Semra Bakkaloglu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Semra Bakkaloglu has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- James Lawrence France
Earth Sciences Department, Royal Holloway University of London, Egham, Surrey TW20 0EX, UK
14 shared publications - David Lowry
Department of Earth Sciences, Centre of Climate, Ocean and Atmosphere, Royal Holloway, University of London, Egham TW20 0EQ, United Kingdom
13 shared publications - Rebecca E. Fisher
Department of Earth Sciences, Royal Holloway, University of London, Egham, TW20 0EX, UK
11 shared publications - Camille Yver-Kwok
Laboratoire des Sciences du Climat de l’Environnement (LSCE-IPSL), UMR CNRS-CEA-UVSQ, 91191 Gif-sur-Yvette, France
9 shared publications - Chris Rennick
National Physical Laboratory, Teddington, UK
9 shared publications Euan G. Nisbet
Department of Earth Sciences, Royal Holloway, University of London, UK
9 shared publications
Latest Publications
- Open Access
- 2 November 2026
- Published by Elsevier in Journal of Cleaner Production
- Vol. 584
Environmental and economic assessment of olefin synthesis from waste as an emerging alternative to conventional light olefin production routes
- 2 November 2026
- Published by Elsevier in Journal of Cleaner Production
- Vol. 584
Open AccessEnvironmental and economic assessment of olefin synthesis from waste as an emerging alternative to conventional light olefin production routes
- Open Access
- 6 March 2026
- Published by Springer Nature in Communications Sustainability
- Vol. 1 (1) , 40
Market solutions for decarbonising supply chains in the chemical industry
- 6 March 2026
- Published by Springer Nature in Communications Sustainability
- Vol. 1 (1) , 40
Open AccessMarket solutions for decarbonising supply chains in the chemical industry
- Open Access
- 6 February 2025
- Published by Stockholm University Press in Tellus B: Chemical and Physical Meteorology
- Vol. 77 (1)
Evaluation of Data Processing Strategies for Methane Isotopic Signatures Determined During Near-Source Measurements
Mobile, near-source measurements are broadly used for determining δ13CH4 of individual methane (CH4) emissions sources. To answer the need for robust and comparable measurement methods, we aim to define the best practices to determine isotopic signatures of CH4 sources from atmospheric measurements, considering instrument accuracy and precision. Using the Keeling and Miller-Tans methods, we verify the impact of linear fitting methods, averaging approaches, and for the Miller-Tans method, different background composition. Measurement techniques include Isotope Ratio Mass Spectrometry (IRMS) and Cavity Ring Down Spectroscopy (CRDS). The use of the active AirCore system for sampling, coupled to CRDS for measurement, is examined. Due to their higher precision and accuracy, the chosen data processing strategy does not significantly influence IRMS results. Comparatively lower-precision CRDS measurements are more sensitive to methodological choices. Fitting methods with forced symmetry like Major Axis or Bivariate Correlated Errors and Intrinsic Scatter (BCES) with orthogonal sub-method introduce significant bias in the determined δ13CH4 signatures using measurements from the lower-precision CRDS. The most reliable results are obtained for non-averaged data using fitting methods, which include uncertainties of x- and y-axis values, like York fitting or BCES (Y|X) sub-method, where x is treated as an independent variable. The Ordinary Least Squares method provides sufficiently robust results and can be used to determine δ13CH4 in near-source conditions. The present recommendations are aimed at laboratories measuring δ13CH4 source signatures to encourage consistency in the required methods for data analysis.
- 6 February 2025
- Published by Stockholm University Press in Tellus B: Chemical and Physical Meteorology
- Vol. 77 (1)
Open AccessEvaluation of Data Processing Strategies for Methane Isotopic Signatures Determined During Near-Source Measurements
Mobile, near-source measurements are broadly used for determining δ13CH4 of individual methane (CH4) emissions sources. To answer the need for robust and comparable measurement methods, we aim to define the best practices to determine isotopic signatures of CH4 sources from atmospheric measurements, considering instrument accuracy and precision. Using the Keeling and Miller-Tans methods, we verify the impact of linear fitting methods, averaging approaches, and for the Miller-Tans method, different background composition. Measurement techniques include Isotope Ratio Mass Spectrometry (IRMS) and Cavity Ring Down Spectroscopy (CRDS). The use of the active AirCore system for sampling, coupled to CRDS for measurement, is examined. Due to their higher precision and accuracy, the chosen data processing strategy does not significantly influence IRMS results. Comparatively lower-precision CRDS measurements are more sensitive to methodological choices. Fitting methods with forced symmetry like Major Axis or Bivariate Correlated Errors and Intrinsic Scatter (BCES) with orthogonal sub-method introduce significant bias in the determined δ13CH4 signatures using measurements from the lower-precision CRDS. The most reliable results are obtained for non-averaged data using fitting methods, which include uncertainties of x- and y-axis values, like York fitting or BCES (Y|X) sub-method, where x is treated as an independent variable. The Ordinary Least Squares method provides sufficiently robust results and can be used to determine δ13CH4 in near-source conditions. The present recommendations are aimed at laboratories measuring δ13CH4 source signatures to encourage consistency in the required methods for data analysis.
