Seung Su Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Seung Su Kim has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Woochol Joseph Choi
Injury Prevention and Biomechanics Laboratory, Department of Physical Therapy, Yonsei University, Wonju, South Korea
3 shared publications - Chung-Hwi Yi
Department of Physical Therapy, College of Software and Digital Healthcare Convergence, Yonsei University, Wonju, Korea
2 shared publications - Kitaek Lim
Injury Prevention and Biomechanics Laboratory, Department of Physical Therapy, Yonsei University, Wonju, Korea
2 shared publications Bpt
1 shared publication- Hye-Seon Jeon
Department of Physical Therapy, The Graduate School, Yonsei University, Wonju, Korea
1 shared publication J.H. Kim
Institute of Physics and Applied Physics, Yonsei University, 134 Shinchon-dong, Sudaemoon-ku, Seoul 120-749, South Korea
1 shared publication
Latest Publications
- 1 February 2026
- Published by Human Kinetics in Journal of Applied Biomechanics
- Vol. 42 (1) , 22-30
Correlations Between the Trochanteric Soft Tissue Stiffness and the Pelvis Stiffness During Sideways Falls
The pelvis and trochanteric soft tissue stiffness influence hip impact force during falls. We examined potential relationships between the stiffness values acquired from different methodologies. Twenty-six individuals simulated sideways falls. During trials, force-deformation data of the trochanteric soft tissue were recorded, then fitted to polynomial and exponential functions. Stiffness was determined as a slope of the tangent line at maximum deformation ( K s_1st , K s_2nd , and K s_exp ) and at 0.4 N ( K s_2nd_0.4 N , K s_exp_0.4 N ). Similarly, force-deformation data of the pelvis were fitted exponentially to determine the pelvis stiffness at peak impact force ( K b ). We also used a clinical device to measure the trochanteric soft tissue stiffness ( K s_myoton ). Correlation and regression analyses were performed. The K b was correlated with K s_1st and K s_2nd ( P < .05) and decreased 1.7 and 0.7 kN/m for every 1 kN/m increase in K s_1st and K s_2nd , respectively ( R 2 = .23 and R 2 = .21), but no variables were correlated with the K s_myoton ( P > .05). When normalized, however, both K b and K s_myoton were correlated with K s_1st and K s_2nd ( P < .05). These findings provide insights into hip impact dynamics, suggesting that trochanteric soft tissue stiffness measured with a clinical device may serve as a predictor of pelvis stiffness during falls.
- 1 February 2026
- Published by Human Kinetics in Journal of Applied Biomechanics
- Vol. 42 (1) , 22-30
Correlations Between the Trochanteric Soft Tissue Stiffness and the Pelvis Stiffness During Sideways Falls
The pelvis and trochanteric soft tissue stiffness influence hip impact force during falls. We examined potential relationships between the stiffness values acquired from different methodologies. Twenty-six individuals simulated sideways falls. During trials, force-deformation data of the trochanteric soft tissue were recorded, then fitted to polynomial and exponential functions. Stiffness was determined as a slope of the tangent line at maximum deformation ( K s_1st , K s_2nd , and K s_exp ) and at 0.4 N ( K s_2nd_0.4 N , K s_exp_0.4 N ). Similarly, force-deformation data of the pelvis were fitted exponentially to determine the pelvis stiffness at peak impact force ( K b ). We also used a clinical device to measure the trochanteric soft tissue stiffness ( K s_myoton ). Correlation and regression analyses were performed. The K b was correlated with K s_1st and K s_2nd ( P < .05) and decreased 1.7 and 0.7 kN/m for every 1 kN/m increase in K s_1st and K s_2nd , respectively ( R 2 = .23 and R 2 = .21), but no variables were correlated with the K s_myoton ( P > .05). When normalized, however, both K b and K s_myoton were correlated with K s_1st and K s_2nd ( P < .05). These findings provide insights into hip impact dynamics, suggesting that trochanteric soft tissue stiffness measured with a clinical device may serve as a predictor of pelvis stiffness during falls.
- Open Access
- 20 May 2021
- Published by Korean Research Society of Physical Therapy in Physical Therapy Korea
- Vol. 28 (2) , 154-160
Effect on the Center of Pressure of Vision, Floor Condition, and the Height of Center of Mass During Quiet Standing
Seung-su Kim, PT, BPT, Kitaek Lim, PT, BPT, Woochol Joseph Choi, PT, PhD. Phys. Ther. Korea 2021;28:154-60. https://doi.org/10.12674/ptk.2021.28.2.154
- 20 May 2021
- Published by Korean Research Society of Physical Therapy in Physical Therapy Korea
- Vol. 28 (2) , 154-160
Open AccessEffect on the Center of Pressure of Vision, Floor Condition, and the Height of Center of Mass During Quiet Standing
Seung-su Kim, PT, BPT, Kitaek Lim, PT, BPT, Woochol Joseph Choi, PT, PhD. Phys. Ther. Korea 2021;28:154-60. https://doi.org/10.12674/ptk.2021.28.2.154
- 1 December 2002
- Published by Elsevier in Thin Solid Films
- Vol. 420-421, 19-22
Photoelectric and optical properties of pentacene films deposited on n-Si by thermal evaporation
- 1 December 2002
- Published by Elsevier in Thin Solid Films
- Vol. 420-421, 19-22
Photoelectric and optical properties of pentacene films deposited on n-Si by thermal evaporation