ZLZhengwei Li

Zhengwei Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zhengwei Li has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Microforce Measurement Device Based on Multistage Optical Amplification

    by Zhengwei Li, Zhendan Zhang, Long Cheng, Muyuan Ma

    Micro-force measurement devices are widely used in diverse fields such as pharmaceuticals, biomedicine, and precision manufacturing. However, existing systems suffer from limitations including low accuracy, poor linearity, structural complexity, and limited working range. This paper proposes a novel laser-based micro-force measurement system integrating multi-stage optical amplification with Transformer-based residual learning. The design employs a compact three-mirror structure that amplifies angular displacement through consecutive reflections, enabling micron-scale deformation detection under forces as low as 55 μN while maintaining a wide measurement range of 0-1 N. A hybrid algorithm combining grayscale centroid and Gaussian fitting achieves sub-pixel laser spot localization at 0.05 px precision. Further enhanced by a Transformer-based residual learning framework that processes temporal grayscale sequences, the system reduces steady-state noise by 19.9%. The system also exhibits excellent linearity, achieving a linear fit coefficient (R2) of 0.9997. Experimental validation through continuous water droplet experiments confirms the system’s real-time micro-force variation measurement capacity, validating its dynamic performance. The proposed system provides a compact, high-precision solution for applications such as pharmaceutical dosage control and nanomaterial mechanical testing.

  • A Tactile-Proximity Dual-Mode Photoelectric Sensor: Implementation and Applications

    by Xinpan Meng, Long Cheng, Zhengwei Li

    Tactile and proximity sensing is essential for robotic tasks involving human-robot interaction (HRI) and manipulation. However, existing dual-mode sensors often face challenges such as environmental interference, large sizes, and task-specific limitations. This study proposes a dual-mode photoelectric sensor that integrates tactile and proximity sensing. The tactile sensing mechanism is based on a variable optical path structure, while the proximity sensing relies on the surface light reflection. The sensor exhibits a high sensitivity (up to 1.12 V/N), compactness (4 mm thickness), and desirable stability with a drift of less than 1% over 8,000 repetitive cycles under pressures ranging from 0 to 63 kPa. A general tactile-proximity servoing framework is also proposed for the dual-mode sensor array which enables tactile servoing, proximity servoing and hybrid tactile-proximity servoing. Under this framework, parameters can be flexibly adjusted to adapt to different servoing tasks including position and orientation control of the robotic arm's end-effector. In more complex robotic tasks, a real-time fruit ripeness classification method is developed based on the proposed sensor. Using the proposed TPNet, the classification method can achieve an accuracy of 94.4% in a four-level tomato ripeness classification task during grasping.


  • FOCERS: An Ultrasensitive and Robust Soft Optical 3D Tactile Sensor

    by Zhengwei Li, Long Cheng, Zeyu Liu, Jiachen Wei, Yifan Wang

    Soft optical sensors, characterized by excellent stability, strong anti-interference ability, and rapid response, are particularly suitable for exploring unknown environments. However, the low sensitivity and large size of optical tactile sensors have limited their widespread application. This study presents an ultrasensitive, highly linear, and highly robust three-dimensional (3D) tactile sensor based on a Foldable Optical Circuit Embedded in Rigid-Soft-coupled (FOCERS) structure. This sensor exhibits a high sensitivity of 1228.7 kPa −1 under normal pressure of 5 kPa, a super high sensitivity of 7399.5 kPa −1 under a sheer pressure of 1.5 kPa, and a fast response time of 5 ms. Under normal pressure conditions, the sensors exhibited high linearity performance across the entire sensing range, with linearity reaching up to 95.3%. The rigid-soft-coupled structure enhances the robustness and overload resistance of the sensor (withstanding 50 times the sensing range). Demonstrations show that the FOCERS structure can detect minute pressure variations (induced by sesame seeds) and withstand extreme pressures (such as being run over by a car). Furthermore, we designed a joystick based on FOCERS for force detection in human–machine interactions. This study provides a new structure for optical sensors to increase both sensitivity and robustness, and also provides a convenient way to fabricate 3D tactile sensors.


  • A Compact Dual-Core Waveguide Bending Sensor for Embodied Joint Angle Measurement

    by Zeyu Liu, Long Cheng, Zhengwei Li, Xiao Li, Jiachen Wei, Pengpeng Feng

    Bending sensors are extensively employed for joint angle measurement across various applications, including human–machine interaction (HMI), embodied intelligent systems, sports performance analysis, and rehabilitation therapy. Compared to video-based methods, wearable soft bending sensors offer broader applicability and are immune to occlusion. This article presents a compact dual-core waveguide bending sensor specifically designed for embodied joint angle measurement. Building upon prior tri-core research, the enhanced sensor leverages optical frequency for multichannel signal coupling and decoupling, enabling a more compact design. This advancement facilitates finger joint angle detection while significantly improving measurement capabilities. The proposed sensor consists of two detection core segments with distinct optical characteristics. Each segment contains two semi-cores of different colors to determine the bending direction. This design achieves compactness and reduces power consumption. The sensor exhibits excellent linearity, remarkable stability, and an average sensitivity of 0.17 dB/deg over a range of 0$^\circ$ to 90$^\circ$ in both directions. In addition, a bidirectional mamba neural network (BMNN) light signal decoupling algorithm is developed to map short-time optical signals to joint angles, achieving a cross-subject joint angle measurement error of 0.4$^\circ$. This advancement significantly enhances existing joint angle sensors, addressing challenges of reliability and accuracy in joint angle measurement. It holds the potential to advance fields reliant on precise human movement analysis, facilitating more accurate HMIs and the development of universally applicable embodied intelligent systems.