- Open Access
- 20 January 2025
- Published by Copernicus GmbH
Carbon isotope measurements of methane for UK sources: spatial and temporal changes and implications for inventories and model inputs
The carbon isotopic signature (ð13C) of CH4 fugitive emissions to atmosphere has been measured in downwind plumes from nearly 400 sources in the United Kingdom by the RHUL group since first measurements of the natural gas supply in 1998. The isotopic measurements have the ability to distinguish the main source categories, separating combustion, fossil fuels, waste and agriculture. Further isotopic subdivisions are possible between solid and gaseous fuels, and between different types and methods of waste processing, such that signatures can be assigned to the categories used for the UK reporting to UNFCCC and in production of mapped inventory products.For many source categories the current spread of ð13C signatures is small, such as onshore natural gas distribution at -39.3 ±2.6‰ (171), or landfill sites at -57.1 ±2.5‰ (54). This has allowed production of isotopic prediction maps and an assessment of the changing source mix isotopic signature emitted by the UK, which contributes to long-range transport and eventually the changing signatures recorded at background measurement sites. The predicted ð13C for averaged UK emission of CH4 changed from -50.5‰ in 1990 to -59.3‰ in 2021 based on the most recent NAEI inventory. Approximately 75% of this 13C depletion is explained by changing proportions of the different sources, particularly emissions reduction from coal mining, landfill sites and gas leaks, but 25% is the result of changing signatures within source categories, particularly in gas distribution with the switch from southern North Sea fields to sources further north, and from changes in landfill practice. This signature is depleted by 3‰ compared to the lowest signature calculated by Miller-Tans analysis of multi-year UK background records, suggesting discrepancies between actual emissions and the inventory source mix. Isotopic mass balance of sources to match observations would require additional fossil fuel emissions, unless there are enrichments rather than depletions occurring in other source sectors.Changes to sources in the last decade, particularly within the agricultural sector and agricultural waste, has created added complexities to the sector isotopic separations and potential isotopic enrichments. These include C4 plant supplements to diets of animals such as maize that enriches the eructation in 13C, whereas the grass-fed and sustainable cattle have a tightly constrained eructation ð13C signature of -70.5 ±1.7‰ (14). Even more extreme is the range of signatures generated by the burgeoning ‘green’ biogas industry fed by energy crops such as maize at one end of the spectrum with ð13C up to -35‰ to NH3-mediated CH4 production from chicken waste feedstock with signatures around -80‰. Surveys in 2023 highlighted emissions underestimation and the preponderance of maize use in this expanding sector. New isotopic data changed the assigned sector source signature by +1.5‰.
