XLXuan Li

Xuan Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Xuan Li has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Sensitivity-Based Rolling Operational Reliability Evaluation Method Following the Changing Available Generation Capacity of Renewable Energies

    by Xuan Li, Kaigui Xie, Changzheng Shao, Bo Hu, Wei Huang, Congcong Pan, Xiong Du

    Power system operation reliability evaluation is performed in advance with the predicted value of renewable energy outputs because of the time-consuming evaluation process. However, forecasts of renewable energy outputs are continuously updated during power system operation, leading to the requirement for rolling evaluation to maintain accurate system reliability. In this paper, an efficient within-day rolling operational reliability evaluation based on the sensitivity of power system reliability with respect to the available generation capacity of renewable energies is proposed. This approach can be used to obtain the reliability indices by correcting the previous reliability evaluation results when the renewable energy outputs fluctuate slightly. First, the transmission line status dictionary method and the load feasible region (LFR) approach are combined in this paper to construct an LFR-based Monte Carlo Simulation method for reliability evaluation. Then, an approximate distance method for load shedding calculation is proposed to establish the linear polynomial relationship between the load shedding and the available generation capacity of renewable energies. Finally, the sensitivity of the reliability with respect to the available generation capacity of renewable energies is established based on the proposed linear polynomial. Case studies were performed to evaluate the efficiency and scalability of the proposed methods.


  • A Region-Based Approach for the Operational Reliability Evaluation of Power Systems With Renewable Energy Integration

    by Xuan Li, Kaigui Xie, Changzheng Shao, Bo Hu

    Power system operational reliability evaluation is computationally time-consuming due to the need to analyze numerous system states resulting from uncertain renewable energies and loads as well as random outages of components. This article presents a load feasible region (LFR) approach to accelerate the process of operational reliability evaluation. The LFR of each state, which is defined as a polyhedron in the load space, can be built in advance offline. The inner points of the LFR correspond to the loads that can be satisfied under the system operational constraints. Then, the preestablished LFR can be corrected with little computing effort considering the renewable energy fluctuation during the operation phase. The optimal load shedding under each state can be obtained directly by calculating the minimum Manhattan distance to the LFR's boundary. Multiple application examples are presented to demonstrate the efficiency and scalability of the proposed region-based approach.


  • Optimal Layout Model of Distribution Automation Terminals Based on Improved Quantum Genetic Algorithm

    by Weichen Liang, Zhiyu Zhao, Yajuan Wang, Xuan Li, Bowen Liu, Xu Zhang

    The reasonable planning of the distribution automation terminal is an important means to improve the reliability of the power supply of the system, and belongs to the problem of distribution network planning. At present, the planning of distribution automation terminals mostly relies on the subjective experience of technicians and lacks objective theoretical support. Therefore, it is of great significance to carry out research on the optimal layout of distribution automation terminals. With the goal of improving the reliability of system power supply, this paper proposes an optimized layout model of power distribution terminals based on an improved quantum genetic algorithm. The objective function of the model is the comprehensive cost of the system including equipment investment costs and power outage costs within the service life of the equipment, and considers the constraints of power supply reliability and power flow constraints. The simulation algorithm verification shows that the model has achieved a good optimization effect.


  • Open Access

    Wind-Thermal-CSP Bundling Model With an Adjustable Heat Storage Strategy for CSP Stations

    by Xuan Li, Xuebin Wang, Fan Li, Tao Niu, Guoqiang Lu, Yue Sun, Wei Huang, Bo Hu, Kaigui Xie

    The installed capacity of renewable energy has continued to increase in recent years, causing excess power to be transmitted to neighboring provinces by DC transmission with wind and thermal power bundling. However, with increasing coal cost and decreasing investment benefit of thermal power, the economic benefit of thermal power investment has decreased. Therefore, this paper proposes a method that replaces the thermal power unit with renewable energy to assume the peak regulating function of the power system. First, a novel heat storage strategy for concentrating solar power (CSP) stations is established. On this basis, the CSP station is included in the wind-thermal bundling model to replace the peak regulating function of some thermal power units, and the planning method of wind-thermal-CSP bundling with an adjustable heat storage strategy is developed. By adjusting the heat storage strategy and comparing the economic parameters under the different strategies, the optimal ratio of the installation of different powers is obtained.


  • Study on fault ride-through capability of wind farm integration using MMC-HVDC

    by Li Xuan, Song Qiang, Liu Wenhua, Ma Yulong

    Due to various advantages, high voltage direct current transmission based on voltage source converter (VSC-HVDC) is gradually coming into practice. It realizes the independent control of both active and reactive power, and has a good dynamic ability of reactive power support. Moreover, if used in wind power transmission, VSC-HVDC decouples the wind farm and the AC grid, which effectively enhances the fault ride-through (FRT) capability of wind power system. There are mainly three VSC circuits for HVDC application at present: HVDC Light of ABB, HVDC Plus of SIMENS, and alternate-arm multilevel converter (A2MC) of Alstom. Schemes from ABB and SIMENS have been widely used, which both apply VSC for ac/dc conversion. HVDC Light uses two-level converter with serial structure of insulated gate bipolar transistors (IGBT), which has advantages like small volume, light weight, and simple control of converter arm. However, it also has some disadvantages, such as more switching loss, higher harmonics in output power, and difficulty in implementing synchronous driving technology for serial IGBTs. HVDC Plus uses modular multilevel converter (MMC) topology, which has obvious advantages in reducing switching loss, lowering harmonic content, upgrading capacity, and managing fault problems. Besides that, MMC has shown superiority in improving FRT capability of wind power system, as studied in the paper. For large-scale wind farm integrated through VSC-HVDC system, when a short-circuit fault occurs in AC grid, the grid-side inverter station transmits less power while there is no change in wind power, which leads to imbalance of power in HVDC system, rise of dc voltage, and disturbances in wind farm. Worse still, the whole HVDC system may collapse under more serious conditions. Converter station built in MMC topology can improve the fault characteristics of wind farm integrated through VSC-HVDC system, and alleviate its disturbances after fault. The paper briefly introduces the basic principles and method of choosing the capacitors of traditional two-level VSC circuit and MMC circuit. To study on FRT problem for wind farm integrated through VSC-HVDC system, a two-terminal VSC-HVDC simulation model of doubly-fed wind farm connected to AC grid respectively through MMC station and traditional VSC station is established in PSCAD/EMTDC, and control strategy of each part is discussed. When there is a three-phase short-circuit fault in AC grid, the FRT capability of VSC-HVDC system with wind farm that integrates through two different schemes is analyzed, and control effects of prevalent FRT method on the wind power system under the two schemes are compared, thus obtaining the influence of converter station built in MMC topology on FRT capability of wind farm integrated through VSC-HVDC system. Capacitors in MMC modules play a crucial role in enhancing the system's FRT capability. The conclusions can provide reference for promoting application of MMC in VSC-HVDC system for transmitting wind power.