and imaging system are used to suppress first-order and second-order TTL coupling.

  • Six-Degrees-of-Freedom Test Mass Readout via Optical Phase-Locking Heterodyne Interferometry

    by Xin Xu, Jinsong Liu, Henglin Mu, Yan Li, Yidong Tan

    Accurate position and posture measurements of the freely-falling test mass are crucial for the success of spaceborne gravitational wave detection missions. This paper presents a novel laboratory-developed test mass motion readout that utilizes quadrant photodetectors to measure the translation and tilt of a test mass. Departing from conventional methods like Zeeman effect or AOM frequency shift modulation, the readout system employs the phase locking of two lasers to generate the dual-frequency heterodyne source. Notably, the out-of-loop sensitivity of the phase locking reaches below 30 pm/Hz1/2 within the frequency band of 1 mHz and 10 Hz. The system comprises three measurement interferometers and one reference interferometer, featuring a symmetric design that enables measurements of up to six degrees of freedom based on polarization-multiplexing and differential wavefront sensing. Ground-simulated experimental results demonstrate that the proposed system has achieved a measurement sensitivity of 4 pm/Hz1/2 and 2 nrad/Hz1/2 at 1 Hz, a resolution of 5 nm and 0.1 μrad, a range of 200 μm and 600 μrad, respectively. These findings showcase the system’s potential as an alternative method for precisely monitoring the motion of test masses in spaceborne gravitational wave detection missions and other applications requiring accurate positioning and multi-degrees-of-freedom sensing.


  • Open Access

    Speed of sound measurement and mapping in transparent materials by impulsive stimulated Brillouin microscopy

    by Taoran Le, Jiarui Li, Haoyun Wei, Yan Li

    Impulsive stimulated Brillouin scattering (ISBS) is a variant of stimulated Brillouin scattering, which can overcome the shortcomings of the long acquisition time of traditional Brillouin microscopy. We introduce the difference between ISBS and other Brillouin microscopies in calculating longitudinal modulus. The Brillouin frequency shift obtained by ISBS is only related to the system parameters and the speed of sound (SOS) in the sample, not to the refractive index. Non-contact SOS measurement of homogeneous samples is an important application of Brillouin scattering, used in the early study of Brillouin spectroscopy and the mechanical properties of liquids. However, the measurement requires prior knowledge of the sample refractive index, which limits the measurement of the unknown refractive index sample. Here, we propose a method to measure the SOS based on ISBS, which in principle avoids the need for refractive index parameters. The SOS of several liquids are measured and compared with the standard values. The mean relative standard deviation is 1.13%. Moreover, we measure the SOS of a mixture of ethanol and water to demonstrate an application of measuring SOS without refractive index information. We also demonstrate the high spatial resolution of ISBS with a methanol-filled PDMS sample.


  • Cavity-enhanced dual-comb spectroscopy with wide spectral band tuning

    by Bocheng Tang, Weipeng Zhang, Minjian Lu, Chao Huang, Yan Li, Haoyun Wei

    Cavity-enhanced dual-comb spectroscopy holds significant research value by combining the high sensitivity of cavity enhancement and dual-comb high resolution and rapid measurement. However, due to the presence of intracavity dispersion, the insufficient coupling between the enhancement cavity and the optical frequency comb restricts the measurement bandwidth of the system, making it unable to provide abundant spectral information of the sample. To overcome this limitation, we propose a cavity-enhanced dual-comb spectroscopy with wide spectral band tuning by a single-point locking tuning scheme, which achieves a tuning capability of over 9 THz at the central wave number of 6400 cm−1. This represents a significant improvement compared to the untuned cavity-enhanced spectrum, increasing the measurable bandwidth by 2.5 times. We verified the capability of the scheme by measuring the rovibrational spectrum of CO2 in various frequency bands within the 6250–6550 cm−1 range. In each tuned frequency band, we achieved an enhancement factor of ∼950, signal-to-noise ratio (SNR > 600) in 30 s, and resolution of 250 MHz. The cavity-enhanced dual-comb spectroscopy with wide spectral band tuning holds promise for potential applications in fields such as trace gas analysis and respiratory diagnostics.


  • High-speed impulsive stimulated Brillouin microscopy

    by Jiarui Li, Taoran Le, Hongyuan Zhang, Haoyun Wei, Yan Li

    Brillouin microscopy, which maps the elastic modulus from the frequency shift of scattered light, has evolved to a faster speed for the investigation of rapid biomechanical changes. Impulsive stimulated Brillouin scattering (ISBS) spectroscopy has the potential to speed up measurement through the resonant amplification interaction from pulsed excitation and time-domain continuous detection. However, significant progress has not been achieved due to the limitation in signal-to-noise ratio (SNR) and the corresponding need for excessive averaging to maintain high spectral precision. Moreover, the limited spatial resolution also hinders its application in mechanical imaging. Here, by scrutinizing the SNR model, we design a high-speed ISBS microscope through multi-parameter optimization including phase, reference power, and acquisition time. Leveraging this, with the further assistance of the Matrix Pencil method for data processing, three-dimensional mechanical images are mapped under multiple contrast mechanisms for a millimeter-scale polydimethylsiloxane pattern immersed in methanol, enabling the identification of these two transparent materials without any contact or labeling. Our experimental results demonstrate the capability to maintain high spectral precision and resolution at a sub-millisecond integration time for one pixel. With a two-order improvement in the speed and a tenfold improvement in the spatial resolution over the state-of-the-art systems, this method makes it possible for ISBS microscopes to sensitively investigate rapid mechanical changes in time and space.