- 20 January 2025
- Published by Copernicus GmbH
Open AccessCarbon isotope measurements of methane for UK sources: spatial and temporal changes and implications for inventories and model inputs
The carbon isotopic signature (ð13C) of CH4 fugitive emissions to atmosphere has been measured in downwind plumes from nearly 400 sources in the United Kingdom by the RHUL group since first measurements of the natural gas supply in 1998. The isotopic measurements have the ability to distinguish the main source categories, separating combustion, fossil fuels, waste and agriculture. Further isotopic subdivisions are possible between solid and gaseous fuels, and between different types and methods of waste processing, such that signatures can be assigned to the categories used for the UK reporting to UNFCCC and in production of mapped inventory products.For many source categories the current spread of ð13C signatures is small, such as onshore natural gas distribution at -39.3 ±2.6‰ (171), or landfill sites at -57.1 ±2.5‰ (54). This has allowed production of isotopic prediction maps and an assessment of the changing source mix isotopic signature emitted by the UK, which contributes to long-range transport and eventually the changing signatures recorded at background measurement sites. The predicted ð13C for averaged UK emission of CH4 changed from -50.5‰ in 1990 to -59.3‰ in 2021 based on the most recent NAEI inventory. Approximately 75% of this 13C depletion is explained by changing proportions of the different sources, particularly emissions reduction from coal mining, landfill sites and gas leaks, but 25% is the result of changing signatures within source categories, particularly in gas distribution with the switch from southern North Sea fields to sources further north, and from changes in landfill practice. This signature is depleted by 3‰ compared to the lowest signature calculated by Miller-Tans analysis of multi-year UK background records, suggesting discrepancies between actual emissions and the inventory source mix. Isotopic mass balance of sources to match observations would require additional fossil fuel emissions, unless there are enrichments rather than depletions occurring in other source sectors.Changes to sources in the last decade, particularly within the agricultural sector and agricultural waste, has created added complexities to the sector isotopic separations and potential isotopic enrichments. These include C4 plant supplements to diets of animals such as maize that enriches the eructation in 13C, whereas the grass-fed and sustainable cattle have a tightly constrained eructation ð13C signature of -70.5 ±1.7‰ (14). Even more extreme is the range of signatures generated by the burgeoning ‘green’ biogas industry fed by energy crops such as maize at one end of the spectrum with ð13C up to -35‰ to NH3-mediated CH4 production from chicken waste feedstock with signatures around -80‰. Surveys in 2023 highlighted emissions underestimation and the preponderance of maize use in this expanding sector. New isotopic data changed the assigned sector source signature by +1.5‰.
- Open Access
- 19 June 2024
- Published by Elsevier in Cell Reports Sustainability
- Vol. 1 (7)
The role of negative emissions technologies in the UK’s net-zero strategy
- 19 June 2024
- Published by Elsevier in Cell Reports Sustainability
- Vol. 1 (7)
Open AccessThe role of negative emissions technologies in the UK’s net-zero strategy
- Open Access
- 18 March 2024
- Published by Copernicus GmbH
- Vol. 2023, 1-38
Reply on RC1
Stable carbon isotopic signatures of methane emissions are broadly used for methane source identification, apportionment, and global-scale modelling of methane sources and sinks. Thus, accurate and precise isotopic measurements of methane are crucial for methane studies from the local to global scale. To answer the need for robust and verified measurement methods, we aim at defining the best practice to determine isotopic signatures of methane sources, considering accessibility, practicality, costs, accuracy, and precision. Using Keeling and Miller-Tans methods, we verify the impact of linear fitting methods, averaging approaches, and, for Miller-Tans method, differently defined backgrounds. Verification is carried out for measurement sets using Isotope Ratio Mass Spectrometry and Cavity Ring Down Spectroscopy (CRDS). The use of AirCore for sampling, with subsequent measurements by CRDS, is also examined. Different analytical strategies introduce bias in determining isotopic signatures of methane sources, and the crucial role of rejection criteria is demonstrated. Overall, the most robust results are obtained for non-averaged data using fitting methods, which include uncertainties on x- and y-axis values.
- 18 March 2024
- Published by Copernicus GmbH
- Vol. 2023, 1-38
Open AccessReply on RC1
Stable carbon isotopic signatures of methane emissions are broadly used for methane source identification, apportionment, and global-scale modelling of methane sources and sinks. Thus, accurate and precise isotopic measurements of methane are crucial for methane studies from the local to global scale. To answer the need for robust and verified measurement methods, we aim at defining the best practice to determine isotopic signatures of methane sources, considering accessibility, practicality, costs, accuracy, and precision. Using Keeling and Miller-Tans methods, we verify the impact of linear fitting methods, averaging approaches, and, for Miller-Tans method, differently defined backgrounds. Verification is carried out for measurement sets using Isotope Ratio Mass Spectrometry and Cavity Ring Down Spectroscopy (CRDS). The use of AirCore for sampling, with subsequent measurements by CRDS, is also examined. Different analytical strategies introduce bias in determining isotopic signatures of methane sources, and the crucial role of rejection criteria is demonstrated. Overall, the most robust results are obtained for non-averaged data using fitting methods, which include uncertainties on x- and y-axis values.