  • A Fuzzy-Encoded Dual-Modal Soft Glove for Gesture and Grasping Object Classification

    by Zeyu Liu, Long Cheng, Houcheng Li, Muyuan Ma, Haoyu Zhang, Zhengwei Li, Zhenghua Ma, Jiachen Wei

    Human-machine interaction technologies are crucial for enhancing human capabilities in the digital world. The hand, as a primary interaction tool, conveys information through gestures and tactile signals. With advancements in flexible electronics and fuzzy systems, it is now possible to achieve interpretable and accurate interactions using hand gestures and tactile information. This paper introduces a fuzzy-encoded, dual-modal soft glove applied to gesture and grasping object classification. The glove, featuring 10 soft pressure sensors and 6 soft bending sensors, is compactly designed and exhibits excellent sensitivity, with average sensitivities of 133 N$^{-1}$ for soft pressure sensors and 13deg$^{-1}$ for soft bending sensors. The Fuzzy Mamba Encoding (FuME) classification algorithm, inspired by the interpretability and uncertainty resilience of fuzzy systems and the fitting ability of state-space models, was developed. To the best of our knowledge, this work is the first to combine the Mamba structure with fuzzy intelligent systems. Applied to gesture and grasping object classifications, the glove achieved average accuracies of 96.3% and 94.9%, respectively. The fuzzy encoding leverages membership vectors provided by experts to enhance interpretability. These results demonstrate the glove's effectiveness in signal recording and processing and highlight the powerful synergy between flexible electronic technologies and fuzzy systems.


  • A Pressure-Based High-Quality Wrist Pulse Measurement System With an Application in Emotion Analysis

    by Zeyu Liu, Long Cheng, Zhengwei Li

    Wrist pulse contains much information about human beings, a typical pulse wave contains four significant morphological features which are related to the cardiovascular system and can be used for disease diagnosis. A high-quality wrist pulse measurement system is essential for the medical application of wrist pulses. In this work, a high-quality wrist pulse measurement system based on a pressure sensor is proposed. The measurement system has a maximum signal-to-noise ratio (SNR) of 53.44 dB and a satisfactory ability to resist environmental interferences. The system is applied to measure the wrist pulse signals of seven participants under different emotions and the signal quality is assessed in three signal quality indices (SQIs): the skewness, the kurtosis, and the perfusion index. The collected dataset presents better performance in all three SQIs than the DEAP dataset. The measured high-quality wrist pulse data are applied in emotion classification by an LSTM-GRU Boosting neural network. The emotion classification accuracy is 89.71% in valence and 80.06% in arousal. We also find features extracted by the proposed neural network have a strong connection with three morphological features of the wrist pulse, and we show the medical implication of these three morphological features with emotion.


  • Decoding Electromyographic Signal With Multiple Labels for Hand Gesture Recognition

    by Yongxiang Zou, Long Cheng, Lijun Han, Zhengwei Li, Luping Song

    Surface electromyography (sEMG) is a significant interaction signal in the fields of human-computer interaction and rehabilitation assessment, as it can be used for hand gesture recognition. This paper proposes a novel MLHG model to improve the robustness of sEMG-based hand gesture recognition. The model utilizes multiple labels to decode the sEMG signals from two different perspectives. In the first view, the sEMG signals are transformed into motion signals using the proposed FES-MSCNN (Feature Extraction of sEMG with Multiple Sub-CNN modules). Furthermore, a discriminator FEM-SAGE (Feature Extraction of Motion with graph SAmple and aggreGatE model) is employed to judge the authenticity of the generated motion data. The deep features of the motion signals are extracted using the FEM-SAGE model. In the second view, the deep features of the sEMG signals are extracted using the FES-MSCNN model. The extracted features of the sEMG signals and the generated motion signals are then fused for hand gesture recognition. To evaluate the performance of the proposed model, a dataset containing sEMG signals and multiple labels from 12 subjects has been collected. The experimental results indicate that the MLHG model achieves an accuracy of $99.26\%$ for within-session hand gesture recognition, $78.47\%$ for cross-time, and $53.52\%$ for cross-subject. These results represent a significant improvement compared to using only the gesture labels, with accuracy improvements of $1.91\%$ , $5.35\%$ , and $5.25\%$ in the within-session, cross-time and cross-subject cases, respectively.


  • Intentional Blocking Based Photoelectric Soft Pressure Sensor with High Sensitivity and Stability

    by Zhengwei Li, Long Cheng, Zeyu Liu

    Soft pressure sensors have recently attracted considerable attention because of their applications in human–machine interface, soft robotics, and prosthetics. However, there remain some challenges in achieving satisfactory performance (e.g., high sensitivity, wide sensing range, high stability) for soft pressure sensors. This article reports an intentional blocking based photoelectric pressure sensor. Two different blocking methods are investigated: the single-row-pyramid blocking and the double-row-pyramid blocking. The sensor has a simple structure, which is made of a light-emitting diode, photosensitive element, and silicone sensor shell. Experiments demonstrate that the sensor has a high sensitivity (the maximum sensitivity is 48.07 kPa −1 , and the minimum measurement pressure is 0.8 Pa), large pressure-sensing range (the sensing range is up to 120 kPa), superior stability (a drift about 0.4% over 12,130 repetitive cycles at 0–80 kPa), low drift (< ±0.2% in different 3-day testing), negligible hysteresis, and high signal-to-noise ratio (over 55 dB). By mounting the pressure sensor at the end of a robotic arm, the robot can detect subtle collisions (such as touching a balloon through a pinpoint). In addition, this article fabricates a tactile glove based on the proposed pressure sensor and shows the application of this glove for music playing and object weighing. This study provides a new structure for photoelectric sensors to increase sensitivity and also provides a more convenient way to fabricate photoelectric pressure sensors.