- Open Access
- 18 March 2024
- Published by Copernicus GmbH
- Vol. 2023, 1-38
Reply on RC1
Stable carbon isotopic signatures of methane emissions are broadly used for methane source identification, apportionment, and global-scale modelling of methane sources and sinks. Thus, accurate and precise isotopic measurements of methane are crucial for methane studies from the local to global scale. To answer the need for robust and verified measurement methods, we aim at defining the best practice to determine isotopic signatures of methane sources, considering accessibility, practicality, costs, accuracy, and precision. Using Keeling and Miller-Tans methods, we verify the impact of linear fitting methods, averaging approaches, and, for Miller-Tans method, differently defined backgrounds. Verification is carried out for measurement sets using Isotope Ratio Mass Spectrometry and Cavity Ring Down Spectroscopy (CRDS). The use of AirCore for sampling, with subsequent measurements by CRDS, is also examined. Different analytical strategies introduce bias in determining isotopic signatures of methane sources, and the crucial role of rejection criteria is demonstrated. Overall, the most robust results are obtained for non-averaged data using fitting methods, which include uncertainties on x- and y-axis values.
- 18 March 2024
- Published by Copernicus GmbH
- Vol. 2023, 1-38
Open AccessReply on RC1
Stable carbon isotopic signatures of methane emissions are broadly used for methane source identification, apportionment, and global-scale modelling of methane sources and sinks. Thus, accurate and precise isotopic measurements of methane are crucial for methane studies from the local to global scale. To answer the need for robust and verified measurement methods, we aim at defining the best practice to determine isotopic signatures of methane sources, considering accessibility, practicality, costs, accuracy, and precision. Using Keeling and Miller-Tans methods, we verify the impact of linear fitting methods, averaging approaches, and, for Miller-Tans method, differently defined backgrounds. Verification is carried out for measurement sets using Isotope Ratio Mass Spectrometry and Cavity Ring Down Spectroscopy (CRDS). The use of AirCore for sampling, with subsequent measurements by CRDS, is also examined. Different analytical strategies introduce bias in determining isotopic signatures of methane sources, and the crucial role of rejection criteria is demonstrated. Overall, the most robust results are obtained for non-averaged data using fitting methods, which include uncertainties on x- and y-axis values.
- Open Access
- 18 March 2024
- Published by Copernicus GmbH
- Vol. 2023, 1-38
Reply on RC2
Stable carbon isotopic signatures of methane emissions are broadly used for methane source identification, apportionment, and global-scale modelling of methane sources and sinks. Thus, accurate and precise isotopic measurements of methane are crucial for methane studies from the local to global scale. To answer the need for robust and verified measurement methods, we aim at defining the best practice to determine isotopic signatures of methane sources, considering accessibility, practicality, costs, accuracy, and precision. Using Keeling and Miller-Tans methods, we verify the impact of linear fitting methods, averaging approaches, and, for Miller-Tans method, differently defined backgrounds. Verification is carried out for measurement sets using Isotope Ratio Mass Spectrometry and Cavity Ring Down Spectroscopy (CRDS). The use of AirCore for sampling, with subsequent measurements by CRDS, is also examined. Different analytical strategies introduce bias in determining isotopic signatures of methane sources, and the crucial role of rejection criteria is demonstrated. Overall, the most robust results are obtained for non-averaged data using fitting methods, which include uncertainties on x- and y-axis values.
- 18 March 2024
- Published by Copernicus GmbH
- Vol. 2023, 1-38
Open AccessReply on RC2
Stable carbon isotopic signatures of methane emissions are broadly used for methane source identification, apportionment, and global-scale modelling of methane sources and sinks. Thus, accurate and precise isotopic measurements of methane are crucial for methane studies from the local to global scale. To answer the need for robust and verified measurement methods, we aim at defining the best practice to determine isotopic signatures of methane sources, considering accessibility, practicality, costs, accuracy, and precision. Using Keeling and Miller-Tans methods, we verify the impact of linear fitting methods, averaging approaches, and, for Miller-Tans method, differently defined backgrounds. Verification is carried out for measurement sets using Isotope Ratio Mass Spectrometry and Cavity Ring Down Spectroscopy (CRDS). The use of AirCore for sampling, with subsequent measurements by CRDS, is also examined. Different analytical strategies introduce bias in determining isotopic signatures of methane sources, and the crucial role of rejection criteria is demonstrated. Overall, the most robust results are obtained for non-averaged data using fitting methods, which include uncertainties on x- and y-axis values.
- Open Access
- 18 March 2024
- Published by Copernicus GmbH
- p. 1-38
Reply on RC1
Stable carbon isotopic signatures of methane emissions are broadly used for methane source identification, apportionment, and global-scale modelling of methane sources and sinks. Thus, accurate and precise isotopic measurements of methane are crucial for methane studies from the local to global scale. To answer the need for robust and verified measurement methods, we aim at defining the best practice to determine isotopic signatures of methane sources, considering accessibility, practicality, costs, accuracy, and precision. Using Keeling and Miller-Tans methods, we verify the impact of linear fitting methods, averaging approaches, and, for Miller-Tans method, differently defined backgrounds. Verification is carried out for measurement sets using Isotope Ratio Mass Spectrometry and Cavity Ring Down Spectroscopy (CRDS). The use of AirCore for sampling, with subsequent measurements by CRDS, is also examined. Different analytical strategies introduce bias in determining isotopic signatures of methane sources, and the crucial role of rejection criteria is demonstrated. Overall, the most robust results are obtained for non-averaged data using fitting methods, which include uncertainties on x- and y-axis values.
- 18 March 2024
- Published by Copernicus GmbH
- p. 1-38
Open AccessReply on RC1
Stable carbon isotopic signatures of methane emissions are broadly used for methane source identification, apportionment, and global-scale modelling of methane sources and sinks. Thus, accurate and precise isotopic measurements of methane are crucial for methane studies from the local to global scale. To answer the need for robust and verified measurement methods, we aim at defining the best practice to determine isotopic signatures of methane sources, considering accessibility, practicality, costs, accuracy, and precision. Using Keeling and Miller-Tans methods, we verify the impact of linear fitting methods, averaging approaches, and, for Miller-Tans method, differently defined backgrounds. Verification is carried out for measurement sets using Isotope Ratio Mass Spectrometry and Cavity Ring Down Spectroscopy (CRDS). The use of AirCore for sampling, with subsequent measurements by CRDS, is also examined. Different analytical strategies introduce bias in determining isotopic signatures of methane sources, and the crucial role of rejection criteria is demonstrated. Overall, the most robust results are obtained for non-averaged data using fitting methods, which include uncertainties on x- and y-axis values.
- Open Access
- 18 March 2024
- Published by Copernicus GmbH
- Vol. 2023, 1-38
Reply on RC1
Stable carbon isotopic signatures of methane emissions are broadly used for methane source identification, apportionment, and global-scale modelling of methane sources and sinks. Thus, accurate and precise isotopic measurements of methane are crucial for methane studies from the local to global scale. To answer the need for robust and verified measurement methods, we aim at defining the best practice to determine isotopic signatures of methane sources, considering accessibility, practicality, costs, accuracy, and precision. Using Keeling and Miller-Tans methods, we verify the impact of linear fitting methods, averaging approaches, and, for Miller-Tans method, differently defined backgrounds. Verification is carried out for measurement sets using Isotope Ratio Mass Spectrometry and Cavity Ring Down Spectroscopy (CRDS). The use of AirCore for sampling, with subsequent measurements by CRDS, is also examined. Different analytical strategies introduce bias in determining isotopic signatures of methane sources, and the crucial role of rejection criteria is demonstrated. Overall, the most robust results are obtained for non-averaged data using fitting methods, which include uncertainties on x- and y-axis values.
- 18 March 2024
- Published by Copernicus GmbH
- Vol. 2023, 1-38
Open AccessReply on RC1
Stable carbon isotopic signatures of methane emissions are broadly used for methane source identification, apportionment, and global-scale modelling of methane sources and sinks. Thus, accurate and precise isotopic measurements of methane are crucial for methane studies from the local to global scale. To answer the need for robust and verified measurement methods, we aim at defining the best practice to determine isotopic signatures of methane sources, considering accessibility, practicality, costs, accuracy, and precision. Using Keeling and Miller-Tans methods, we verify the impact of linear fitting methods, averaging approaches, and, for Miller-Tans method, differently defined backgrounds. Verification is carried out for measurement sets using Isotope Ratio Mass Spectrometry and Cavity Ring Down Spectroscopy (CRDS). The use of AirCore for sampling, with subsequent measurements by CRDS, is also examined. Different analytical strategies introduce bias in determining isotopic signatures of methane sources, and the crucial role of rejection criteria is demonstrated. Overall, the most robust results are obtained for non-averaged data using fitting methods, which include uncertainties on x- and y-axis values.